DOI QR코드

DOI QR Code

Development of a methodology for damping of tall buildings motion using TLCD devices

  • Diana, Giorgio (Department of Mechanical Engineering, Politecnico di Milano) ;
  • Resta, Ferruccio (Department of Mechanical Engineering, Politecnico di Milano) ;
  • Sabato, Diego (Department of Mechanical Engineering, Politecnico di Milano) ;
  • Tomasini, Gisella (Department of Mechanical Engineering, Politecnico di Milano)
  • Received : 2011.08.23
  • Accepted : 2013.07.30
  • Published : 2013.12.25

Abstract

One of the most common solutions adopted to reduce vibrations of skyscrapers due to wind or earthquake action is to add external damping devices to these structures, such as a TMD (Tuned Mass Damper) or TLCD (Tuned Liquid Column Damper). It is well known that a TLCD device introduces on the structure a nonlinear damping force whose effect decreases when the amplitude of its motion increases. The main objective of this paper is to describe a Hardware-in-the-Loop test able to validate the effectiveness of the TLCD by simulating the real behavior of a tower subjected to the combined action of wind and a TLCD, considering also the nonlinear effects associated with the damping device behavior. Within this test procedure a scaled TLCD physical model represents the hardware component while the building dynamics are reproduced using a numerical model based on a modal approach. Thanks to the Politecnico di Milano wind tunnel, wind forces acting on the building were calculated from the pressure distributions measured on a scale model. In addition, in the first part of the paper, a new method for evaluating the dissipating characteristics of a TLCD based on an energy approach is presented. This new methodology allows direct linking of the TLCD to be directly linked to the increased damping acting on the structure, facilitating the preliminary design of these devices.

Keywords

References

  1. Balendra, T., Wang C.M. and Cheong H.F. (1995), "Effectiveness of tuned liquid column dampers for vibration control of towers", Eng. Struct., 17(9), 668-675. https://doi.org/10.1016/0141-0296(95)00036-7
  2. Blevins, R.D. (1984), Applied fluids dynamics handbook, Von Nostrand Reinhold, New York.
  3. Chaiviriyawong, P., Webster, W.C., Pinkaew, T. and Lukkunaprasit, P. (2007), "Simulation of characteristics of tuned liquid column damper using potential flow method", Eng. Struct., 29(1), 132-144. https://doi.org/10.1016/j.engstruct.2006.04.021
  4. Cheli, F., Corradi, R., Rocchi, D., Tomasini, G. and Maestrini, E. (2010) "Wind tunnel tests on train scale models to investigate the effect of infrastructure scenario", J. Wind Eng. Ind. Aerod., 98(6-7), 353-362. https://doi.org/10.1016/j.jweia.2010.01.001
  5. Cheli, F., Corradi, R., Sabbioni, E. and Tomasini, G. (2011a), "Wind tunnel tests on heavy road vehicles: Cross wind induced loads - Part 1", J. Wind Eng. Ind. Aerod., 99(10), 1000-1010. https://doi.org/10.1016/j.jweia.2011.07.009
  6. Cheli F., Ripamonti F., Sabbioni E. and Tomasini G. (2011b), "Wind tunnel tests on heavy road vehicles: Cross wind induced loads - Part 2", J. Wind Eng. Ind. Aerod., 99(10), 1011-1024. https://doi.org/10.1016/j.jweia.2011.07.007
  7. Cheli, F., Corradi, R. and Tomasini, G. 2012), "Crosswind action on rail vehicles: A methodology for the estimation of the characteristic wind curves", J. Wind Eng. Ind. Aerod., 104-106, 248-255.
  8. Chen, Y.H. and Chou, CC. (2000), "Optimal damping ratios of TLCDs", Struct. Eng. Mech., 9(3), 227-240. https://doi.org/10.12989/sem.2000.9.3.227
  9. Chen, Y.H. and Ko, C.H. (2003), "Active tuned liquid column damper with propellers", Earthq. Eng. Struct. D., 32(10), 1627-1638. https://doi.org/10.1002/eqe.295
  10. Debbarma, R., Chakraborty, S. and Ghosh, S.K. (2010), "Optimum design of a tuned liquid column dampers under stochastic earthquake load considering uncertain system parameters", Int. J. Mech. Sci., 52(10), 1385-1393. https://doi.org/10.1016/j.ijmecsci.2010.07.004
  11. Diana, G., Cigada, A., Belloli, M. and Vanali, M. (2003), "Stockbridge-type damper effectiveness evaluation: Part I - Comparison between tests on span and on the shaker", IEEE T. Power Deliver., 18(4), 1462-1469. https://doi.org/10.1109/TPWRD.2003.817797
  12. Diana, G., Giappino, S., Resta, F., Tomasini, G. and Zasso, A. (2009), "Motion effects on the aerodynamic forces for an oscillating tower through wind tunnel tests", EACWE 5, Proceedings of the 5th European and African Conference on Wind Engineering, Florence, Italy, 19-23, July.
  13. Diana, G., Resta, F., Sabato, D. and Tomasini, G. (2012), "Experimental characterization and model of a modular square-section TLCD device", EACS2012, Proceedings of the 5th European Conference on Structural Control, Genoa, Italy, June.
  14. Gao, H., Kwok, K.S.C. and Samali, B. (1999), "Characteristics of multiple tuned liquid column dampers in suppressing structural vibration", Eng. Struct., 21(4), 316-331. https://doi.org/10.1016/S0141-0296(97)00183-1
  15. Giappino, S., Rosa, L., Tomasini, G. and Zasso, A. 2012), "Aeroelastic effects on a high-rise rectangular section building", Proceedings of the World Congress on Advances in Civil, Environmental, and Materials Research (ACEM 12), Seoul, Korea, 26-30, August.
  16. Heo, J.S., Lee, S.K., Park, E.C., Lee, S.H., Min, K.W., Kim, H., Jo, J. and Cho, B.H. (2009), "Performance test of a tuned mass damper for reducing bidirectional responses of building structures", Struct. Des. Tall Spec., 18(7), 789-205. https://doi.org/10.1002/tal.486
  17. Hitchcock, P.A., Kwok, K.C.S., Watkins, R.D. and Samali, B. (1997), "Characteristics of liquid column vibration absorbers (LCVA) - I, II", Eng. Struct., 19, 126 -144. https://doi.org/10.1016/S0141-0296(96)00042-9
  18. Lee, S.K., Min K.W. and Lee H.R. (2010), "Parameters identification of a new bidirectional tuned liquid column and sloshing damper", J. Sound Vib., 330(7), 1312-1327.
  19. Lee S.K., Park, E.C., Lee, S.H., Min, K.W., Park, J.H. and Chung, L. (2007), "Real-time hybrid shaking table testing method for performance evaluation of a TLD controlling seismic response of building structures", J. Sound Vib., 302(3), 596-612. https://doi.org/10.1016/j.jsv.2006.12.006
  20. Rosa, L., Tomasini, G. and Zasso, A. (2009), "Dynamic response and wind loads of a tall building based on wind tunnel tests", EACWE 5, Proceedings of the 5th European and African Conference on Wind Engineering, Florence, Italy, 19-23 July.
  21. Rosa, L., Tomasini G., Zasso, A. and Aly, A.M. (2012a), "Wind-induced dynamics and loads in a prismatic slender building A modal approach based on unsteady pressure measurements", J. Wind Eng. Ind. Aerod., 107-108, 118-130. https://doi.org/10.1016/j.jweia.2012.03.034
  22. Rosa, L., Tomasini, G., Zasso, A. and Aly, A.M. 2012b), "Evaluation of wind-induced dynamics of high-rise buildings by means of modal approach", Proceedings of the 2012 World Congress on Advances in Civil, Environmental, and Materials Research (ACEM 12), Seoul, Korea, 26-30, August.
  23. Rosa, L., Giappino, S., Tomasini, G. and Zasso, A. (2013), "An aerodynamic and aeroelastic experimental study on a sectional and three-dimensional rectangular prism with 2.6:1 aspect ratio", J. Wind Eng. Ind. Aerod., in press.
  24. Tomasini, G. and Cheli, F., 2013), "Admittance function to evaluate aerodynamic loads on vehicles: Experimental data and numerical model", J. Fluid. Struct., 38, 92-106. https://doi.org/10.1016/j.jfluidstructs.2012.12.009
  25. Sadek, F., Mohraz, B. and Lew, H.S. (1998), "Single and multiple-tuned liquid column damper for seismic applications", Earthq. Eng. Struct. D., 27, 439-463. https://doi.org/10.1002/(SICI)1096-9845(199805)27:5<439::AID-EQE730>3.0.CO;2-8
  26. Shum, K.M. (2008), "Closed form optimal solution of a tuned liquid column damper for suppressing harmonic vibration of structures", Eng. Struct., 31(1), 84-92.
  27. Sun, K. (1994), "Earthquake responses of buildings with liquid column dampers", Proceedings of the 5th U.S. National Conference on Earthquake Engineering, Chicago, U.S.A.
  28. Symans, M.D. and Constantinou, M.C. (1999), "Semi-active control systems for seismic protection of structures : a state-of-the-art review", Eng. Struct., 21(6), 469-487. https://doi.org/10.1016/S0141-0296(97)00225-3
  29. Won, A.Y.J., Piers, J.A. and Haroun, M.A. (1996), "Stochastic seismic performance evaluation of tuned liquid column dampers", Earthq. Eng. Struct. D., 25(11), 1259-1274. https://doi.org/10.1002/(SICI)1096-9845(199611)25:11<1259::AID-EQE612>3.0.CO;2-W
  30. Yalla, S.K. and Kareem, A. (2000), "Optimum absorber parameters for tuned liquid column dampers", J. Struct. Eng. - ASCE, 126(8), 906-915. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:8(906)
  31. Yalla, S.K., Kareem, A. and Kantor, J.C. (2001), "Semi-active tuned liquid column damper for vibration control of structures". Eng. Struct., 23, 1469-1479. https://doi.org/10.1016/S0141-0296(01)00047-5
  32. Xu, Y.L., Samali, B., and Kwok, K.C.S. (1992), "Control of along-wind response of structures by mass and liquid dampers", J. Eng. Mech. - ASCE, 118 (1), 20-39. https://doi.org/10.1061/(ASCE)0733-9399(1992)118:1(20)
  33. Xue, S.D., Ko, J.M. and Xu, Y.L. (2000), "Tuned liquid column damper for suppressing pitching motion of structure", Eng. Struct., 23, 1538-1551.

Cited by

  1. Performance of a Single Liquid Column Damper for the Control of Dynamic Responses of a Tension Leg Platform vol.628, 2015, https://doi.org/10.1088/1742-6596/628/1/012058
  2. Dynamic response mitigation of floating wind turbine platforms using tuned liquid column dampers vol.373, pp.2035, 2015, https://doi.org/10.1098/rsta.2014.0079
  3. An aerodynamic and aeroelastic experimental study on a sectional and three-dimensional rectangular tall building vol.25, pp.3, 2016, https://doi.org/10.1002/tal.1232
  4. Tuned Liquid Column Damper based Reduction of Dynamic Responses of Scaled Offshore Platforms in Different Ocean Wave Basins vol.842, 2017, https://doi.org/10.1088/1742-6596/842/1/012043
  5. Optimum LCVA for suppressing harmonic vibration of damped structures vol.20, pp.4, 2013, https://doi.org/10.12989/sss.2017.20.4.461
  6. Parametric optimization of an inerter-based vibration absorber for wind-induced vibration mitigation of a tall building vol.31, pp.3, 2020, https://doi.org/10.12989/was.2020.31.3.241
  7. Vibration Control of Structures by an Upgraded Tuned Liquid Column Damper vol.147, pp.9, 2021, https://doi.org/10.1061/(asce)em.1943-7889.0001965