Analysis of Greenhouse Gas Reduction Potentials in a University using Bottom-up Model

상향식 모형을 이용한 대학의 온실가스 감축 잠재량 평가

  • Yoo, Jung-Hwa (Department of Environmental & Energy, Sejong University) ;
  • Park, Nyun-Bae (Cooperate Course for Climate Change, Sejong University) ;
  • Jo, Mi-hyun (Cooperate Course for Climate Change, Sejong University) ;
  • Jeon, Eui-Chan (Department of Environmental & Energy, Sejong University)
  • 유정화 (세종대학교 환경에너지융합학과) ;
  • 박년배 (세종대학교 기후변화협동과정) ;
  • 조미현 (세종대학교 기후변화협동과정) ;
  • 전의찬 (세종대학교 환경에너지융합학과)
  • Received : 2012.05.25
  • Accepted : 2012.08.31
  • Published : 2012.09.29

Abstract

In this study, the S University's energy usage, greenhouse gas emissions situation and potential reduction amount were analyzed using a long-term energy analysis model, LEAP. In accordance with the VISION 2020 and university's own improvement plans, S University plans to complete a second campus through expansion constructions by 2020 and by allocating the needed land. Accordingly, increases in energy usage and greenhouse gas emissions seem inevitable. Hence, in this study, the calculations of potential reduction amount by 2020 were attempted through the use of LEAP model by categorizing the energy used based on usage types and by proposing usage typebased reduction methods. There were a total of 4 scenarios: a standard scenario that predicted the energy usage without any additional energy reduction activity; energy reduction scenario using LED light replacement; energy reduction scenario using high efficiency building equipment; and a scenario that combines these two energy reduction scenarios. As scenario-based results, it was ascertained that, through the scenario that had two other energy reduction scenarios combined, the 2020 greenhouse gas emissions amount would be 14,916 tons of $CO_2eq$, an increase of 43.7% compared to the 2010 greenhouse gas emissions amount. Put differently, it was possible to derive a result of about 23.7% reduction of the greenhouse gas emissions amount for S University's greenhouse gas emissions amount through energy reduction activities. In terms of energy reduction methods, changing into ultra-high efficiency building equipment would deliver the most amount of reduction.

에너지분석모형인 LEAP을 활용하여 국내 대학을 대상으로 에너지 사용 및 온실가스 배출 현황과 감축 잠재량을 분석하였다. 대학의 온실가스 감축 잠재량 산정을 위해 먼저 에너지 사용을 용도별로 구분하고, 용도별 저감 방법을 제시하여 LEAP 모형을 통해 2020년까지의 감축 잠재량을 산정하였다. 온실가스 감축 잠재량 예측을 위한 시나리오는 총 4개로, 추가적인 에너지 감축 활동이 없을 때의 에너지 수요량을 예측한 기준 시나리오와 LED로의 조명 교체, 고효율 기기로의 교체를 통한 에너지 저감 시나리오, 두 가지를 모두 시행한 통합 시나리오로 구성하였다. 시나리오에 따른 결과로는 통합 시나리오를 통해 2020년 온실가스 배출량이 $14,916tCO_2eq$로 2010년 대비 43.7% 증가하는 데 그치는 것을 확인할 수 있었다. 즉, S대학교의 온실가스 배출량은 에너지 사용 저감 노력으로 기준 시나리오 대비 약 23.7%의 온실가스 배출량을 줄일 수 있었다. 또한 전자제품의 효율 향상 연구를 통해 더 많은 에너지 절감 효과를 확인하였다. 이와 함께 대학 구성원들의 의식 변화 및 직접적인 에너지 절약 실천이 이루어진다면 그 효과를 극대화 시킬 수 있을 것으로 기대된다.

Keywords

Acknowledgement

Supported by : 한국에너지기술평가원(KETEP)