Abstract
Results of the analysis of the structural behavior of axially loaded nodes in freeform structure were not fully understood due to certain difficulties, including the application of various welding and bolting types. In this study, a node of single layered freeform structure was tested to determine its structural behavior when subjected to axial loads. The tests were classified into node ball tests to evaluate the center of the node subjected to cyclic and monotonic loading. The node part tests were also conducted to evaluate the whole node subjected to monotonic loading. The test showed that the node ball is safe with the tensile force, but the node ball needs to increase its strength with the node loaded compressive force due to the additional bending moment of the node ball's asymmetric form.
프리폼 구조의 노드는 용접 및 볼트 접합 특성을 반영하는 것이 어려워 구조 성능을 해석적으로 평가하는 것에는 한계가 있다. 본 연구에서는 축하중을 받는 프리폼 구조 노드의 구조 거동을 알아보고 성능을 평가하기 위해 실험을 수행하였다. 실험은 노드 중심부의 성능을 알아보기 위한 노드 볼 실험과 노드부 전체의 내력 평가를 위한 노드부 실험으로 구분된다. 노드 볼 구조 성능 평가에서는 축력에 대한 단조가력과 반복가력 실험을 하였고 노드부 구조 성능 평가에서는 단조가력 실험을 수행하였다. 실험 결과 노드 접합부 설계가 적합하므로 실제 구조물에 인장 발생 시 노드 볼이 충분한 내력을 가지며 안전할 것으로 판단되나 압축 발생 시 노드 볼 형상의 비대칭에 따른 모멘트 발생으로 내력이 저하된 현상을 보였다.