DOI QR코드

DOI QR Code

Testing of Common Electromagnetic Environments for Risk of Interference with Cardiac Pacemaker Function

  • Tiikkaja, Maria (Safe New Technologies, Finnish Institute of Occupational Health) ;
  • Aro, Aapo L. (Department of Cardiology, Helsinki University Central Hospital) ;
  • Alanko, Tommi (Safe New Technologies, Finnish Institute of Occupational Health) ;
  • Lindholm, Harri (Physical Work Capacity, Finnish Institute of Occupational Health) ;
  • Sistonen, Heli (Physical Work Capacity, Finnish Institute of Occupational Health) ;
  • Hartikainen, Juha E.K. (Heart Center, Kuopio University Hospital and School of Medicine, University of Eastern Finland) ;
  • Toivonen, Lauri (Department of Cardiology, Helsinki University Central Hospital) ;
  • Juutilainen, Jukka (Department of Environmental Science, University of Eastern Finland) ;
  • Hietanen, Maila (Safe New Technologies, Finnish Institute of Occupational Health)
  • 투고 : 2013.04.17
  • 심사 : 2013.06.04
  • 발행 : 2013.09.30

초록

Background: Cardiac pacemakers are known to be susceptible to strong electromagnetic fields (EMFs). This in vivo study investigated occurrence of electromagnetic interference with pacemakers caused by common environmental sources of EMFs. Methods: Eleven volunteers with a pacemaker were exposed to EMFs produced by two mobile phone base stations, an electrically powered commuter train, and an overhead high voltage transmission lines. All the pacemakers were programmed in normal clinically selected settings with bipolar sensing and pacing configurations. Results: None of the pacemakers experienced interference in any of these exposure situations. However, often it is not clear whether or not strong EMFs exist in various work environments, and hence an individual risk assessment is needed. Conclusions: Modern pacemakers are well shielded against external EMFs, and workers with a pacemaker can most often return to their previous work after having a pacemaker implanted. However, an appropriate risk assessment is still necessary after the implantation of a pacemaker, a change of its generator, or major modification of its programming settings.

키워드

피인용 문헌

  1. Elektromagnetische Interferenz von aktiven Herzrhythmusimplantaten im Alltag und im beruflichen Umfeld : Stellungnahme der Deutschen Gesellschaft für Kardiologie (DGK) und der Deutschen Gesellsch vol.13, pp.4, 2013, https://doi.org/10.1007/s12181-019-0335-0
  2. Workers with Active Implantable Medical Devices Exposed to EMF: In Vitro Test for the Risk Assessment vol.6, pp.11, 2013, https://doi.org/10.3390/environments6110119