References
- Woias, P., 2005, "Micropumps-past, Progress and Future Prospects," Sensors and Actuators B, Vol. 105, No. 1, pp. 28-38. https://doi.org/10.1016/S0925-4005(04)00108-X
- Smits, J. G., 1990, "Piezoelectric Micropump with Three Valves Working Peristaltically," Sensors and Actuators A, Vol. 21-23, No. 1-3, pp. 203-206.
- van Lintel, H. T. G., van De Pol, F. C. M., and Bouwstra, S., 1988, "A Piezoelectric Micropump based on Micromachining of Silicon," Sensors and Actuators A, Vol. 15, No. 2, pp. 153-167. https://doi.org/10.1016/0250-6874(88)87005-7
- Yang, X., Zhou, Z., Cho, H., and Luo, X., 2006, "Study on a PZT-actuated Diaphragm Pump for Air Supply for Micro Fuel Cells," Sensors and Actuators A, Vol. 130-131, pp. 531-536. https://doi.org/10.1016/j.sna.2005.12.021
- Kan, J., Yang, Z., Peng, T., Cheng, G., and Wu, B., 2005, "Design and Test of a High-performance Piezoelectric Micropump for Drug Delivery," Sensors and Actuators A, Vol. 121, No. 1, pp. 156-161. https://doi.org/10.1016/j.sna.2004.12.002
- Liua, G., Shen, C., Yang, Z., Cai, X., and Zhang, H., 2010, "A Disposable Piezoelectric Micropump with High Performance for Closed-loop Insulin Therapy System," Sensors and Actuators A, Vol. 163, No. 1, pp. 291-296. https://doi.org/10.1016/j.sna.2010.06.030
- Cooney, C. G., and Towe, B. C., 2004, "A Thermopneumatic Dispensing Micropump," Sensors and Actuators A, Vol. 116, No. 3, pp. 519-524. https://doi.org/10.1016/j.sna.2004.05.015
- Jun, D. H., Sim, W. Y., and Yang, S. S., 2007, "A Novel Constant Delivery Thermopneumatic Micropump using Surface Tensions," Sensors and Actuators A, Vol. 139, No. 1-2, pp. 210-215. https://doi.org/10.1016/j.sna.2007.04.038
- Van de Pol, F. C. M., Van Lintel, H. T. G., Elwenspoek, M., and Fluitman, J. H. J., 1990, "A Thermopneumatic Micropump based on Micro-engineering Techniques," Sensors and Actuators A, Vol. 21, No. 1-3, pp. 198-202. https://doi.org/10.1016/0924-4247(90)85038-6
- Luo, A., and Xia, A., 2005, "A Novel Valve-less Synthetic-jet-based Micro-pump," Sensors and Actuators A, Vol. 122, No. 1, pp. 131-140. https://doi.org/10.1016/j.sna.2005.03.062
- Bourouina, T., Bosseboeuf, A., and Grandchamp, J. P., 1997, "Design and Simulation of an Electrostatic Micropump for Drug-delivery Applications," J. Micromech. Microeng., Vol. 7, No. 3, pp. 186-188. https://doi.org/10.1088/0960-1317/7/3/028
- Teymoori, M. M., and Abbaspour-Sani, E., 2005, "Design and Simulation of a Novel Electrostatic Peristaltic Micromachined Pump for Drug Delivery Applications," Sensors and Actuators A, Vol. 117, No. 2, pp. 222-229. https://doi.org/10.1016/j.sna.2004.06.025
- Tsai, J., and Lin, L., 2002, "Active Microfluidic Mixer and Gas Bubble Filter Driven by Thermal Bubble Micropump," Sensors and Actuators A, Vol. 97-98, pp. 665-671. https://doi.org/10.1016/S0924-4247(02)00031-6
- Chan, S., Chen, C., and Liu, C., 2010, "A Bubbleactivated Micropump with High-frequency Flow Reversal," Sensors and Actuators A, Vol. 163, No. 2, pp. 501-509. https://doi.org/10.1016/j.sna.2010.08.026
- Oshio, K., Watanabe, H., Song, Y., Verkman, A. S., and Manley, G. T., 2005, "Reduced Cerebrospinal Fluid Production and Intracranial Pressure in Mice Lacking Choroid Plexus Water Channel Aquaporin-1," FASEB J, Vol. 19, No. 1, pp. 76-78.
Cited by
- 자기공명영상 동적검사 시 조영제 역류방지용 밸브의 유용성 vol.20, pp.6, 2012, https://doi.org/10.5392/jkca.2020.20.06.439