초록
This research is an illustrative research to verify the thermo environmental change created after introduction of indoor pond through abridged model test and simulation analysis. Especially, temperature and comfort level are analyzed by adjusting factors like size of water space, distance length, and location. Summary of the research is as follows. First, the most effective size of water space is 7% of the indoor size, from southern side. Temperature reduction effect is about $1.6^{\circ}C$(5.5%), and for the comfort level, it is found that pmv index increases 8%. Second, based on the simulation of distance length with the sphere, it is more effective as it is close to the surface. If distance length is more than 0.5m, there is no effect on reduction of temperature and comfort level of indoor environment. Lastly, for the analysis by location of the introduced water space, simulation is undertaken by dividing the water space (14% of the indoor size) with front, side, rear and center types. Temperature reduction effect is found to be : front type ($-1.53^{\circ}C$), side type ($-0.82^{\circ}C$), rear type ($-0.44^{\circ}C$), center type ($-0.28^{\circ}C$), respectively. The indoor environment change data by introduction of water space, found in this research, is at initial phase, but it is deemed to be a basic data to refer when planning actual water space.