References
-
Aarnio, P., Yli-Tuomi, T., Kousa, A., Mäkelä, T., Hirsikko, A., Hameri, K., Päisänen, M., Hillamo, R., Koskentalo, T., Jantunen, M. (2005) The concentrations and composition of and exposure to fine particles (
$PM_{2.5}$ ) in the Helsinki subway system. Atmospheric Environment 39, 5059-5066. https://doi.org/10.1016/j.atmosenv.2005.05.012 -
Adams, H.S., Nieuwenhuijsen, M.J., Colvile, R.N., McMullen, M.A.S., Khandelwal, P. (2001) Fine particle (
$PM_{2.5}$ ) personal exposure levels in transport microenvironments, London, UK. Science of Total Environment 279, 29-44. https://doi.org/10.1016/S0048-9697(01)00723-9 - Awad, A.H.A. (2002) Environmental study in subway metro stations in Cairo, Egypt. Journal of Occupational Health 44, 112-118. https://doi.org/10.1539/joh.44.112
-
Bachoual, R., Boczkowski, J., Goven, D., Amara, N., Tabet, L., On, D., Leçon-Malas, V., Aubier, M., Lanone, S. (2007) The concentrations and composition of and exposure to fine particles (
$PM_{2.5}$ ) in the Helsinki subway system. Chemical Research in Toxicology 20(10), 1426-1433. https://doi.org/10.1021/tx700093j - Birenzvige, A., Eversole, H., Seaver, M., Francesconi, S., Valdes, E., Kulaga, H. (2003) Aerosol characteristics in a subway environment. Aerosol Science and Technology 37, 210-220. https://doi.org/10.1080/02786820300941
- Branis, M. (2006) The concentration of ambient sources to particulate pollution in spaces and trains of the Prague underground transport system. Atmospheric Environment 40, 348-356. https://doi.org/10.1016/j.atmosenv.2005.09.060
- Cheng, Y.H., Lin, Y.L. (2010) Measurement of Particle Mass Concentrations and Size Distributions in an Underground Station. Aerosol and Air Quality Research 10, 22-29.
-
Cheng, Y.H., Lin, Y.L., Liu, C.C. (2008) Level of
$PM_{10}$ and$PM_{2.5}$ in Taipei rapid transit system. Atmospheric Environment 42, 7242-7249. https://doi.org/10.1016/j.atmosenv.2008.07.011 - Choi, H.W., Hwang, I.J., Kim, S.D., Kim, D.S. (2004) Determination of source contribution based on aerosol number and mass concentration in Seoul subway stations. Journal of Korea Society for Atmospheric Environment 20, 17-31 (in Korean with English abstract).
- Christensson, B., Sternbeck, J., Ancker, K. (2002) Luftburna partiklarapartikelhalter, elementsammansattning och emissionskallor. SL Infrateknik AB (Airborne particles-particle concentrations, elemental composition and emission sources, In Swedish).
- Chrysikou, L.P., Samara, C.A. (2009) Seasonal variation of the size distribution of urban particulate matter and associated organic pollutants in the ambient air. Atmospheric Environment 43, 4557-4569. https://doi.org/10.1016/j.atmosenv.2009.06.033
- Chrysikou, L.P., Gemenetzis, P.G., Samara, C.A. (2009) Winter time size distribution of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) in the urban environment: street-vs rooftop-level measurements. Atmospheric Environment 43, 290-300. https://doi.org/10.1016/j.atmosenv.2008.09.048
- Duan, J., Xi, B., Tan, J., Sheng, G., Fu, J. (2007) Seasonal variation on size distribution and concentration of PAHs in Guangzhou city, China. Chemosphere 67, 614-622. https://doi.org/10.1016/j.chemosphere.2006.08.030
- Fromme, H., Oddoy, A., Piloty, M., Krause, M., Lahrz, T. (1998) Polycyclic aromatic hydrocarbons (PHA) and diesel engine emission (elemental carbon) inside a car and a subway train. Science of Total Environment 217, 165-173. https://doi.org/10.1016/S0048-9697(98)00189-2
- Furuya, K., Kudo, Y., Okinaga, K., Yamuki, M., Takahashi, S., Araki, Y., Hisamatsu, Y. (2001) Seasonal variation and their characterization of suspended particulate matter in the air of subway stations. Journal of Trace and Microprobe Techniques 19(4), 469-485. https://doi.org/10.1081/TMA-100107583
- Grass, D.S., Ross, J.M., Family, F., Barbour, J., Simpson, H.J., Coulibaly, D., Hernandez, J., Chen, Y., Slavkovich, V., Li, Y., Graziano, J., Santella, R.M., Brandt- Rauf, P., Chillrud, S.N. (2010) Airborne particulate metals in the New York City subway: A pilot study to assess the potential for health impacts. Environmental Research 110, 1-11. https://doi.org/10.1016/j.envres.2009.10.006
- Hien, T.T., Thanh, L.T., Kameda, T., Takenaka, N., Bandow, H. (2007) Distribution characteristics of polycyclic aromatic hydrocarbons with particle size in urban aerosols at the roadside in Ho Chi Minh City, Vietnam. Atmospheric Environment 41, 1575-1586. https://doi.org/10.1016/j.atmosenv.2006.10.045
- Johansson, C., Johansson, P.A. (2003) Particulate matter in the underground of Stockholm. Atmospheric Environment 37, 3-9.
- Jung, H.J., Kim, B., Ryu, J., Maskey, S., Kim, J.C., Sohn, J., Ro, C.-U. (2010) Source identification of particulate matter collected at underground subway stations in Seoul, Korea using quantitative single-particle analysis. Atmospheric Environment 44, 2287-2293. https://doi.org/10.1016/j.atmosenv.2010.04.003
- Jung, H.J., Kim, B., Malek, M.A., Koo, Y.S., Jung, J.H., Son, Y.S., Kim, J.C., Kim, H., Ro, C.-U. (2012) Chemical speciation of size-segregated floor dusts and airborne magnetic particles collected at underground subway stations in Seoul, Korea. Journal of Hazardous Material 213-214, 331-340. https://doi.org/10.1016/j.jhazmat.2012.02.006
- Kang, S., Hwang, H., Park, Y., Kim, H., Ro, C.-U. (2008) Chemical compositions of subway particles in Seoul, Korea determined by a quantitative single particle analysis. Environmental Science and Technology 42, 9051-9057. https://doi.org/10.1021/es802267b
- Karlsson, H.L., Nilsson, L., Möller, L. (2005) Subway particles are more genotoxic than street particles and induce oxidative stress in cultured human lung cells. Chemical Research in Toxicology 18, 19-23. https://doi.org/10.1021/tx049723c
- Kim, K.H., Ho, D.X., Jeon, J.S., Kim, J.C. (2012) A noticeable shift in particulate matter levels after platform screen door installation in a Korean subway station. Atmospheric Environment 49, 219-223. https://doi.org/10.1016/j.atmosenv.2011.11.058
-
Kim, K.Y., Kim, Y.S., Roh, Y.M., Lee, C.M., Kim, C.N. (2008) Spatial distribution of particulate matter (
$PM_{10}$ and$PM_{2.5}$ ) in Seoul metropolitan subway station. Journal of Hazardous Material 154, 440-443. https://doi.org/10.1016/j.jhazmat.2007.10.042 - Lee, J.Y., Shin, H.J., Bae, S.Y., Kim, Y.P., Kang, C.H. (2008) Seasonal variation of particle size distributions of PAHs at Seoul, Korea. Air Quality, Atmosphere and Health 1, 57-68. https://doi.org/10.1007/s11869-008-0002-2
- Li, T.T., Bai, Y.H., Liu, Z.R., Li, J.L. (2007) In-train air quality assessment of the railway transit system in Beijing: a note. Transportation Research Part D 12, 64-67. https://doi.org/10.1016/j.trd.2006.11.001
- Mazquiaran, M.A.B., Pinedo, L.C.O.d. (2007) Organic composition of atmospheric urban aerosol: variations and sources of aliphatic and polycyclic aromatic hydrocarbons. Atmospheric Research 85, 288-299. https://doi.org/10.1016/j.atmosres.2007.01.004
- Nieuwenhuijsen, M.J., Gomez-Perrales, J.E., Colvile, R.N. (2007) Levels of particulate air pollution, its elemental composition, determinants and health effects in metro systems. Atmospheric Environment 41, 7995-8006. https://doi.org/10.1016/j.atmosenv.2007.08.002
- Onat, B., Stakeeva, B. (2012) Assessment of fine particulate matters in the subway system of Istanbul. Indoor and Built Environment. Published online.
-
Park, D.U., Ha, K.C. (2008) Characteristics of
$PM_{10}$ ,$PM_{2.5}$ ,$CO_{2}$ and CO monitored in interiors and platforms of subway train in Seoul, Korea. Environment International 34(5), 629-634. https://doi.org/10.1016/j.envint.2007.12.007 - Pfeifer, G.D., Harrison, R.M., Lynam, D.R. (1999) Personal exposures to airborne metals in London taxi drivers and office workers in 1995 and 1996. Science of Total Environment 235(1-3), 253-260. https://doi.org/10.1016/S0048-9697(99)00201-6
- Priest, D., Burns, G., Gorbunov, B. (1998) Dust levels on the London Underground: a health hazard to commuters?, http://62.164.135.147/feat/feat0017.htm.
- Ripanucci, G., Grana, M., Vicentini, L., Magrini, A., Bergamaschi, A. (2006) Dust in the underground railway tunnels of an Italian town. Journal of Occupational and Environmental Hygiene 3, 16-25. https://doi.org/10.1080/15459620500444004
- Salma, I., Weidinger, T., Maenhaut, W. (2007) Time-resolved mass concentration, composition and sources of aerosol particles in a metropolitan underground railway station. Atmospheric Environment 41, 8391-8405. https://doi.org/10.1016/j.atmosenv.2007.06.017
- Seaton, A., Cherrie, J., Dennekamp, M., Donaldson, K., Hurley, J.F., Tran, C.L. (2005) The London underground: dust and hazards to health. Occupational and Environmental Medicine 62, 355-362. https://doi.org/10.1136/oem.2004.014332
- Sitzmann, B., Kendall, M., Watt, J., Williams, I. (1999) Characterisation of airborne particles in London by computer-controlled scanning electron microscopy. Science of Total Environment 241, 63-73. https://doi.org/10.1016/S0048-9697(99)00326-5
- Sohn, J.R., Kim, J.C., Kim, M.Y., Son, Y.S., Sunwoo, Y. (2008) Particulate behavior in subway airspace. Asian Journal of Atmospheric Environment 2(1), 54-59. https://doi.org/10.5572/ajae.2008.2.1.054
-
Son, Y.S., Kang, Y.H., Chung, S.G., Park, H.J., Kim, J.C. (2011) Efficiency evaluation of adsorbents for the removal of VOC and
$NO_{2}$ in an underground subway station. Asian Journal of Atmospheric Environment 5(2), 113-120. https://doi.org/10.5572/ajae.2011.5.2.113
Cited by
- Removal of Particulate Matter Emitted from a Subway Tunnel Using Magnetic Filters vol.48, pp.5, 2014, https://doi.org/10.1021/es404502x
- Installation of platform screen doors and their impact on indoor air quality: Seoul subway trains vol.64, pp.9, 2014, https://doi.org/10.1080/10962247.2014.923350
- The Size-Oriented Particulate Mass Ratios and Their Characteristics on the Seoul Metropolitan Subway Lines vol.10, pp.4, 2016, https://doi.org/10.5572/ajae.2016.10.4.217
- Transient variation of aerosol size distribution in an underground subway station vol.188, pp.6, 2016, https://doi.org/10.1007/s10661-016-5373-5
- Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map vol.32, pp.2, 2016, https://doi.org/10.5572/KOSAE.2016.32.2.216
- Evaluation of airborne fungi and the effects of a platform screen door and station depth in 25 underground subway stations in Seoul, South Korea vol.9, pp.5, 2016, https://doi.org/10.1007/s11869-015-0361-4
- Characteristics of PM2.5, CO2 and particle-number concentration in mass transit railway carriages in Hong Kong vol.39, pp.4, 2017, https://doi.org/10.1007/s10653-016-9844-y
- Particulate Matter (PM10 and PM2.5) in Subway Systems: Health-Based Economic Assessment vol.9, pp.11, 2017, https://doi.org/10.3390/su9112135
- Characteristics of Particulate Matter Concentration and Classification of Contamination Patterns in the Seoul Metropolitan Subway Tunnels vol.33, pp.6, 2017, https://doi.org/10.5572/KOSAE.2017.33.6.593
- Status of particulate matter pollution in urban railway environments vol.17, pp.4, 2018, https://doi.org/10.15250/joie.2018.17.4.303
- 지상과 지하역사의 실내공기질 특성과 외기영향 평가 vol.17, pp.5, 2016, https://doi.org/10.5762/kais.2016.17.5.17
- 수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구 vol.18, pp.2, 2017, https://doi.org/10.5762/kais.2017.18.2.443
- 도시철도 차량 하부의 풍속 및 미세먼지 농도 특징 vol.20, pp.1, 2017, https://doi.org/10.7782/jksr.2017.20.1.11
- A review of traditional and advanced technologies for the removal of particulate matter in subway systems vol.29, pp.2, 2019, https://doi.org/10.1111/ina.12532
- 부산지역 지하역사의 최근 3년간(2015~2017년) PM10과 PM2.5 농도 특성 vol.28, pp.7, 2013, https://doi.org/10.5322/jesi.2019.28.7.581
- Particulate Matter and Influencing Factors in Domestic Elementary Schools vol.36, pp.2, 2013, https://doi.org/10.5572/kosae.2020.36.2.153
- Experimental Investigation of Air Quality in a Subway Station with Fully Enclosed Platform Screen Doors vol.17, pp.14, 2013, https://doi.org/10.3390/ijerph17145213
- Diurnal variation of PM10 concentration in the subway concourse and tunnel vol.19, pp.3, 2013, https://doi.org/10.15250/joie.2020.19.3.231
- Spatial-temporal Characteristics of Particulate Matter in Busan’s Subway Systems vol.36, pp.5, 2020, https://doi.org/10.5572/kosae.2020.36.5.589