DOI QR코드

DOI QR Code

Performance Study of Wind Augmentation Device for Building-integrated Wind Power

건물 풍력발전을 위한 집풍장치 성능 연구

  • Received : 2011.09.23
  • Accepted : 2012.02.22
  • Published : 2012.08.01

Abstract

This study is performance estimation of wind augmentation device for BiWP(Building-integrated Wind Power) which recently attracts attention as a local power. various structures are installed on a rooftop of residential complex buildings. Changing a profile of these, we designed a configuration that is able to capture much air and increase exit velocity. To estimate wind augmented effect of this device, we compared numerical analysis results with wind tunnel test results. Results show that exit velocity is increased from 24% to 60% by wind augmented device on a rooftop of building.

Keywords

References

  1. 윤종호, 2008, "건물일체형 풍력발전 기술현황," 한국건축친환경설비학회지, 제2권, 제1호, pp. 54-58.
  2. 김용이, 2011, "건물 일체형 풍력시스템 디자인 고찰," 유체기계저널, 제14권, 제4호, pp. 64-69.
  3. 박은태, 강병근, 2007, "친환경 건축물 인증 아파트 단지 일조환경 분석에 관한 연구," 대한건축학회지, 제23권, 제 9호, pp. 3-13.
  4. Cygnus-Mill 성능곡선, http://www.wind-smile.com/news/products/turbine-200w.htm

Cited by

  1. 외기유인형 주방·욕실 배기구의 기류측정 분석 vol.32, pp.6, 2012, https://doi.org/10.7836/kses.2012.32.6.076
  2. 건물 옥상외기와 실내배기를 활용한 풍력발전시스템 적용 연구 vol.34, pp.1, 2012, https://doi.org/10.7836/kses.2014.34.1.072