DOI QR코드

DOI QR Code

A Study on Visual Comfort for Compound Lighting Control Method of Applied Daylighting

자연채광의 응용에 의한 합성조명방식의 시각적 쾌적성에 관한 연구

  • Han, Sang-Pil (Dept. of Fire Protection and Safety, Sangji Youngseo College) ;
  • Jeon, Yong-Han (Dept. of Fire Protection and Safety, Sangji Youngseo College) ;
  • Han, Sang-Chul (Dept. of Fire Protection and Safety, Sangji Youngseo College)
  • 한상필 (상지영서대학교 소방안전과) ;
  • 전용한 (상지영서대학교 소방안전과) ;
  • 한상철 (상지영서대학교 소방안전과)
  • Received : 2012.06.04
  • Accepted : 2012.06.26
  • Published : 2012.06.30

Abstract

The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, the two variables were used in this study. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

Keywords

References

  1. Tiller. D.K and Veich. J. A., Perceived room brightness : Pilot study on the effect of luminance distribution, Lighting Res. Technol. Vol.27, No.2,1995.
  2. Han. S. P., A study on light control method for harmonization of Daylighting and artificial lighting, Journal of AIK, Vol. 26, No.8, 2010.8
  3. Han. S. P., The effect of conpound Ratio for daylighting ad artificial lighting in visual impression, Journal of AIK, Vol. 26, No.12, 2010.12
  4. KW Houser, DK Tiller, CA Vernecker and RC Mistrick.,The subjective responseto linear fluorescent direct/indirect lighting systems, Lightings Res. Technol. Vol.34, No.3, 2002
  5. A. Pellefrino., Assessment of artificial lighting parameters in a visual comfort perspective, Lightings Res. Technol. Vol. 31, No.3, 1999
  6. P.L. Vrabel, C.A. Bernecher and R.G. Mistrick.., Visual performance and visual clarify under electric light sources, Part I: Visual Performance, J of the IES, Vol. 24, No.1, 2000.

Cited by

  1. A Study on Analysis of Space Evaluation Using the Luminance Distribution Images vol.33, pp.5, 2013, https://doi.org/10.7836/kses.2013.33.5.076
  2. A Study on Daylight Control Method for Securing Visual Comfort and Reducing Lighting Loads on Interior Lighting Environment vol.32, pp.6, 2012, https://doi.org/10.7836/kses.2012.32.6.100