Mechanical Properties of High Strength Shear Connector

고강도(高强度) 스터드 볼트의 역학적 특성에 관한 연구

  • 엄철환 (위덕대학교 건축소방안전학과)
  • Received : 2012.04.27
  • Accepted : 2012.10.25
  • Published : 2012.10.31

Abstract

The headed studs those are used extensively for steel-composite construction is specified as SS400 at the current Korean Standard specification considering the welding condition. And the corresponding equation for the shear force calculation is limited for the use of compression strength of concrete below $300kg/cm^2$. However, it is expected that the high strengthening and precast of both steel and concrete due to the necessity of shear connector or other connecting material for the combination of steel and concrete. Therefore, the experimental results obtained during the development process of high strength stud for the connection of high strength concrete and the steel member are reported in this paper. Also the effectiveness of newly developed shear connector using pipe to increase the stiffness of a stud is verified by comparing both the stiffness and the strength with common stud bolt through the welding ability, mechanical characteristics and experimental investigation.

Keywords

References

  1. 대한건축학회, 건설교통부 고시 건축구조설계기준 및 해설, 2006.
  2. 日本建築學會, 各種合成構造設計指針同解說, 1985.
  3. AISC, MANUAL OF STEEL CONSTRUCTION-LOAD&RESISTANCE FACTOR DESIGN Volume 1, Second Edition, 1998.
  4. 井上一朗, 金 喆煥, 嚴 喆煥, 宇野蝪芳, 富樫 洋, "高强度.高剛性スタツドの開發硏究(パイプスタツドの豫備實驗)", 日本建築學會近畿支部硏究報告集, 1990年5月.