Canopy Model 적용을 통한 도심지 풍환경 예측 CFD 시뮬레이션 결과의 보정

Modification of CFD results for Wind Environment in Urban area with Tree Canopy Model

  • 투고 : 2012.06.04
  • 심사 : 2012.06.26
  • 발행 : 2012.06.30

초록

Recently rapid urbanization facilitates development of high-rise building complex including apartment and office building in urban area. Many problems related with high -rise building are reported. Especially, unpleasant strong winds in pedestrian area are frequently encountered around the high-rise building. CFD simulation methods are used to analyze the wind environment of pedestrian level in high-rise building block. However, the results show differences between CFD and measurement. This difference is attributed to improper use of CFD. Conventional CFD simulation for wind environment around high-rise building does not describe the effect of trees, shrubs and plants near ground which affect the wind environment of pedestrian level. Canopy model can be used to reproduce the aerodynamic effects of trees, shrubs and plants near ground. In this paper, CFD simulation methods coupled with the tree canopy model to predict wind environment of pedestrian level in high-rise residential building block were suggested and the validity was analyzed by comparison between measurement and CFD results.

키워드

참고문헌

  1. Wind Engineering Institute, 2005. Basics for wind environment around the high-rise building, Kajima publishing co., pp. 30-31.
  2. Penwarden, A.D., 1973. Acceptablewind speedsintowns, Building Science 8, pp. 259-267 https://doi.org/10.1016/0007-3628(73)90008-X
  3. Isyumov, N. and. Davenport A. G., 1975. Theground levelwind environmentin built-up areas, Prc. 4th Int. Conf. on Wind Effects on Buildings and Structures, London, pp.420-422.
  4. Murakami S.et.al.,1981, Investigation on statistical characteristics of windat ground leveland criteria forassessing wind-induced discomfort : Part-ILong-term observation of wind at ground levelin built-uparea, Transactions of the Architectural Institute of Japan.(310), pp. 88-97 [in Japanese]
  5. Murakami S.et.al., 1993, Investigation on wind environment for renovation project at Kyushima area in Nagoya, Architectural Institute of Japan [inJapanese]
  6. P.J. Jones, G. E. Whittle, 2003. Computational fluid dynamics for building air flow prediction?current status and capabilities, Building and Environmnet Vol. 27(3), pp. 321-338.
  7. Kim D.H. et al., 2006. CFD based prediction of wind road in site planning of apartment housing, Annual Conference Proceeding of the Architectural Institute of Korea BookII, pp. 665-668.
  8. HongI. P., Song D. S., 2012. A Studyon Inlet Flow Profilein CFD Simulationfor Predicting Wind Environmentin Urban Area, Journalof AIK Vol. 28(1), pp. 311-318
  9. Tominaga Y., 2008. AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings, Journal of Wind Engineering and Industrial Aerodynamics 96,pp.1749-1761. https://doi.org/10.1016/j.jweia.2008.02.058
  10. Mochida A., Tabata Y., Iwata T., Yoshino H., 2008. Examining tree canopy models for CFD prediction of wind environment at pedestrian level, Journak of Wind Engineering and Industrial Aerodynamics 96, pp.1667-1677 https://doi.org/10.1016/j.jweia.2008.02.055
  11. Star CCM+ 5.06 Training Manual
  12. John S. Irwin, 1979. A theoretical variation of the wind profile power-law exponent as a function of surfaceroughness and stability, Atmospheric Environment Vol. 13(1), pp. 191-194 https://doi.org/10.1016/0004-6981(79)90260-9
  13. Qingyan Chen, 2004. Using Computational Tools to Factor Wind into Architectural Environment Design, Energy and Buildings, Vol.36, pp.1197-1209. https://doi.org/10.1016/j.enbuild.2003.10.013
  14. Xianting Li, Zhen Yu, Bin Zhao, Ying Li, 2005. Numerical analysis of outdoor thermal environment around buildings, Building and Environment Vol. 40 pp.853-866. https://doi.org/10.1016/j.buildenv.2004.08.022

피인용 문헌

  1. 건물 성능의 정량적 평가를 위한 표준주택모델 선정에 관한 연구 - 최근 15년 이내의 공동주택을 중심으로 - vol.37, pp.1, 2012, https://doi.org/10.5659/jaik.2021.37.1.157