DOI QR코드

DOI QR Code

A Study on the Inner tank Seismic Analysis Model for Calculation of Seismic Forces of LNG Storage Tank

LNG저장탱크 지진력 산정을 위한 내부탱크 지진해석 모델에 관한 연구

  • 김미승 (한국가스공사 연구개발원) ;
  • 이강원 (한국가스공사 연구개발원) ;
  • 김준휘 (한국가스공사 연구개발원) ;
  • 윤인수 (한국가스공사 연구개발원)
  • Received : 2013.09.09
  • Accepted : 2013.10.11
  • Published : 2013.10.31

Abstract

LNG(Liquefied Natural Gas) has been considered as the green energy. Thus, the demand of natural gas is keep increasing around the world, and various studies are actively under progress about the LNG storage tank. To calculate the seismic forces of actual LNG storage tank, FEM model has to include inner tank, outer tank, pile and soil to implement the interaction between structure and ground. So, this paper is represent the study about inner tank model of three cases using Malhotra method in EN 1998-4(European Standard). The results of calculation were compared, and the most suitable to inner tank model was suggested.

환경 친화적 에너지로 고려되는 LNG(Liquefied Natural Gas)는 그 수요량이 계속 증가하고 있으며, 이에 따라 LNG를 저장하는 LNG저장탱크에 관한 다양한 연구도 활발히 진행되고 있다. 실제 LNG저장탱크의 지진력 산정시 구조물과 지반의 상호작용을 구현하기 위해서는 내부탱크, 외부탱크, 파일 그리고 지반을 함께 모델링하여 유한요소해석을 수행하여야 한다. 따라서 본 연구는 EN 1998-4(European Standard)에 채택되어 있는 Malhotra 방법을 적용하여 세 가지의 내부탱크 모델에 대한 연구를 수행하였으며, 이를 수계산 결과와 비교 분석함으로써 EN코드에 가장 적합한 내부탱크 모델을 구축하였다.

Keywords

References

  1. Eurocode 8: Design of structures for earthquake resistance- Part 4: Silos, tanks and pipelines, British Standards, (2006)
  2. Praveen K. Malhotra, Thomas Wenk, Martin Wieland, "Simple Procedure for Seismic Analysis of Liquid-Storage Tanks", Structural Engineering International, (2010)
  3. 유체-구조물-지반 상호작용 시설물의 내진설계 (제7회 기술강습회), 한국지진공학회, 131-155