생체 시료 중 아세틸콜린 및 콜린에 대한 효소-분광학적 정량분석

Enzymatic Spectrophotometric Determinations of Acetylcholine and Choline in the Biological Samples

  • Nam, Myung-Hwa (Department of Chemistry, Sangmyung University) ;
  • Lee, Sung-Ho (Department of Green Life Science, Sangmyung University) ;
  • Kim, Ke-Tack (Department of Chemistry, Sangmyung University) ;
  • Hahn, Young-Hee (Department of Chemistry, Sangmyung University)
  • 투고 : 2012.06.20
  • 심사 : 2012.08.17
  • 발행 : 2012.08.31

초록

In order to determine acetylcholine and choline in the biological samples, the specific enzymes of acetylcholinesterase (AChE) and choline oxidase (ChO), which utilize acetylcholine and choline as substrates, were employed to convert substrates to $H_2O_2$. The produced $H_2O_2$ was coupled to 4-aminoantipyrine/phenol with peroxidase (PO) yielding quinoneimine dye which was measured at 508 nm. In the present enzymatic spectrophotometric analysis the product at the equilibrium state was measured considering accuracy, precision, time and cost of the analysis. The developed analytical method yielded good linearity (calibration curve; $A_{508}$=9534[acetylcholine]+0.009, correlation coefficient ($R^2$); 0.999) with detection limit of $1.11{\times}10^{-7}M$, reasonable precision (relative standard deviation; 0.10~1.62% at $2.5{\times}10^{-6}M{\sim}1.25{\times}10^{-4}M$) and accuracy (relative error; -0.24~0.97% at $4.13{\times}10^{-6}M{\sim}1.01{\times}10^{-4}M$) for acetylcholine chloride standard solution. The concentrations of acetylcholine and choline in human serum were found as $3.20{\times}10^{-5}M$ and $1.14{\times}10^{-4}M$, respectively. The brain tissues of Sprague-Dawley strain rat contained 9.82${\mu}g/g$ of acetylcholine and 6.53 ${\mu}g/g$ of choline in the cerebrum, while 7.37 ${\mu}g/g$ of acetylcholine and 5.34 ${\mu}g/g$ of choline in the cerebellum.

키워드

참고문헌

  1. Jamal, M., Ameno, K., Wang, W., Kumihashi, M., Ameno, S., Ikuo, U., Shinji, A. and Ijiri, I. : Inhibition of acetaldehyde metabolism decreases acetylcholine release in medial frontal cortex of freely moving rats. Brain Research 1039, 90 (2005).
  2. Hrdina, P. D. : Metabolism of brain acetylcholine and its modification by drugs. Drug Metab. Rev. 3, 89 (1974).
  3. Chang, Q. and Gold, P. E. : Switching memory system during learning: changes in patterns of brain acetylcholine release in the hippocampus and striatum in rats. J. Neurosci. 23, 3001 (2003).
  4. Uutela, P., Reinil, R., Pipponen, P., Ketola, R. A. and Kostiainen, R. : Analysis of acetylcholine and choline in microdialysis samples by liquid chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom. 19, 2950 (2005).
  5. Frolich, L., Dirr, A., Gotz, M. E., Gsell, W., Reichmann, H., Riederer, P. and Maurer, K. : Acetylcholine in human CSF: methodological considerations and levels in dementia of Alzheimer type. J. Neural Transm. 105, 961 (1998).
  6. Niwa, O., Horiuchi, T., Morita, M., Huang, T. and Kissinger, P. T. : Determination of acetylcholine and choline with platinum-black ultramicroarray electrodes using liquid chromatography with a post-column enzyme reactor. Analytica Chimica Acta 318, 167 (1996).
  7. Guerriere, A. and Palmisano, F. : An acetylcholinesterase/ cholineoxidase-based amperometric biosensor as a liquid chromatography detector for acetylcholine and choline determination in brain tissue homogenates. Anal. Chem. 73, 2875 (2001).
  8. Yamamoto, K., Sato, K., Chikuma, T. and Kato, T. : A highly sensitive and stable detection of acetylcholine by HPLCosmium- horseradish peroxidase redox polymer electrode coated on a gold radial flow ring disk. Analytica Chimica Acta 521, 209 (2004).
  9. Godoy, S., Leca-Bouvier, B., Boullanger, P., Blum, L. J. and Girard-Egrot, A. P. : Electrochemiluminescent detection of acetylcholine using acetylcholinesterase immobilized in a biomimetic Langmuir-Blodgett nanostructure. Sensors and Actuators B 107, 82 (2005).
  10. Hows, M. E. P., Organ, A. J., Murray, S., Dawson, L. A., Foxton, R., Heidbreder, C., Hughes, Z. A., Lacroix, L. and Shah, A. J. : High-performance liquid chromatography/tandem mass spectrometry assay for the rapid high sensitivity measurement of basal acetylcholine from microdialysates. J. Neuroscience Methods 121, 33 (2002).
  11. Campanella, L., Bonanni, A., Magri, A. L., Sorbo, A. and Tomassetti, M. : Determination of choline containing phospholipids in serum, bile and amniotic fluids by the derivative enzymatic-spectrophotometric method. J. Pharm. Biomed. Anal. 35, 399 (2004).
  12. Elnemma, E. M. : Spectrophotometric determination of hydrogen peroxide by a hydroquinone-aniline system catalyzed by molybdate. Bull. Korean Chem. Soc. 25, 127 (2004).
  13. Atsubara, C., Kudo, K., Kawashita, T. and Takamura, K. : Spectrophotometric determination of hydrogen peroxide with titanium reagent and its application to the determination of serum glucose using glucose oxidase. Anal. Chem. 57, 1107 (1985).
  14. Huana, H., Kuan, J. W. and Guilbault, G. G. : Fluorometric enzymatic determination of total cholesterol in serum. Clin. Chem. 21, 1605 (1975).
  15. Lazaro, F., Luque de Castro, M. D. and Valcarcel, M. : Individual and simultaneous determination of ethanol and acetaldehyde in wines by flow injection analysis and immobilized enzymes. Anal. Chem. 59, 1859 (1987).
  16. Czaban, J. D. and Rechnitz, G. A. : Fabrication and evaluation of glass microbulb electrodes. Anal. Chem. 47, 1792 (1975).
  17. Vreeke, M., Maidan, R. and Heller, A. : Hydrogen peroxide and ${\beta}$-nicotinamide adenine dinucleotide sensing amperometric electrodes based on electrical connection of horseradish peroxidase redox centers to electrodes through a threedimensional electron relaying polymer network. Anal. Chem. 64, 3084 (1992).
  18. Willian, F. Brunsman, A., Huntigtion, J., Johnson, J. and Newman, D. : Amperometric-oxidase enzyme probes for biochemical analysis. Yellow Springs, Ohio, U.S.A. (1976).
  19. Allain, C. C., Poon, L. S., Chan, C. S. G., Richmond, W. and Fu, P. C. : Enzymatic determination of total serum cholesterol. Clin. Chem. 20, 470 (1974).
  20. Polson, C., Sarkar, P., Incledon, B., Raguvaran, V. and Grant, R. : Optimization of protein precipitation based upon effectiveness of protein removal and ionization effect in liquid chromatography - tandem mass spectrometry. J. Chromatogr. B 785, 263 (2003)
  21. Harris, D. C. : Quantitative Chemical Analysis, 7th Ed., Freeman and Company, New York, U.S.A. p. 86 (2007).
  22. Skoog, D. A., West, D. M., Holler, F. J. and Crouch, S. R. : Fundamentals of Analytical Chemistry, 8th Ed., Thomson, U.S.A. p. 793 (2004).