Abstract

This study is for quality standard establishment of urethane waterproofing membrane method which is mostly applied to waterproofing method for underground parking lot and rooftop. The experiments were carried out on color differences, membrane thickness, tensile property by curing period of liquid urethane before placing protective concrete, and resistance of crack movement according to different substrate surface and reinforcement of non-woven fabric. As a result of experiments, it was found that color differences is increase, membrane thickness is thick, tensile property is low as concrete placing period is shorter. In the fatigue property, membrane thickness of 3 mm was not broken, but 1~2 mm was broken and in the case of the membrane reinforced with non-woven fabric was more stable comparatively non-reinforcement one.

비노출형 도막방수재 도포 후 누름콘크리트 타설 시기에 따른 도막방수재의 물리적 특성과 바탕면 조건, 도막두께 및 보강포 사용유무에 따른 내피로성을 검토하였는데, 누름콘크리트 타설 시기가 짧을수록 변색이 심하였고, 도막두께가 두꺼운 반면 인장성능이 낮았다. 내피로 성능은 3 mm의 도막두께에서는 파단되지 않았으나 1, 2 mm는 모두 파단 되었고 부직포로 보강한 경우의 내피로성능이 상대적으로 우수한 것으로 나타났다.

Keywords

References

  1. An, S. R., Kwak, K. S., Choi, S. M., Oh, S. K., "Understanding of Waterproofing Construction Method and Construction Technology", Journal of the Korea Institute of Building Construction, Vol. 10, No. 4, 2010, pp.15-16 (in Korean).
  2. Cho, K. S., Park, W. Y., "The Rooftop Waterproof of Public Facilites and the Study of Improvement Way -Urethane Rubber Film Waterproof", Journal of the Korea Institute of Building Construction, Vol. 12, No. 6, 2012, p.86 (in Korean).
  3. KCL, "Test Evaluation of Liquid Waterproofing Material for Establishment of Quality Specification", 2010 (in Korean).
  4. Kim, D. K., "A Proposal of Water Leak Type and Countermeasure of Building Roof", Construction Technology Ssangyong, 2008 Autumn, p.54 (in Korean).
  5. Shin, H. J., "A Study on the Defect Causes Type for Poly-Urethane Waterproofing in Roof", Korean Journal of Construction Engineering and Management, Vol. 6, No. 3, 2005.6, pp.128-134 (in Korean).

Cited by

  1. A Study on the Joint Property by the Surface Treatment Method on the Jointing Method of PET Film using the High Hardness Liquid vol.18, pp.3, 2014, https://doi.org/10.11112/jksmi.2014.18.3.153
  2. 건설현장 우레탄 방수작업자의 휘발성 유기화합물 및 톨루엔 디이소시아네이트 노출평가 vol.30, pp.2, 2013, https://doi.org/10.15269/jksoeh.2020.30.2.134
  3. 수용성 고무 아스팔트계 도막방수재의 실외 적용을 위한 기본 물성 연구 vol.8, pp.4, 2013, https://doi.org/10.14190/jrcr.2020.8.4.553