References
- E. Tatrai, Z. Kovacikova, A. Hudak, Z. Adamis and G. Ungvary, "Comparative in Vitro Toxicity of Cadmium and Lead on Redox Cycling in Type II Pneumocytes", J. Appl. Toxicol , 21, 479 (2001). https://doi.org/10.1002/jat.784
- P. Suciu, M. Vega, and L. Roman, "Determination of Cadmium by Differential Pulse Adsorptive Stripping Voltammetry", J. Pharmaceut Biomed, 3, 99 (2000).
- G. Centineo, E. B. Gonzalez and A. S. Medel, "Multielemental Speciation Analysis of Organometallic Compounds of Mercury, Lead and Tin in Natural Water Samples by Headspace-solid Phase Microextraction Followed by Gas Chrmatography-mass Spectrometry", j. Chromatogr A, 1034, 191 (2004). https://doi.org/10.1016/j.chroma.2004.01.051
- L. Liang, G. B. Jiang, J. F. Liu, and J. T. Hu, "Speciation Analysis of Mercury in Seafood by using High-performance Liquid Chromatography On-line Coupled with Cold-vapor Atomic Fluorescence Spectrometry Via a Post Column Microwave Digestion", Anal Chim Acta, 477, 131 (2003). https://doi.org/10.1016/S0003-2670(02)01412-5
- C. F. Harrington, S. A. Merson, and T. M. D' Silva, "Method to Reduce the Memory Effect of Mercury in the Analysis of Fish Tissue using Inductively Coupled Plasma Mass Spectrometry", Anal Chim Acta, 505, 247 (2004). https://doi.org/10.1016/j.aca.2003.10.046
- S. Y. Ly, J. I. Chae, Y. S. Jung, W. W. Jung, H. J. Lee, and S. H. Lee, "Electrochemical Detection of Ascorbic Acid (vitamin C) using a Glassy Carbon Electrode", Nahrung/Food, 48, 201 (2004). https://doi.org/10.1002/food.200300394
- R. D. Riso, M. Waeles, P. Monbet, and C. J. Chaumery, "Measurements of Trace Concentrations of Mercury in Sea Water by Stripping Chronopotentiometry with Gold Disk Electrode: Influence of Copper", Anal Chim Acta, 410, 97 (2000). https://doi.org/10.1016/S0003-2670(99)00893-4
- M. R. G. Rubio, M. B.A. Fontes, Z. M. d. Rocha, E. M. Richter, and L. Angnes," LTCC Manifold for Heavy Metal Detection System in Biomedical and Environmental Fluids", Sensor Actuat B-Chem 103, 468 (2004).
- K. Wu, S. Hu, J. Fei, and W. Bai," Mercury-free Simultaneous Determination of Cadmium and Lead at a Glassy Carbon Electrode Modified with Multi-wall Carbon Nanotubes", Analy Chim Acta. 489, 215 (2003). https://doi.org/10.1016/S0003-2670(03)00718-9
- S. B. Hocevar, J. Wang, R. P. Deo, and B. Ogorevc, ''Potentiometric Stripping Analysis at Bismuth-Film Electrode", Electroanal, 14, 112 (2002). https://doi.org/10.1002/1521-4109(200201)14:2<112::AID-ELAN112>3.0.CO;2-5
- K. Fanta and B. S. Chandravanshi, "Differential Pulse Anodic Stripping Voltammetric Determination of Cadmium(II) with N-p-chlorophenylcinnamohydroxamic Acid Modified Carbon Paste Electrode", Electroanal 13, 484 (2001). https://doi.org/10.1002/1521-4109(200104)13:6<484::AID-ELAN484>3.0.CO;2-M
- T. H. Degefa, B. S. Chandravanshi, and H. Alemu, "Differential Pulse Anodic Stripping Voltammetric Determination of Lead(II) with N-p-Chlorophenylcinnamohydroxamic Acid Modifid Carbon Paste Electrode", Electroanal, 17, 1305 (1999).
- H. Karadeniz, B. Gulmez, F. Sahinci, A. Erdem, G. I. Kaya, N. Unver, B. Kivcak, and M. Ozsoz, "Disposable Electrochemical Biosensor for the Detection of The Interaction Between DNA and Lycorine Based on Guanine and Adenine Signals", J. Pharmaceut Biomed, 2003, 33, 295 (2003). https://doi.org/10.1016/S0731-7085(03)00283-8