Abstract
Since the modem reinforced soil wall technology was introduced in domestic civil engineering society in the year 1980, the reinforced soil walls have been extensively used because these technologies have advantages such as economical efficiency, graceful appearance, and easy construction. This paper describes the application of reinforced soil wall, design criteria, and construction problems. Many cases of troubles, which include a severe deformation of facing, cracks of facing block, overall sliding failure and so on, have been reported. Inappropriate design and construction management mainly induce these problems. The technological level of design and quantity control for reinforced soil wall is not sufficiently supported to cope with the growth quantity of reinforced soil wall construction market and the increasing number of construction companies. The unified standard design and construction criteria of reinforced soil wall should be established with the detail consideration of overall performance and stability. The quality control of design and construction, and cost of construction must be seriously executed to construct a high quality of reinforced soil wall.
1980년 국내에 현대적인 보강토 옹벽이 도입된 이후 최근에는 경제성, 수려한 외관, 시공성 등의 장점으로 인해 보강토 옹벽이 기존의 콘크리트 옹벽을 급속히 대체하고 있다. 이에 본 논문에서는 국내 보강토 옹벽 시장의 현황 및 문제점을 조사, 분석하였다. 보강토 옹벽 시장의 확장과 더불어 벽체변형, 전면블록의 균열, 전반활동 등과 같은 피해사례가 증가하고 있으며, 이러한 문제는 주로 부적절한 설계와 시공관리에 기인한다. 또한 보강토 옹벽 시장의 급속한 성장성에 비해 설계 및 품질관리 등에서의 기술적인 수준이 높지 않은 것으로 파악되었다. 따라서 보강토 옹벽의 설계 및 시공에 대한 통일된 기준이 시급히 마련되어야 한다. 또한 보강토 옹벽의 품질을 향상시키기 위해서는, 설계, 시공 및 경제성에 대한 보다 세심한 검토가 요구된다.