DOI QR코드

DOI QR Code

경량 무기발포패널을 적용한 커튼월 시스템의 내화성능분석

Analysis of Fire Resistance Performance of Curtain-Wall Systems Applying Light-Weight Inorganic Panels

  • 발행 : 2013.07.25

초록

Lightweight curtain-wall systems applying aluminum and glass are usually in use, thereby increasing of high-rise and large buildings. Commonly inorganic insulations are better fire-performance than the organic insulation, but in a lightweight respect, it is disadvantageous than insulation mortars. For this reason, there is a growing interest in materials for a high-fire resistance and a high-lightweight. In this study, fire tests on the basis of EN13830 were performed on the curtain-wall applying newly developed light-weight inorganic panels and the typical curtain-wall with mineral-wool panels. From the test, fire resistance integrity, thermal insulation, and radiation properties were compared for both system. From the test results, the curtain-wall applying the newly developed light-weight inorganic panels showed better fire-performance than the typical curtain-wall for the fire resistance integrity and insulation.

키워드

참고문헌

  1. 조봉호, 윤경조, 임현창, 김진호, 신성호, "스틸 커튼월 시장동향 및 초고층 커튼월 적용성 평가", 강구조학회지, Vol 22, No. 2, p.p. 27-33, 2010
  2. 이재승, 조봉호, 임현창, "커튼월 내화성능에 관한 고찰", 강구조학회지, Vol 22, No. 5, p.p. 14-18, 2010
  3. 한국세라믹기술원, 고층빌딩 커튼월용 내화성 적용기술 개발, 2010
  4. 이재승, 임현창, 김흥열, 김형준, 조봉호, "커튼월의 내화 성능 평가에 관한 실험적 연구", 대한건축학회논문집 구조계, Vol 2 7, No. 7, p.p. 141-148, 2011
  5. 이재승, 임현창, 조봉호, 김흥렬, "스틸-알루미늄 복합 프레임을 갖는 커튼월의 내화성능에 관한 실험적 연구", 한국화재소방학회 논문지, Vol 25, No. 6, 2011
  6. ASTM E119 "Standard Test Methods for Fire Tests of Bui lding Construction and Materials"
  7. ASTM E136 "Standard Test Method for Behavior of Mater ials in a Vertical Tube Furnace at $750^{\circ}C$"
  8. ASTM E2307 "Standard Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems Using Interm ediate Scale, Multi story Test Apparatus"
  9. ASTM E176 "Standard Terminology of Fire Standards"
  10. AAMA MCWM-1-89 "Metal Curtain Wall Manual"
  11. ISO 3009 "Fire resistance tests-Elements of building const ruction. Glazed elements"
  12. ISO 834-8 "Fire resistance tests-Elements of building con struction. Part 8: Specific requirements for non-loadbearin g vertical separating elements"
  13. ISO 10295-1 "Fire tests for building elements and compon ents - Fire testing of service installations. Part 1: Penetra tion seals"
  14. ISO 10295-2 "Fire tests for building elements and compon ents - Fire testing of service installations. Part 2: Linear joint (gap) seals"
  15. ISO 12136 "Reaction to fire tests - Measurement of mater ial properties using a fire propagation apparatus"
  16. EN 1364-3 "Fire resistance tests for non-loadbearing elem ents. Part 3: Curtain walls - full configuration"
  17. EN 1364-4 "Fire resistance tests for non-loadbearing elem ents. Part 3: Curtain walls - Part configration"
  18. EN 1366-4 "Fire resistance tests for service installations. Part 4:Linear joint seals"
  19. EN 13830 "Curtain walling. Product standard"
  20. EN 13501-1 "Fire classification of construction products an d building elements. Part 1: Classification using data from reaction to fire tests"
  21. EN 13501-2 "Fire classification of construction products an d building elements. Part 2: Classification using data from fire resistance tests"
  22. EN 1363-1 "Fire resistance tests. Part 1: General requirements"
  23. EN 1363-2 "Fire resistance tests. Part 2: Alternative and additional procedures"