DOI QR코드

DOI QR Code

Measurement of the Biological Active Point using the Bio-electrical impedance analysis based on the Adaptive Frequency Tracking Filter

적응주파수추적필터기반의 생체임피던스분석을 통한 생물학적활성점측정에 관한 연구

  • Received : 2013.10.10
  • Accepted : 2013.12.13
  • Published : 2013.12.31

Abstract

The biological active points (BAP) are known as low resistance spots or good electro-permeable points. In this paper, a new method for BAP detection using the bio-impedance measurement system based on the adaptive frequency tracking filter (AFTF) and the transition event detector is presented. Also, the microcontroller process continuous time demodulation of the modulated signal by multi frequency components using the AFTF. The transition event detector based on the phase space method is applied about each frequency using the BAP equivalent model which is proposed.

낮은 저항이나 좋은 전기투과도 지점으로 알려진 생물학적 활성점(biological active points, BAP)인 BAP검출을 위한 새로운 방법으로 적응주파수추적필터와 과도이벤트검출을 기반으로 하는 생체임피던스측정시스템을 사용하는 방식에 대해 제안하였다. 이 생체임피던스장치에 다중주파수 전류주입과 전압측정 모두 표면전극을 사용하였다. 또한 마이크로컨트롤러를 통하여 적응주파수추적필터를 사용한 다중주파수요소에 의해 변조된 신호의 연속적인 복조를 처리하였다. 또한 위상공간방식의 과도이벤트검출방식이 제안된 BAP등가모델에 각주파수에 대해 적용되었다.

Keywords

References

  1. Jonas WB and Levin JS: "Essentials of Complementary and Alternative Medicine", Williams & Wilkins.
  2. E. F. Prokhorov: "In vivo electrical characteristics of human skin, including at biological active points" Med. Biol. Eng. Compute., 38, 507-511, 2000 https://doi.org/10.1007/BF02345745
  3. VOLL,R.: Messbare Acupunctur-Diagnostic und Therapiefurden Praktier", Elfahrung heilkunde, 4, 1955
  4. NAKATANI, Y.: "Skin electric resistance and ryodoraku", J. Autonomic Nerve, 6, p. 52, 1956
  5. KRAMER, F.: "'Elnftmrung in die Electroacupunturnach Voll', Med.-Lit. Verlag, Uelzen, 1972
  6. Lusseveld EM, Peters E T and Deurenberg P: "Multifrequency bioelectrical impedance as a measure of differences in body water distribution" Ann. Nutr. Metab. 37,pp44-51, 1993 https://doi.org/10.1159/000177748
  7. Srinivasan, N., M. T. Wong, and S. M. Krishnan: "A new phase space analysis algorithm for cardiac arrhythmia detection" EMBC 82-85, 2003
  8. Mark, G., Frei et al.:"Least squares acceleration filtering for the estimation of signal derivatives and sharpness at extrema". IEEE Trans. Biomed. Eng. 46(8):971-977, 1999
  9. Jae-Seung Choi, "Speech Synthesis Algorithm Applied to Methods of Multi-Cepstrum Extraction and Root Mean Square Amplitude". Journal of Korean Institute of Information Technology, Vol.11 No.6 2013.6, page(s): 157-162
  10. Dae-chul Cho, Sung-Hyun Kwon, "Operation of Biofilters with Different Packing Material - development of media and biological parameters for optimal odor treatment process in a biofilter". Journal of the Korea Academia-industrial cooperation Society, v.4, no.3, September 2003, pp.236-241