This study investigated the effects of the alkaline detergent and acid rinse used for cleaning milking machines on the eight commercially available teatcup liner materials. The sample liners prepared for use in the clean-in-place process were analyzed by ultraviolet spectrophotometer, ion chromatography and liquid chromatography. Among the eight liner materials, the ultraviolet spectra of 3 sample liners were shown to have a similar peak shape after cleaning, but the ultraviolet spectra peak shape of 5 sample liners was noticeably changed. No products were detected by ion chromatography in any of the liner materials used in this study. When the liner materials were only treated with alkaline detergent, some additional peaks were observed using liquid chromatography which indicate the creation of molecular substance and elution from liner materials, however, these peaks disappeared when the liner materials were cleaned with the acid rinse. Therefore, we propose that an acid rinse should be applied, after cleaning the milking machine with the alkaline detergent.

Keywords

References

  1. 이정치, 박형련, 김명선, 이정길, 이채용. 2005. 유두컵 라이너의 물리화학적 특성 조사. 한국임상수의학회지 22:100-107.
  2. Edmondson P. 2003. Cleaning the milking machine (http://www. milkproduction.com/Library/Articles/Cleaning_the_ Milking_Machine.htm).
  3. Hogan JS, Harmon RJ, Langlois BE, Hemken RW, Crist WL. 1984. Efficacy of an iodine backflush for preventing new intramammary infections. J Dairy Sci 67: 1850-1859. https://doi.org/10.3168/jds.S0022-0302(84)81513-1
  4. Hovinen M, Aisla AM, Pyorala S. 2005. Visual detection of technical success and effectiveness of teat cleaning in two automatic milking systems. J Dairy Sci 88: 3354-3362. https://doi.org/10.3168/jds.S0022-0302(05)73019-8
  5. Levesque P. 1998. Teatcup liners. Product Lait Quebe 18: 34-36.
  6. Magee C, Sagi R, Scott NR, Gates RS. 1984. Bacterial transport within and among various teatcup and cluster assemblies during milking. J Dairy Sci 67: 2034-2040. https://doi.org/10.3168/jds.S0022-0302(84)81540-4
  7. Reinemann DJ, Wolter GMVH, Rasmussen MD. 2000. Review of practices for cleaning and sanitation of milking machine. (http://www.uwex.edu/uwmril/pdf/MilkMachine/Cleaning/ 00_Nagano_CIP.pdf).
  8. Schreiner DA, Ruegg PL. 2003. Relationship between udder and leg hygiene scores and subclinical mastitis. J Dairy Sci 86: 3460-3465. https://doi.org/10.3168/jds.S0022-0302(03)73950-2
  9. Smith TW, Eberhart RJ, Spencer SB, Kesler EM, Hargrove GL, Wilson RW, Heald CW. 1985. Effect of automatic backflushing on number of new intramammary infections, bacteria on teatcup liners, and milk iodine. J Dairy Sci 68: 424-432. https://doi.org/10.3168/jds.S0022-0302(85)80840-7

Cited by

  1. 착유기 세척제가 신개발 젖소 유두컵 라이너용 고무조성물 재질에 미치는 화학적 영향 vol.41, pp.2, 2013, https://doi.org/10.7853/kjvs.2018.41.2.125