References
- Doi K: Diagnostic imaging over the last 50 years: research and development in medical imaging science and tecnology. Phys Med Biol, 51(13), R5-R27, 2006 https://doi.org/10.1088/0031-9155/51/13/R02
- Sang-Tae Kim, Beom-Hui Han : Evaluation of the patient dose in case of standard radiographic examinations using CR and DR. Journal of Radiological Science and Technology. 33(3), 173-178, 2010
- Ho-Kyung Kim : Sensor technology for digital radiography : Journal of the Korean society of precision engineering, 22(8), 7-16, 2005
- Cowen AR, Workman A and Price JS: Physical aspects of photostimulable phosphor computed radiography. Br. J. Radial, 66(784), 332-345, 1993 https://doi.org/10.1259/0007-1285-66-784-332
- Jung-Min Kim, Jung-Whan Min, Hoi-Woun Jeong et al :The Noise Evaluation for Ragius 150 CR System, Journal of Radiological Science and Technology, 29(4), 237-240, 2006
- Fuller MJ: Breathing Exposure Techniques in Radiography, Lateral chest X-ray Digital Double-Dipping, Soft Tissue Signs-Thoracic Spine. wikiRadiography
- Kang SS, Ko SG and Ko IH: TEXTBOOK of Radiographic Positioning and Clinical Diagnosis. Chung-Ku publishing Co, 225-250, 2008
- Jung-Whan Min, Jung-Min Kim, Hoi-Woun Jeong : Mixed Noise reduction Filters for CR Images. Journal of Radiological Science and Technology, 30(1), 1-6, 2007
- Jung-Whan Min, Jung-Min Kim, Hoi-Woun Jeong et al : Research about filter association and clinical effect noise reduction of digital medical imaging system. Journal of Radiological Science and Technology, 30(4), 329-334, 2007
- Hoi-Woun Jeong, Jung-Whan Min, Jung-Min Kim et al : Performance characteristic of a Cs I (TI) Flat panel detector radiography system. Journal of Radiological Science and Technology, 35(2), 109-117, 2012
- Hye-Suk Park, Yu-Na Oh, Hee-Jeong Jo et al: Comparison study of image quality of direct and indirect conversion digital mammography system. Korean Journal of Medical Physics, 21(3), 239-245, 2010
- Ho-Kyung Kim, Min-Kook Cho, Thorsten Graeve: Investigation of radiation effects on the signal and noise characteristics in digital radiography. Korean Society of Medical and Biological Engineering, 28(6), 756-767, 2007
- Samei E and Flynn MJ: An experimental comparison of detector performance for direct and indirect digital radiography systems. Med. Phys, 30(4), 608-622, 2003 https://doi.org/10.1118/1.1561285
- Samei E and Flynn MJ: Physical measure of image quality in photostimulable phosphor radiographic system. Proc SPIE, 3032, 328-338, 1997
- Jung-Whan Min, Soon-Yong Son, Ki-Won Kim et al: Evaluation of quantitative on T-spine exhalation technique and T-spine breathing technique of natural breathing. Journal of the Korea Academia-Industrial Cooperation Society, 14(9), 4429-4436, 2013 https://doi.org/10.5762/KAIS.2013.14.9.4429
- Guan Huaiqun, Richard Gordon and Yunping Zhu: Combining various projection access schemes with the algebraic reconstruction technique for low-contrast detection in computed tomography. Phys Med Biol, Aug;43(8):2413-21, 1998 https://doi.org/10.1088/0031-9155/43/8/032
- Andy C: Modified Lateral Thoracic Spine Technique, Imaging Vertebral Body Wedge Fractures, Aluminium Filter Techniques in Radiography. wikiRadiography
- Jin-Woo Choi, Won-Jin Yi: Physical principles of digital radiographic imaging system. Korean academy of oral and maxillofacial radiology, 40(4), 155-158, 2010
- Rowlands JA, Ji WG, Zhao W and Lee DLY: Direct conversion flat-panel x-ray imaging: Reduction of noise by presampling filtration. Proc SPIE, 3977, 446-455, 2000
- Yun SM, Lim CH and Han JC, et al: Signal and noise analysis of indirect-conversion digital radiography detectors using linear-systems transfer theory. Korean J Med Phys, 21(3), 261-273, 2010