DOI QR코드

DOI QR Code

A Study of factor analysis of immune building system for microbiological safety

실내 미생물 안전을 위한 면역건물기술 인자들의 상호작용에 관한 연구

  • Choi, Sang-Gon (Depat. of Bilding Services, Yuhan University) ;
  • Jang, Sung-Min (Dept. of Naval Architecture & Mechanics, Chosun College of Science & Tec.)
  • 최상곤 (유한대학교 건축설비과) ;
  • 장성민 (조선이공대학 선박해양.기계과)
  • Received : 2012.07.20
  • Accepted : 2012.08.30
  • Published : 2012.09.30

Abstract

In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program contam2.4. This model include immune building system(disinfection system) which is consist of dilution, Filter Technology and UVGI(ultra violet germicidal irrdiation). In this study experiments design method used for estimating interaction of HRV air change rate, UVGI air change rate and UVGI grade. Result show that HRV air change rate and UVGI air change rate is most influence factor for remove rate. also Interaction of HRV air change rate and UVGI air change rate is ost influence factor for remove rate.

Keywords

References

  1. S. G. Choi, J. K. Hong, 2005, The study on the performance estimation of UVC air sterilizer for preventing transmission of air borne contagion ,v.17n.6. , Journal of SAREK
  2. S. G. Choi, K. S. Park, Y. S. Yoon, J. K. Hong, 2006, The study on the performance of air sterilization of multistoried apartment by the multizone modeling. Summer conference of SAREK . pp. 319 - 324
  3. S. G. Choi, H. w. Lee, J. K. Hong, 2006, The study on the multizone modeling for preventing transmission of air borne contagion. Summer conference of SAREK . pp. 429 - 435
  4. W.H.Yang, Y.S.Tarng., 1998, "Design optimization of cutting parameters for turning operations based on the Taguchi method," Journal of Materials Processing Technology 84, pp122-129 https://doi.org/10.1016/S0924-0136(98)00079-X
  5. Vance, J. M., 1988, "Rotordynamics of Turbomachinery," John Wiley & Sons, Inc., NewYork.,
  6. ASHRAE, ASHRAE Handbook 1997. American Society Heating, Refrigerating and Air-Conditioning Engineers,Inc., Atlanta, GA. Chapter25.
  7. Bratbak, G. A., Dundas, I. 1984. "Bacterial dry matter content and biomass estimations." Appl. Environ. Microbiol., 48, 755-757.
  8. P. Y. CHAO, Y. D. HWANG, 1997, "An improved Taguchi's method in design of experiments for milling CFRP composite," INT. J. PROD. RES, Vol. 35, No. 1, pp. 51-66. https://doi.org/10.1080/002075497195975