DOI QR코드

DOI QR Code

Thermographic Detection of Surface Crack Using Holomorphic Function of Thermal Field

  • Kim, No-Hyu (Department of Mechatronic Engineering, Korea University of Technology and Education) ;
  • Lim, Zong-Soo (NDE Division, Research Institute of Industrial Science and Technology)
  • 투고 : 2012.05.11
  • 심사 : 2012.06.08
  • 발행 : 2012.06.30

초록

This paper describes an analytic method for infrared thermography to detect surface cracks in thin plates. Traditional thermographic method uses the spatial contrast of a thermal field, which is often corrupted by noise in the experiment induced mainly by emissivity variations of target surfaces. This study developed a robust analytic approach to crack detection for thermography using the holomorphic function of a temperature field in thin plate under steady-state thermal conditions. The holomorphic function of a simple temperature field was derived for 2-D heat flow in the plate from Cauchy-Riemann conditions, and applied to define a contour integral that varies depending on the existence and strength of singularity in the domain of integration. It was found that the contour integral at each point of thermal image reduced the noise and temperature variation due to heat conduction, so that it provided a clearer image of the singularity such as cracks.

키워드

참고문헌

  1. T. Sakagami and S. Kubo, "Development of a new non-destructive testing technique for quantitative evaluations of delamination defects in concrete structures based on phase delay measurement using lock-in thermography," Infrared Physics & Technology, Vol. 43, pp. 211-218 (2002) https://doi.org/10.1016/S1350-4495(02)00141-X
  2. T. Sakagami and S. Kubo, "Development of a new crack identification technique based on near-tip singular electrothermal field measured by lock-in infrared thermography," JSME International Journal, Series A, Vol. 44, No. 4, pp. 528-534 (2001) https://doi.org/10.1299/jsmea.44.528
  3. I. Z. Abidin, G. Tian, J. Wilson, S. Yang and D. Almond, "Quantitative evaluation of angular defects by pulsed eddy current thermography," NDT & E International 43(7), pp. 537-546 (2010) https://doi.org/10.1016/j.ndteint.2010.05.010
  4. G. Walle and U. Netzelmann, "Thermographic crack detection in ferritic steel components using inductive heating," Proc. of ECNDT, Tu.4.8.5 (2006)
  5. G. Zenzinger et al., "Thermographic crack detection by eddy current excitation," Nondestructive Testing and Evaluation, 22, pp. 101-111 (2007) https://doi.org/10.1080/10589750701447920
  6. S. D. Holland and J. Renshaw, "Physicsbased image enhancement for infrared thermography," NDT&E International 43(5), pp. 440-445 (2010) https://doi.org/10.1016/j.ndteint.2010.04.004
  7. T. Li, D. P. Almond and D. A. S. Rees, "Crack imaging by scanning pulsed laser spot thermography," NDT&E International 18(1), pp. 117-123 (2011)
  8. J. R. Lesniak and D. J. Bazile, "Forceddiffusion thermography technique and projector design," Proc. SPIE Vol. 2766, pp. 210-217 (1996)
  9. T. Lee, N. Kim and J. Lim, "Thermographic detection of surface crack," Fall conference Proc. of Korean Society for Nondestructive Testing, pp. 241-246 (2011)

피인용 문헌

  1. Prediction of the Effect of Defect Parameters on the Thermal Contrast Evolution during Flash Thermography by Finite Element Method vol.34, pp.1, 2014, https://doi.org/10.7779/JKSNT.2014.34.1.10