DOI QR코드

DOI QR Code

Performance Evaluation of R435A on Refrigeration System of Water Purifiers

R435A를 적용한 정수기 냉동시스템의 성능평가

  • Lee, Yo-Han (Department of Mechanical Engineering, Graduate School, Inha University) ;
  • Kang, Dong-Gyu (Department of Mechanical Engineering, Graduate School, Inha University) ;
  • Choi, Hyun-Joo (Department of Mechanical Engineering, Graduate School, Inha University) ;
  • Jung, Dong-Soo (Department of Mechanical Engineering, Inha University)
  • 이요한 (인하대학교 대학원 기계공학과) ;
  • 강동규 (인하대학교 대학원 기계공학과) ;
  • 최현주 (인하대학교 대학원 기계공학과) ;
  • 정동수 (인하대학교 기계공학과)
  • Received : 2012.09.18
  • Accepted : 2013.02.01
  • Published : 2013.02.28

Abstract

In this study, thermodynamic performance of R435A is examined both numerically and experimentally in an effort to replace HFC134a used in the refrigeration system of domestic water purifiers. Even though HFC134a is used predominantly in such a system these days, it needs to be phased out in the near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of 20%R152a/80%RE170 using actual domestic water purifiers. This mixture is numbered and listed as R435A by ASHRAE recently. Test results show that the system performance with R435A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 to 22 grams, about 50% of HFC134a, the energy consumption of R435A is 11.8% lower than that of HFC134a. The compressor discharge temperature of R435A $8^{\circ}C$ lower than that of HFC134a at the optimum charge. Overall, R435A, a new long term environmentally safe refrigerant, is a good alternative for HFC134a requiring little change in the refrigeration system of the domestic water purifiers.

Keywords

References

  1. United Nations Environment Programme, Montrealprotocolon substances that deplete the ozone layer, Final Act, 1987.
  2. Global Environmental Change Report, A briefanalysis of the Kyoto protocol, Vol. IX, No.24, December,1997.
  3. Kruse, H., The state of the art of the hydrocarbon technology in household refrigeration, Proceedings of the International Conferenceson Ozone Protection Technologies, Washington, DC.,USA, pp.179-188, 1996.
  4. Jung, D., Kim, C., Song, K. and Park, B., Testing of propane/isobutane mixture in domestic refrigerators, International Journal of Refrigeration, Vol.23, No.7, pp.517-527, 2000. https://doi.org/10.1016/S0140-7007(99)00084-5
  5. Jetter, J. J., Smith, N. D., Ratanaphruks K. N., Tufts, M. W. and Delafield, F. R., Evaluation of alternatives for HFC-134a refrigerant in motor vehicle air conditioning, Proceedings of the International Conference on Ozone Protection Technologies, Washington, DC., USA, pp. 845-854, 1996.
  6. Jetter, J. J. and Delafield, F. R., Alternatives for CFC12 refrigerant in automotive air conditioning, Proceedings of the International Conference on Ozone Protection Technologies, Baltimore, USA, pp. 366- 374, 1997.
  7. Houcek, J. and Thedford, M., A research into a new method of refrigeration charging and the effects of improper charging, Proceedings of the First Annual Symposium on Efficient Utilization of Energy in Residential and Commercial Buildings, Texas A&M Univ., TX, 1984,
  8. Frazad, M.and O'Neal, D. L., System performance characteristics of air conditioner over a range of charging conditions, International Journal of Refrigeration, Vol.14, No.6, pp.321-328, 1991. https://doi.org/10.1016/0140-7007(91)90027-E
  9. Choi, E. and Kim, J., The effects of the refrigerant charge on the performance of an air conditioner with capillary tube expansions, Korean Journal of Air- Conditioning and Refrigeration Engineering, Vol.14, No.5, pp.359-364, 2002.
  10. ANSI/ASHRAE Addenda a, b, c, d, e, f, g, and h to ANSI/ASHRAE Standard 34-2007, Designation and safety classification ofrefrigerants. ASHRAE June 2007.
  11. Jung, D.and Radermacher, R., Performance simulation of single-evaporator domestic refrigerators charged with pure and mixed refrigerant, International Journal of Refrigeration, Vol.13, No.4, pp.223 -232, 1991.
  12. Lemmon, E. W., Huber, M. L. and McLinden, M. O., NIST Reference Fluid Thermodynamics and Transport Properties, REFPROP version 8.0, 2007.