Effect of Opaque on Resin Bonding to Calcium Phosphate Crystalline Ceramic

  • Kim, Do Hoon (Department of Dentistry, Graduate School, Kyungpook National University) ;
  • Hur, Hoon (Seldent Co.) ;
  • Kim, Kyo-Han (Department of Dental Biomaterials, School of Dentistry) ;
  • Kwon, Tae-Yub (and Institute for Biomaterials Research & Development)
  • Published : 2012.09.01

Abstract

The purpose of this study was to examine the effect of opaque on resin bonding to calcium phosphate crystalline ceramics (CPCC). Disk-shaped specimens were made from the calcium phosphate crystalline ceramics (Crys-Cera). All specimens were ground with 800-grit abrasive paper, cleaned and finally air-dried. Control group (CT group) didn't undergo any treatment. Coating of one layer opaque treatment (OP1) and two layer opaque treatment (OP2) was performed. Sandblasting (SB group) was done with alumina powders. After that resin cements (Duo-Link, Panavia F 2.0, Maxcem) were applied to the surface using a bonding clamp and light-cured. All the specimens were stored in distilled water at $37^{\circ}C$. After 24 h storage in water, each specimen was fixed to a jig and loaded at a crosshead speed of 1 mm/min until failure in a universal testing machine. Surface morphology of the treated specimens was observed and surface roughness values (Ra) were measured. The data were analyzed using a one-way ANOVA with Tukey's post hoc test at a significance level of 0.05. Coating of the opaque on CPCC surface substantially increased surface roughness of CPCC surface. Two layer coating of the opaque group substantially increased surface roughness, when compared to one layer coating of the opaque group. Mechanical roughening using alumina particle increased surface roughness similar to one layer coating of the opaque group. In shear bond strength tests with specimens bonded with Duolink and Panavia F 2.0, OP2 group showed the highest shear bond strength. In test using Maxcem, SB group showed the highest shear bond strength. In failure pattern, CT and SB groups showed all adhesive failure, and OP1 and OP2 groups showed adhesive failure and mixed failure.

Keywords

References

  1. S. F. Rosenstiel, S. S. Porter, and W. M. Johnston, "Colour measurements of all ceramic crown systems," J. Oral. Rehabil., 16, 491-501 (1989). https://doi.org/10.1111/j.1365-2842.1989.tb01370.x
  2. H. Dumfahrt and H. Schaffer, "Porcelain laminate veneers. A retrospective evaluation after 1 to 10 years of service: Part II-clinical results," Iint. J. Prosthodont., 13, 9-18 (2000).
  3. M. J. Friedman, "Ask the experts: porcelain veneers," J. Esthet. Restor. Dent., 13, 86-87 (2001). https://doi.org/10.1111/j.1708-8240.2001.tb00430.x
  4. M. Fuzzi and G. Rappelli, "Ceramic inlays: clinical assessment and survival rate," J. Adhesive. Dent., 1, 71-79 (1999).
  5. M. B. Blatz, "Long-term clinical success of all-ceramic posterior restorations," Quintessence. Int., 33, 415-426 (2002).
  6. O. El-Mowafy and M. H. Rubo MH, "Resin-bonded fixed partial dentures-a literature review with presentation of a novel approach," Int. J. Prosthodont., 13, 460-467 (2000).
  7. G. Corrente, L. Vergnano, S. Re, D. Cardaropoli, and R. Abundo, "Resin-bonded fixed partial dentures and splints in periodontally compromised patients: a 10-year follow-up," Int. J. Periodontics. Restorative. Dent., 20, 628-636 (2000).
  8. K. A. Malament and S. S. Socransky, "Survival of Dicor glassceramic dental restorations over 14 years. Part II: effect of thickness of Dicor material and design of tooth preparation," J. Prosthet. Dent., 81, 662-667 (1999). https://doi.org/10.1016/S0022-3913(99)70104-6
  9. J. A. Sorensen JA, S. K. Kang, and S. P. Avera, "Porcelain-composite interface microleakage with various porcelain surface treatments," Dent. Mat., 7, 18-23 (1991). https://doi.org/10.1016/0109-5641(91)90020-Y
  10. O. Mowafy, "The use of resin cements in restorative dentistry to overcome retention problems," J. Can. Dent. Assoc., 67, 97-102 (2001).
  11. H. Kitazaki, H. Takahashi, S. Hasegawa, F. Nishimura, "Effect of amount of grinding on flexural strength of dental ceramics," J. Med. Dent. Sci., 48, 7-13 (2001).
  12. Y. Abe, T. Arahori, A. Naruse, "Crystallization of Ca(PO3)2 glass below the glass transition temperature." J. Am. Ceram. Soc., 59, 487-490 (1976). https://doi.org/10.1111/j.1151-2916.1976.tb09414.x
  13. R. D. Ray RD and A. A. Ward, "A preliminary report on studies of basic alcium phosphate in bone replacement," in Surgical Forum, American College of Surgeons, WB Saunders Co, Philadelphia, 1952, pp. 429-434.
  14. P. W. Brown, "A new calcium phosphate, water setting cement," in Cements Research Progress, American Ceramic Society, Westerville, Ohio, 1987, pp. 352-379.
  15. L. C. Chow, "Next generation calcium phosphate-based biomaterials," Dent. Mater. J., 28, 1-10 (2009). https://doi.org/10.4012/dmj.28.1
  16. K. Suese, S. Yamashita, S. Yasuda, M. Toda, and T. Kawazoe, "The bonding strength of adhesive resin cement and calcuim phosphate crystalline ceramics - The effect of opaque material," J. Esthet. Dent., 6, 12-18 (1993).