References
- Cohen S, Hargreaves KM. Pathways of the pulp. 9th ed. St Louis: Mosby Elsevier Co.; 2006. p996.
- Alhadainy HA. Root perforations. A review of literature. Oral Surg Oral Med Oral Pathol 1994;78:368-374.
- Sunada I. New method for measuring the length of the root canal. J Dent Res 1962;41:375-387.
- Trope M, Rabie G, Tronstad L. Accuracy of an electronic apex locator under controlled clinical conditions. Endod Dent Traumatol 1985;1:142-145.
- Topuz O, Uzun O, Tinaz AC, Bodrumlu E, Görgül G. Accuracy of two apex-locating handpieces in detecting simulated vertical and horizontal root fractures. J Endod 2008;34:310-313.
- Angwaravong O, Panitvisai P. Accuracy of an electronic apex locator in primary teeth with root resorption. Int Endod J 2009;42:115-121.
- Goldberg F, Frajlich S, Kuttler S, Manzur E, Briseño- Marroquín B. The evaluation of four electronic apex locators in teeth with simulated horizontal oblique root fractures. J Endod 2008;34:1497-1499.
- Gordon MP, Chandler NP. Electronic apex locators. Int Endod J 2004;37:425-437.
- Nahmias Y, Aurelio JA, Gerstein H. Expanded use of the electronic canal length measuring devices. J Endod 1983;9:347-349.
- Fuss Z, Assooline LS, Kaufman AY. Determination of location of root perforations by electronic apex locators. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1996;82:324-329.
- Kim DW, Nam KC, Lee SJ. Development of a frequencydependent- type apex locator with automatic compensation. Crit Rev Biomed Eng 2000;28:473-479.
- Jenkins JA, Walker WA 3rd, Schindler WG, Flores CM. An in vitro evaluation of the accuracy of the root ZX in the presence of various irrigants. J Endod 2001;27:209-211.
- Kaufman AY, Keila S, Yoshpe M. Accuracy of a new apex locator: an in vitro study. Int Endod J 2002;35:186-192.
- Jeansonne MJ, White RR. A comparison of 2.0% chlorhexidine gluconate and 5.25% sodium hypochlorite as antimicrobial endodontic irrigants. J Endod 1994;20:276-278.
- Siqueira JF Jr, de Uzeda M. Intracanal medicaments: evaluation of the antibacterial effects of chlorhexidine, metronidazole, and calcium hydroxide associated with three vehicles. J Endod 1997;23:167-169.
- Mohammadi Z, Abbott PV. The properties and applications of chlorhexidine in endodontics. Int Endod J 2009;42:288-302.
- Kaufman AY, Keila S. Hypersensitivity to sodium hypochlorite. J Endod 1989;15:224-226.
- Dametto FR, Ferraz CC, Gomes BP, Zaia AA, Teixeira FB, de Souza-Filho FJ. In vitro assessment of the immediate and prolonged antimicrobial action of chlorhexidine gel as an endodontic irrigant against Enterococcus faecalis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2005;99:768-772.
- Monika CM, Froner IC. A scaning electron microscopic evaluation of different root canal irrigation regimens. Braz Oral Res 2006;20:235-240.
- Vianna ME, Gomes BP, Berber VB, Zaia AA, Ferraz CC, de Souza-Filho FJ. In vitro evaluation of the antimicrobial activity of chlorhexidine and sodium hypochlorite. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2004;97:79-84
- Joesten MD, Hogg JL, Castellion ME. The world of chemistry: essentials. 4th ed. Belmont, CA: Brooks Cole; 2004. p461.
- Donnelly JC. A simplified model to demonstrate the operation of electronic root canal measuring devices. J Endod 1993;19:579-580.
- Ingle JI, Bakland LK. Endodontics. 5th ed. Hamilton, London: Williams & Wilkins; 2002. Chapter 13, Outcome of endodontic treatment and retreatment; p747.
- Kim M, Kim B, Yoon S. Effect on the healing of periapical perforations in dogs of the addition of growth factors to calcium hydroxide. J Endod 2001;27:734-737.
- Ingle JI, Backland LK, Baumgartner JC. Ingle's endodontics. 6th ed. Hamilton: Decker; 2008. p852-853.
- Ferry JD. Viscoelastic Properties of Polymers. 3rd ed. New York: Wiley; 1980. p529.
- Erdemir A, Eldeniz AU, Ari H, Belli S, Esener T. The influence of irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece. Int Endod J 2007;40:391-397.
- Shabahang S, Goon WW, Gluskin AH. An in vivo evaluation of Root ZX electronic apex locator. J Endod 1996;22:616-618.
Cited by
- Consistency of electronic measurements of endodontic working length when using multiple devices from the same manufacturer—an in vitro study vol.22, pp.9, 2018, https://doi.org/10.1007/s00784-018-2404-3
- Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study vol.16, pp.6, 2019, https://doi.org/10.4103/1735-3327.270779
- Confort visual en oficinas, factor temporal en la evaluación de deslumbramiento vol.72, pp.557, 2020, https://doi.org/10.3989/ic.67992
- The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators vol.20, pp.1, 2012, https://doi.org/10.1186/s12903-019-0994-z
- Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph-In Vitro Study vol.2021, pp.None, 2012, https://doi.org/10.1155/2021/5563426