Posterior Cervical Fixation with a Nitinol Shape Memory Loop for Primary Surgical Stabilization of Atlantoaxial Instability : A Preliminary Report

  • Kim, Duk-Gyu (Department of Neurosurgery, Research Institute of Clinical Medicine, Institute for Medical Sciences, Chonbuk National University Medical School and Hospital) ;
  • Eun, Jong-Pil (Department of Neurosurgery, Research Institute of Clinical Medicine, Institute for Medical Sciences, Chonbuk National University Medical School and Hospital) ;
  • Park, Jung-Soo (Department of Neurosurgery, Research Institute of Clinical Medicine, Institute for Medical Sciences, Chonbuk National University Medical School and Hospital)
  • Received : 2012.02.21
  • Accepted : 2012.07.06
  • Published : 2012.07.28

Abstract

Objective : To evaluate a new posterior atlantoaxial fixation technique using a nitinol shape memory loop as a simple method that avoids the risk of vertebral artery or nerve injury. Methods : We retrospectively evaluated 14 patients with atlantoaxial instability who had undergone posterior C1-2 fusion using a nitinol shape memory loop. The success of fusion was determined clinically and radiologically. We reviewed patients' neurologic outcomes, neck disability index (NDI), solid bone fusion on cervical spine films, changes in posterior atlantodental interval (PADI), and surgical complications. Results : Solid bone fusion was documented radiologically in all cases, and PADI increased after surgery (p<0.05). All patients remained neurologically intact and showed improvement in NDI score (p<0.05). There were no surgical complications such as neural tissue or vertebral artery injury or instrument failure in the follow-up period. Conclusion : Posterior C1-2 fixation with a nitinol shape memory loop is a simple, less technically demanding method compared to the conventional technique and may avoid the instrument-related complications of posterior C1-2 screw and rod fixation. We introduce this technique as one of the treatment options for atlantoaxial instability.

Keywords

References

  1. Abou Madawi A, Solanki G, Casey AT, Crockard HA : Variation of the groove in the axis vertebra for the vertebral artery. Implications for instrumentation. J Bone Joint Surg Br 79 : 820-823, 1997 https://doi.org/10.1302/0301-620X.79B5.7566
  2. Anderson LD, D'Alonzo RT : Fractures of the odontoid process of the axis. J Bone Joint Surg Am 56 : 1663-1674, 1974 https://doi.org/10.2106/00004623-197456080-00017
  3. Bahadur R, Goyal T, Dhatt SS, Tripathy SK : Transarticular screw fixation for atlantoaxial instability-modified Magerl's technique in 38 patients. J Orthop Surg Res 5 : 87, 2010 https://doi.org/10.1186/1749-799X-5-87
  4. Blauth M, Richter M, Lange U : [Trans-articular screw fixation of C1/C2 in atlanto-axial instability. Comparison between percutaneous and open procedures]. Orthopade 28 : 651-661, 1999
  5. Brantigan JW, Steffee AD : A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients. Spine (Phila Pa 1976) 18 : 2106-2107, 1993 https://doi.org/10.1097/00007632-199310001-00030
  6. Braun JT, Akyuz E, Udall H, Ogilvie JW, Brodke DS, Bachus KN : Three-dimensional analysis of 2 fusionless scoliosis treatments : a flexible ligament tether versus a rigid-shape memory alloy staple. Spine (Phila Pa 1976) 31 : 262-268, 2006 https://doi.org/10.1097/01.brs.0000197569.13266.fe
  7. Brooks AL, Jenkins EB : Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am 60 : 279-284, 1978 https://doi.org/10.2106/00004623-197860030-00001
  8. Coyne TJ, Fehlings MG, Wallace MC, Bernstein M, Tator CH : C1-C2 posterior cervical fusion : long-term evaluation of results and efficacy. Neurosurg 37 : 688-692; discussion 692-693, 1995 https://doi.org/10.1227/00006123-199510000-00012
  9. Dickman CA, Sonntag VK, Papadopoulos SM, Hadley MN : The interspinous method of posterior atlantoaxial arthrodesis. J Neurosurg 74 : 190-198, 1991 https://doi.org/10.3171/jns.1991.74.2.0190
  10. Grob D, Jeanneret B, Aebi M, Markwalder TM : Atlanto-axial fusion with transarticular screw fixation. J Bone Joint Surg Br 73 : 972-976, 1991
  11. Jeanneret B, Magerl F : Primary posterior fusion C1/2 in odontoid fractures : indications, technique, and results of transarticular screw fixation. J Spinal Disord 5 : 464-475,1992 https://doi.org/10.1097/00002517-199212000-00012
  12. Kim YS, Zhang HY, Moon BJ, Park KW, Ji KY, Lee WC, et al. : Nitinol spring rod dynamic stabilization system and Nitinol memory loops in surgical treatment for lumbar disc disorders : short-term follow up. Neurosurg Focus 22 : E10, 2007
  13. Magerl F, Seemann PS : Stable posterior fusion of the atlas and axis by transarticular screw fixation in Kehr P, Weidner A (eds) : Cervical spine I Vol 1. New York : Springer, 1987, Vol 1, pp322-327
  14. Miyata M, Neo M, Ito H, Yoshida M, Miyaki K, Fujibayashi S, et al. : Is rheumatoid arthritis a risk factor for a high-riding vertebral artery? Spine (Phila Pa 1976) 33 : 2007-2011, 2008 https://doi.org/10.1097/BRS.0b013e31817c6bf7
  15. Sanders JO, Sanders AE, More R, Ashman RB : A preliminary investigation of shape memory alloys in the surgical correction of scoliosis. Spine (Phila Pa 1976) 18 : 1640-1646, 1993 https://doi.org/10.1097/00007632-199309000-00012
  16. Stillerman CB, Wilson JA : Atlanto-axial stabilization with posterior transarticular screw fixation : technical description and report of 22 cases. Neurosurgery 32 : 948-954; discussion 954-955, 1993 https://doi.org/10.1227/00006123-199306000-00011
  17. Stokes JK, Villavicencio AT, Liu PC, Bray RS, Johnson JP : Posterior atlantoaxial stabilization : new alternative to C1-2 transarticular screws. Neurosurg Focus 12 : E6, 2002
  18. Vender JR, Rekito AJ, Harrison SJ, McDonnell DE : The evolution of posterior cervical and occipitocervical fusion and instrumentation. Neurosurg Focus 16 : E9, 2004
  19. Wang C, Yan M, Zhou H, Wang S, Dang G : Atlantoaxial transarticular screw fixation with morselized autograft and without additional internal fixation : technical description and report of 57 cases. Spine (Phila Pa 1976) 32 : 643-646, 2007 https://doi.org/10.1097/01.brs.0000257539.75693.cc
  20. Wright NM, Lauryssen C : Vertebral artery injury in C1-2 transarticular screw fixation : results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. J Neurosurg 88 : 634-640, 1998 https://doi.org/10.3171/jns.1998.88.4.0634
  21. Yoshida M, Neo M, Fujibayashi S, Nakamura T : Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw. Spine (Phila Pa 1976) 31 : E513-E517, 2006 https://doi.org/10.1097/01.brs.0000224516.29747.52
  22. Yu DK, Heo DH, Cho SM, Choi JH, Sheen SH, Cho YJ : Posterior cervical fixation with nitinol shape memory loop in the anterior-posterior combined approach for the patients with three column injury of the cervical spine : preliminary report. J Korean Neurosurg Soc 44 : 303-307, 2008 https://doi.org/10.3340/jkns.2008.44.5.303

Cited by

  1. Radicular Pain due to Subsidence of the Nitinol Shape Memory Loop for Stabilization after Lumbar Decompressive Laminectomy vol.57, pp.1, 2015, https://doi.org/10.3340/jkns.2015.57.1.61
  2. Usefulness of titanium mesh cage for posterior C1–C2 fixation in patients with atlantoaxial instability vol.96, pp.36, 2017, https://doi.org/10.1097/md.0000000000008022
  3. Formability of Annealed Ni-Ti Shape Memory Alloy Sheet vol.324, pp.None, 2012, https://doi.org/10.1088/1757-899x/324/1/012038
  4. Study on shape memory effect of hot deep-drawn NI-TI shape memory alloy sheet part vol.2020, pp.1, 2021, https://doi.org/10.1088/1742-6596/2020/1/012002