References
- Winklehner A, Goetti R, Baumueller S, Karlo C, Schmidt B, Raupach R, et al. Automated attenuation-based tube potential selection for thoracoabdominal computed tomography angiography: improved dose effectiveness. Invest Radiol 2011;46:767-773 https://doi.org/10.1097/RLI.0b013e3182266448
- Hart D, Wall BF. Radiation exposure of the UK population from medical and dental X-ray Examinations. NRPB-W4. Chilton: NRPB, 2002
- Hur S, Lee JM, Kim SJ, Park JH, Han JK, Choi BI. 80-kVp CT using Iterative Reconstruction in Image Space algorithm for the detection of hypervascular hepatocellular carcinoma: phantom and initial clinical experience. Korean J Radiol 2012;13:152-164 https://doi.org/10.3348/kjr.2012.13.2.152
- Kambadakone AR, Chaudhary NA, Desai GS, Nguyen DD, Kulkarni NM, Sahani DV. Low-dose MDCT and CT enterography of patients with Crohn disease: feasibility of adaptive statistical iterative reconstruction. AJR Am J Roentgenol 2011;196:W743-W752 https://doi.org/10.2214/AJR.10.5303
- Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med 2007;357:2277-2284 https://doi.org/10.1056/NEJMra072149
- Qi W, Li J, Du X. Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT. Korean J Radiol 2009;10:568-574 https://doi.org/10.3348/kjr.2009.10.6.568
- Hwang HJ, Seo JB, Lee JS, Song JW, Kim SS, Lee HJ, et al. Radiation dose reduction of chest CT with iterative reconstruction in image space - Part II: assessment of radiologists' preferences using dual source CT. Korean J Radiol 2012;13:720-727 https://doi.org/10.3348/kjr.2012.13.6.720
- Hwang HJ, Seo JB, Lee JS, Song JW, Kim SS, Lee HJ, et al. Radiation dose reduction of chest CT with iterative reconstruction in image space - Part I: studies on image quality using dual source CT. Korean J Radiol 2012;13:711-719 https://doi.org/10.3348/kjr.2012.13.6.711
- Goo HW. CT radiation dose optimization and estimation: an update for radiologists. Korean J Radiol 2012;13:1-11 https://doi.org/10.3348/kjr.2012.13.1.1
- Moritz JD, Hoffmann B, Sehr D, Keil K, Eggerking J, Groth G, et al. Evaluation of ultra-low dose CT in the diagnosis of pediatric-like fractures using an experimental animal study. Korean J Radiol 2012;13:165-173 https://doi.org/10.3348/kjr.2012.13.2.165
- McCollough CH, Primak AN, Braun N, Kofler J, Yu L, Christner J. Strategies for reducing radiation dose in CT. Radiol Clin North Am 2009;47:27-40 https://doi.org/10.1016/j.rcl.2008.10.006
- Winklehner A, Karlo C, Puippe G, Schmidt B, Flohr T, Goetti R, et al. Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential. Eur Radiol 2011;21:2521-2526 https://doi.org/10.1007/s00330-011-2227-y
- Halliburton SS. Recent technologic advances in multi-detector row cardiac CT. Cardiol Clin 2009;27:655-664 https://doi.org/10.1016/j.ccl.2009.06.007
- Ghetti C, Ortenzia O, Serreli G. CT iterative reconstruction in image space: a phantom study. Phys Med 2012;28:161-165 https://doi.org/10.1016/j.ejmp.2011.03.003
- Schindera ST, Diedrichsen L, Muller HC, Rusch O, Marin D, Schmidt B, et al. Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study. Radiology 2011;260:454-462 https://doi.org/10.1148/radiol.11102217
- Barrett HH, Swindell W. Radiological imaging: the theory of image formation, detection, and processing. New York: Academic Press, 1981
- The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP 2007;37:1-332
- Office for Official Publications of the European Communities. European guidelines on quality criteria for computed tomography. Luxembourg: Office for Official Publications of the European Communities, 1999
- Yu L, Bruesewitz MR, Thomas KB, Fletcher JG, Kofler JM, McCollough CH. Optimal tube potential for radiation dose reduction in pediatric CT: principles, clinical implementations, and pitfalls. Radiographics 2011;31:835-848 https://doi.org/10.1148/rg.313105079
- Leipsic J, LaBounty TM, Mancini GB, Heilbron B, Taylor C, Johnson MA, et al. A prospective randomized controlled trial to assess the diagnostic performance of reduced tube voltage for coronary CT angiography. AJR Am J Roentgenol 2011;196:801-806 https://doi.org/10.2214/AJR.10.5786
- Schindera ST, Nelson RC, Mukundan S Jr, Paulson EK, Jaffe TA, Miller CM, et al. Hypervascular liver tumors: low tube voltage, high tube current multi-detector row CT for enhanced detection--phantom study. Radiology 2008;246:125-132 https://doi.org/10.1148/radiol.2461070307
- Fleischmann D, Boas FE. Computed tomography--old ideas and new technology. Eur Radiol 2011;21:510-517 https://doi.org/10.1007/s00330-011-2056-z
- Mueck FG, Korner M, Scherr MK, Geyer LL, Deak Z, Linsenmaier U, et al. Upgrade to iterative image reconstruction (IR) in abdominal MDCT imaging: a clinical study for detailed parameter optimization beyond vendor recommendations using the adaptive statistical iterative reconstruction environment (ASIR). Rofo 2012;184:229-238 https://doi.org/10.1055/s-0031-1282032
- Moscariello A, Takx RA, Schoepf UJ, Renker M, Zwerner PL, O'Brien TX, et al. Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction techniquecomparison with traditional filtered back projection. Eur Radiol 2011;21:2130-2138 https://doi.org/10.1007/s00330-011-2164-9
Cited by
- Can Sinogram-Affirmed Iterative Reconstruction Improve the Detection of Small Hypervascular Liver Nodules With Dual-Energy CT? vol.38, pp.5, 2014, https://doi.org/10.1097/rct.0000000000000105
- Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis vol.29, pp.4, 2013, https://doi.org/10.1016/s1001-9294(14)60073-0
- Radiation Dose and Imaging Quality of Abdominal Computed Tomography before and after Scan Protocol Adjustment: Single-Institution Experience in Three Years vol.71, pp.6, 2014, https://doi.org/10.3348/jksr.2014.71.6.278
- Attenuation-Based Automatic Kilovoltage Selection and Sinogram-Affirmed Iterative Reconstruction: Effects on Radiation Exposure and Image Quality of Portal-Phase Liver CT vol.16, pp.1, 2015, https://doi.org/10.3348/kjr.2015.16.1.69
- Feasibility Study of Radiation Dose Reduction in Adult Female Pelvic CT Scan with Low Tube-Voltage and Adaptive Statistical Iterative Reconstruction vol.16, pp.5, 2013, https://doi.org/10.3348/kjr.2015.16.5.1047
- Determining and Managing Fetal Radiation Dose from Diagnostic Radiology Procedures in Turkey vol.16, pp.6, 2015, https://doi.org/10.3348/kjr.2015.16.6.1276
- Phantom Study on Dose Reduction Using Iterative Reconstruction in Low-dose Computed Tomography for Lung Cancer Screening vol.71, pp.12, 2013, https://doi.org/10.6009/jjrt.2015_jsrt_71.12.1201
- Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity a vol.16, pp.3, 2013, https://doi.org/10.3348/kjr.2015.16.3.531
- Low Dose Computed Tomography for 3D Planning of Total Hip Arthroplasty: Evaluation of Radiation Exposure and Image Quality vol.39, pp.5, 2013, https://doi.org/10.1097/rct.0000000000000271
- Performances of low-dose dual-energy CT in reducing artifacts from implanted metallic orthopedic devices vol.45, pp.7, 2013, https://doi.org/10.1007/s00256-016-2377-8
- Three-dimensional reconstruction of coronary arteries and plaque morphology using CT angiography – comparison and registration with IVUS vol.16, pp.None, 2016, https://doi.org/10.1186/s12880-016-0111-6
- CT dose reduction: approaches, strategies and results from a province-wide program in Quebec vol.36, pp.2, 2013, https://doi.org/10.1088/0952-4746/36/2/346
- Effective dose estimation for oncological and neurological PET/CT procedures vol.7, pp.1, 2017, https://doi.org/10.1186/s13550-017-0272-5
- Comparison of Chest Pain Protocols for Electrocardiography-Gated Dual-Source Cardiothoracic CT in Children and Adults: The Effect of Tube Current Saturation on Radiation Dose Reduction vol.19, pp.1, 2013, https://doi.org/10.3348/kjr.2018.19.1.23
- Feasibility of radiation dose reduction with iterative reconstruction in abdominopelvic CT for patients with inappropriate arm positioning vol.13, pp.12, 2013, https://doi.org/10.1371/journal.pone.0209754
- Comparison of standard-dose and half-dose dual-source abdominopelvic CT scans for evaluation of acute abdominal pain vol.60, pp.8, 2013, https://doi.org/10.1177/0284185118809544
- Determination of computed tomography number of high-density materials in 12-bit, 12-bit extended and 16-bit depth for dosimetric calculation in treatment planning system vol.18, pp.3, 2013, https://doi.org/10.1017/s1460396919000013
- Validation of CARE kV automated tube voltage selection for PET-CT: PET quantification and CT radiation dose reduction in phantoms vol.8, pp.1, 2013, https://doi.org/10.1186/s40658-021-00373-8