Abstract

This paper analyzes economics and investigates the possibility of elastic seismic design of wind-designed high-rise steel diagrid frames with torsional irregularity in Korea. To this end, high-rise steel diagrid frames with twist angles of $0^{\circ}$ (to represent regular building), $1^{\circ}$, and $2^{\circ}$ were first designed to resist wind loads. Then, seismic performance evaluation for the buildings was conducted using linear dynamic analysis. Analysis results show that total steel weights of the wind-designed high-rise steel diagrid frames with twist angle of $1^{\circ}$ and $2^{\circ}$ are about 1.14 and 1.22 times larger, respectively, than the weight of regular frame with twist angle of $0^{\circ}$. Demand-to-capacity ratio and seismic performance level present that high-rise steel diagrid frames can resist service level earthquake elastically whether high-rise building has torsional irregularity or not. For maximum considered earthquake, high-rise steel diagrid frames with torsional irregularity may be designed based on the limited ductility seismic design methodology.

Keywords

References

  1. Council on Tall Buildings and Urban Habitat (CTBUH), Recommendations for the Seismic Design of Highrise Buildings, CTBUH, 2008
  2. Los Angeles Tall Buildings Structural Design Council (LATBSDC), An alternative procedure for seismic analysis and design of tall buildings located in the Los Angeles region: consensus document, LATBSDC, 2011
  3. Pacific Earthquake Engineering Research Center (PEER), Tall Buildings Initiative Guidelines for Performance-Based Seismic Design of Tall Buildings, Report No. 2010/05, PEER, 2010
  4. American Society of Civil Engineers (ASCE), Seismic Rehabilitation of Existing Buildings (ASCE Standard ASCE/SEI 41-06), ASCE, 2010
  5. Holmes, J. D., Wind Loading of Structures, 2nd Ed., Taylor and Francis Group, 2007
  6. 대한건축학회, 건축구조기준 및 해설, 대한건축학회, 2009
  7. American Society of Civil Engineers (ASCE), Minimum Design Loads for Buildings and Other Structures (ASCE/SEI 7-10), ASCE, 2010
  8. Lee, C.-H., Kim, S., Elastic Seismic Design of Steel Highrise Buildings in Regions of Strong Wind and Moderate Seismicity, International Journal of Steel Structures, 7(4), 253-262, 2007 https://doi.org/10.12989/scs.2007.7.3.253
  9. 이동근, 건축물의 내진설계를 위한 구조동역학(제2부: 등가정적해석법의 배경), 건축구조기술사회지, 13(2), pp.37-47, 2006
  10. Structural Engineers Association of California(SEAOC), Recommended Lateral Force Requirements and Commentary, SEAOC, 1959
  11. 김선웅, 초고층 철골대각가새골조의 내진성능평가, 한국전산구조공학회 논문집, 24(3), pp.307-317, 2011
  12. 김재관, 김익현, 중진지역에서의 한정연성도 내진설계, 한국지진공학회 추계학술대회 논문집, 2, pp.75-84, 1998
  13. Moon, K.S., Diagrids for Structural Design and Construction of Complex-Shaped Tall Buildings, Proceedings of Structural Engineers World Congress 2011, Italy, 2011
  14. Moon, K.S., Connor, J.J., Fernandez, J.E., Diagrid Structural Systems for Tall Buildings: Characteristics and Methodology for Preliminary Design, the Strcutural Design of Tall and Special Buildings, 16, pp.205-230, 2007 https://doi.org/10.1002/tal.311
  15. National Building Code of Canada (NBCC), 2005
  16. 김선웅, 이경구, 노풍도에 따라 내풍설계된 초고층 대각가새골조의 내진성능평가, 26(11), 대한건축학회논문집, pp.47-56, 2010
  17. 김선웅, 초고층 철골중심가새골조의 내진성능평가, 27(7), 대한건축학회논문집, pp.65-75, 2011
  18. MIDAS Genw, General Structure Design System for Windows, MIDASIT, 2010
  19. Satake, N., Suda, K., Arakawa, T., Sadaki, K, Tamura, Y., Damping evaluation using full scale data of buildings in Japan, Journal of Structural Engineering, ASCE, 129(4), 470-477, 2003 https://doi.org/10.1061/(ASCE)0733-9445(2003)129:4(470)
  20. Tamura, Y, Amplitude dependency of damping in buildings and estimation techniques, Proceedings of 12th AWES Wind Engineering Workshop, Australasian Wind Engineering Society, Queentown, New Zealand, 2006