DOI QR코드

DOI QR Code

Leakage Reduction through Establishment of Block System in Jeju City

제주시 상수도 관망 블록시스템 구축을 통한 누수 저감

  • Published : 2012.10.15

Abstract

Leakage in water supply system can cause water resources loss in addition to the water quality degradation. In this research, leakage reduction after establishment of a block system in the area with leakage rate of 69.0 % was investigated using EPANET simulation. The average water pressure for the research area was $5.17kgf/cm^2$ which was relatively high, and several sites were deviated from recommended water pressure ranges(i.e., 1.5 ~ $7.1kgf/cm^2$). However, the average water pressure in the area was reduced to 3.81 and $3.49kgf/cm^2$ after the introduction of block system with a water pressure relief valve(PRV) setting of 3.0 and $2.5kgf/cm^2$, respectively. Under the installation of a PRV with regulating pressure of $2.5kgf/cm^2$, the predicted leakage was reduced from $4,420.3m^3/d$ to $3,028.1m^3/d$, which was equivalent to the leakage reduction from 31.0 % to 23.5 %.

Keywords

References

  1. 구자용, 이현동, 홍인식, 김정구, 김경필 (2007) 누수 장지 및 저감 기술의 적용사례, 대한환경공학회지, 29(12), pp. 1-8.
  2. 김진근, 이송희, 김재원 (2010) 급속여과공정에서 여과수질 저하원인 및 개선방안, 상하수도학회지, 24(3), pp. 333-339.
  3. 이진효, 김신걸, 정신호, 구자용 (2006) PRVs를 이용한 누수량 저감효과 분석, 한국물환경학회.대한상하수도학회 춘계학술발표회 논문집, pp. 731-741.
  4. 제주특별 자치도 (2008) 제주특별자치도 수도정비기본계획.
  5. 환경부 (2010) 상수도시설기준.
  6. 환경부 (2011a) 먹는물 수질관리 지침.
  7. 환경부 (2011b) 2010 상수도 통계연보.
  8. 환경부, 수처리선진화사업단, 한국수자원공사 (2010) 상수관망 최적관리 기술안내서.
  9. 차준호 (2012) 제주시 도련지역 상수도 블록시스템 구축에 따른 누수저감 효과 분석, 제주대학교 건설환경공학과 석사학위논문.
  10. EPA 홈페이지 (2012) http://www.epa.gov/nrmrl/wswrd/dw/epanet.html.

Cited by

  1. Hydraulic Characteristics of Leakage for the Monitoring of Water Distribution System vol.16, pp.3, 2016, https://doi.org/10.9798/KOSHAM.2016.16.3.235