메탈 DPF 시스템 유동특성 연구

Study on the Flow Characteristics Inside a Metal DPF System

  • 한철희 (한국교통대학교 항공.기계설계학과) ;
  • 전문수 (한국교통대학교 에너지시스템공학과)
  • Han, Cheolheui (Department of Aeronautical and Mechanical Design, Korea National University of Transportation) ;
  • Chon, Munsoo (Department of Energy System Engineering, Korea National University of Transportation)
  • 투고 : 2013.03.08
  • 심사 : 2013.04.22
  • 발행 : 2013.05.31

초록

Unsteady fluid dynamics analysis of flow characteristics inside a Metal DPF system is done using a commercial CAE software, CFD-ACE+. The time profiles of both temperature and pressure of exhaust gas are given as initial conditions. It was found that the position of connecting pipes and the numbering of exhaust gases did not affect the flow uniformity. The presence of a DPF resulted in the significant flow nonuniformity effect on the flow characteristics at the inlet of the DPF. Present results can be applied to the selection of optimal geometry that produces uniform flow characteristics inside a DPF system.