석면 해체.제거 작업에서 사용되는 장비의 성능 기준에 관한 고찰

A Review on the Performance Criteria of Equipment Required for Asbestos Removal

  • 이나루 (한국산업안전보건공단 산업안전보건연구원)
  • Lee, Naroo (Occupational Safety and Health Research Institute, Korea Occupational Safety and Health Agency)
  • 발행 : 2013.09.30

초록

Objectives: Asbestos fibers are accumulated in negative pressure unit (NPU) or vacuum cleaner in asbestos removal. Failure of operation or poor use performance of the NPU or vacuum cleaner causes asbestos fibers to spread in the air. Asbestos contractors should have an NPU fitted with a HEPA , vacuum cleaner, decontamination area, respirators, wetting equipment, and differential pressure manometer to register with the Ministry of Employment and Labor. There should be performance criteria of equipment used in asbestos removal. But there are none such criteria used in asbestos removal. This study was performed to investigate international or national performance criteria of equipment used in asbestos removal. Methods: Regulations, approved code of practice, guidance and national standards of the UK, USA and Korea were reviewed. A survey was done to investigate the requirements for equipment used in asbestos removal in Korea. Results: Air flow of NPUs used in Korea usually covers from$500m^3/h$ to over $3000m^3/h$. Some requirements for NPUs used in Korea were missing compared to the requirements of British standards for NPUs. All NPUs have different missing requirements. The UK also has separate British standard for leak tests for NPUs. Highly hazardous class vacuum cleaners should be used in asbestos removal in the UK. It has national standards on the operation of vacuum cleaners used in asbestos removal. There is only a certification system for less than 2.5kw rated voltage vacuum cleaners for home use in Korea. Powered (-assisted) respirators with mask are recommended in asbestos removal. Type 5 coveralls should be used in asbestos removal in the UK. There are international standards for requirements and leak tests of type 5 coveralls. A manometer for measuring differential pressure is needed in asbestos removal. The manometer's measuring range should cover less than ${\pm}125$ Pa and the gradation of manometer should be less than 2.5 Pa. The definition of decontamination area should be corrected. Installation of airlock and minimum area should be considered in decontamination area. Conclusions: Equipment should be used in asbestos removal proper performance and no leaks. There should be a certification system for equipment used in asbestos removal. This study can help to a certification system for equipment used in asbestos removal in Korea.

키워드

참고문헌

  1. American National Standard Institute. Air filter units (ANSI/UL 586). 1959.
  2. American National Standard Institute. Code on nuclear air and gas treatment (AG-1-2012). 2012.
  3. American National Standard Institute(ANSI)/American Industrial Hygiene Association(AIHA). Portable ventilation systems(ANS/AIHA Z9.9-2010). 2010.
  4. Asbestos Removal Contractor's Association(ARCA). Recommended guidelines for personal decontamination procedures when working with asbestos. 2006.
  5. British Standards Institution. BS 8520-1: 2009 Equipment used in the controlled removal of asbestos-containing materials- Part 1 : Controlled wetting of asbestoscontaining materials - Specification 2009.
  6. British Standards Institution. BS 8520-2: 2009 Equipment used in the controlled removal of asbestos-containing materials- Part 2 : Negative pressure units - Specification 2009.
  7. British Standards Institution. BS 8520-3: 2009 Equipment used in the controlled removal of asbestoscontaining materials- Part 3 : Operation, Cleaning and maintenance of Class H vacuum cleaners- Code of practice 2009.
  8. British Standards Institution. BS EN 14325: 2004 Protective clothing against chemicals : Test methods and classification of chemicals protective clothing materials, seams, joins and assemblages 2009.
  9. British Standards Institution. BS EN 1822-1: 2009 High efficiency air filters (EPA, HEPA and ULPA). Classification, performance testing marking 2009.
  10. British Standards Institution. BS EN 1822-2: 2009 High efficiency air filters (EPA, HEPA and ULPA). Aerosol production, measuring equipment, particle counting statistics 2009.
  11. British Standards Institution. BS EN 1822-3: 2009 High efficiency air filters (EPA, HEPA and ULPA). Testing flat sheet filter media 2009.
  12. British Standards Institution. BS EN 1822-4: 2009 High efficiency air filters (EPA, HEPA and ULPA). Determining leakage of filter elements (scan method) 2009.
  13. British Standards Institution. BS EN 1822-5: 2009 High efficiency air filters (EPA, HEPA and ULPA). Determining the efficiency of filter elements (scan method) 2009.
  14. British Standards Institution. BS EN 60335-2.69: 2009 Household and similar electrical. appliance. Safety. Particular requirements for wet and dry vacuum cleaners including power brush for commercial use 2009.
  15. British Standards Institution. BS EN ISO 13982-1: 2004 Protective clothing for use against solid particulates. Performance requirements for chemical protective clothing providing protection to the full body against airborne solid particulate (type 5 clothing). 2004.
  16. British Standards Institution. BS EN ISO 13982-2: 2004 Protective clothing for use against solid particulates. Test method of determination of inward leakage of aerosols of fine particles into suits. 2004.
  17. Choi S, Suk MH, Paik NW. Asbestos-containing materials and airborne asbestos levels in industrial buildings in Korea. J UOEH. 2010;32(1);31-43 https://doi.org/10.7888/juoeh.32.31
  18. Great Britain. The control of asbestos regulations 2006. London: The Stationery Office.
  19. Health & Safety Executive. Respiratory protective equipment at work (HSG53). 2005
  20. Health & Safety Executive. The management of asbestos in non-domestic premises. Approved Code of Practice and guidance. 2006.
  21. Health & Safety Executive. Work with materials containing asbestos. Control of Asbestos Regulations 2006 Approved Code of Practice and guidance. 2006.
  22. Health & Safety Laboratory(HSL). Investigation into the effectiveness of modular hygiene unit. 2001.
  23. Hoffman K. Asbestos abatement training for contractors and supervisors. TSTC Publishing. 2009. p.77. p127. p133
  24. Institute of Environmental Sciences and Technology. HEPA and ULPA filter leak tests (IEST-RP-CCCC034.2). 2005.
  25. Institute of Environmental Sciences and Technology. HEPA and ULPA Filters (IEST RP-CC001.5). 2010.
  26. Institute of Environmental Sciences and Technology. HEPA and ULPA filters (IEST-RP-CC001.4). HEPA and ULPA filters. 2005.
  27. Institute of Environmental Sciences and Technology. Testing cleanrooms (IEST-RP-CC006.2:1993). 1993.
  28. Institute of Environmental Sciences and Technology. Testing ULPA filters (IEST-RP-CC001.3: 1993). 1993.
  29. Institute of Environmental Sciences and Technology. Testing ULPA filters (IEST-RP-CC007.1: 1992). 1992.
  30. Kim TH, Ha HC, Kim KY, KIm JC, Jeong YJ. Research on management of asbestos removal for prevention of dispersion asbestos fiber. Ministry of Environment. 2010. p.124 In Korean
  31. Kim JY, Lee SK, Lee JH, Lim MH, Kang SW, Phee YG. A study on the factors affecting asbestos abatement in building demolition sites. J of KIHA 2009;19(1);8-15 p110 In Korean
  32. Korea Air Cleaning Association. Test method on HEPA filter. 2009. In Korean
  33. Korea Occupational Safety and Health Agency(KOSHA). Guideline on asbestos removal. KOSHA Guide H-70-2012. 2012. In Korean
  34. Korean Agency for Technology and Standards. KS A 4812 : 2001 HEPA filters for radioactive aerosols 2001. In Korean
  35. Korean Agency for Technology and Standards. KS B 6740 : 1995 Cleanroom- air filters-Test methods 1995. In Korean
  36. Korean Agency for Technology and Standards. KS K ISO 13982-1: 2007 Protective clothing for use against solid particulates-Part 1: Performance requirements for chemical protective clothing providing protection to the full body against airborne solid particulates (type 5 clothing) 2007. In Korean
  37. Korean Agency for Technology and Standards. KS K ISO 13982-2: 2007 Protective clothing for use against solid particulates-Part 2: Test method of determination of inward leakage of aerosols of fine particles into suits 2007. In Korean
  38. Korean Agency for Technology and Standards.. KS C IEC 60335-2-69: 2007 Household and similar electrical appliances-Safety-Part 2-69 : Particular requirements for wet and dry vacuum cleaners, including power brush, for industrial and commercial use 2007. In Korean
  39. Roh YM, Suk MH, Na CP, Kim KY, Cho TJ, Sim SH, Ha HC. A research of infrastructure standard for asbestos abatement in Korea. Incheon; Occupational Safety and Health Research Institute: 2008. p335 In Korean
  40. The American Society of Mechanical Engineers. ASME N 510-2007. Testing of nuclear air treatment systems. 2007.
  41. USA. Department of defense. MIL-STD-282: Filter Unit, Protective Clothing, Gas-mask Components and Related Products : Performance test methods. 1952.
  42. USA. Occupational Safety and Health Administration. Safety and health regulations for contruction Toxic and Hazardous Substances(1926.1101). [cited 2011 Nov 1] Available from URL: http://www.osha.- gov/pls/oshaweb/