Effect of Kinematic Motion on The Coefficients of Friction of UHMWPEs for Total Joint Replacements

기구학적 운동이 인공관절 베어링용 초고분자량 폴리에틸렌 재료들의 마찰 특성에 미치는 영향 평가

  • Kim, C.Y. (Department of Mechanical Engineering, Bioengineering Research Center, Sejong University) ;
  • Kim, H. (Department of Mechanical Engineering, Bioengineering Research Center, Sejong University) ;
  • Kim, D.W. (Department of Mechanical Engineering, Bioengineering Research Center, Sejong University) ;
  • Lee, K.Y. (Department of Mechanical Engineering, Bioengineering Research Center, Sejong University)
  • 김충연 (세종대학교 기계공학과/의공학연구소) ;
  • 김환 (세종대학교 기계공학과/의공학연구소) ;
  • 김동욱 (세종대학교 기계공학과/의공학연구소) ;
  • 이권용 (세종대학교 기계공학과/의공학연구소)
  • Published : 2012.03.01

Abstract

Total joint replacement (TJR) has been used for treating joint diseases since 1960s to restore function and mobility without pain that result of osteoarthritis, rheumatoid arthritis and femoral neck fractures. Co-Cr alloy and ultra-high molecular polyethylene (UHMWPE) are widely used for articulating bearing component with its biocompatibility and excellent mechanical properties. In this study, we evaluated frictional characteristics of three kinds of the most representative UHMWPEs against Co-Cr alloy under a contact pressure of 5MPa in two different kinematic motions with a Pin-on-Disk type tribo-tester. Conventional gamma-irradiated UHMWPE (GIPE) specimens were machined from ramextruded Chirulen$^{(R)}$1020 rod and then gamma-irradiated with a dose of 4.0Mrad. Remelted highly cross-linked UHMWPE (RXLPE) were machined from hip liner of Zimmer$^{TM}$ product. Sequentially irradiated and annealed highly cross-linked UHMWPE (AXLPE) were machined from knee liner of Striker$^{TM}$ product. To evaluate the effect of kinematic motion on the coefficients of friction (COF) between UHMWPE cylindrical pin specimens and orthopaedic grade Co-Cr alloy disk specimens, a repeat passed rotational motion and a linear reciprocal sliding motion tests were conducted and their COF were compared. As a result, the mean COF of all kinds of UHMWPEs in a reciprocal motion were significantly higher than in a rotational motion. Mean COF of GIPE were higher than two kinds of highly crosslinked UHMWPEs in both kinematic motions. Consequently, based on this comparative analyses in this study, kinematic motion gave a significant influence on the frictional property of tested all kinds of UHMWPEs.

Keywords

References

  1. K. S. K. Karuppiah, A. L. Bruck, S. Sundararajan, J. Wang, Z. Lin, Z. H. Xu, X. Li, "Friction and wear behavior of ultra-high molecular weight polyethylene as a function of polymer crystallinity," Acta Biomaterialia, 4, 1401-1410 (2008).
  2. J. Fisher, J. L. Tipper, M. H. Stone, C. Davies, J. Bolton, C. Hardaker, G. Berry, "Wear of surface engineered metal-on-metal hip prostheses," Journal of Materials Science: Materials in Medicine, 15, 225-235 (2004).
  3. S. P. Ho, R. W. Carpick, T. Boland, M. LaBerge, "Nanotribology of CoCr-UHMWPE TJR prosthesis using atomic force microscopy," Wear, 253, 1145-1155 (2002).
  4. S. Alhassan, T. Goswami, "Wear rate model for UHMWPE in total joint applications," Wear, 265, 8-13 (2008).
  5. S. Wang, S. Ge, "The mechanical property and tribological behavior of UHMWPE: Effect of molding pressure," Wear, 263, 949-956 (2007).
  6. S. M. Kurtz, UHMWPE BIOMATERIALS HANDBOOK, Second Edition, Academic Press, Elsevier, 2009.
  7. S. M. Kurtz, O. K. Muratoglu, M. Evans, A. A. Edidin, "Advances in the proceccing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joing arthropathy," Biomaterials, 20, 1659-1688 (1999).
  8. A. S. Shanbhag, H. O. Bailey, D. S. Hwang, C. W. Cha, N. G. Eror and H. E. Rubash, "Quantitative Analysis of Ultrahigh Molecular Weight Polyethylene (UHMWPE) Wear Debris Associated with Total Knee Replacements ; WEAR DEBRIS IN TOTAL KNEE REPLACEMENTS," John Wiley & Sons., 100-110 (2000).
  9. G. Shirong, W. Qingliang, Z. Dekun, Z. Hua, X. Dangsheng, H. Chuanhui, H. Xiaolong, "Friction and wear behavior of nitrogen ion implanted UHMWPE against $ZrO_2$ ceramic," Wear, 255, 1069-1075 (2003).
  10. W. H. Harris, "The problem is osteolysis," Clin. Orthop. Relat. Res., 311, 46-53 (1995).
  11. H. C. Amstutz, P. Campbell, N. kossovky, I. C. Clarke, "Mechanism and clinical significance of wear debris-induced osteolysis," Clin. Orthop. Relat. Res., 276, 7-18 (1992).
  12. S. R. Goldring, C. R. Clark and T. M Wright, "The problem in total joint arthroplasty : Aseptic loosening," The Journal of Bone & Joint Surgery, 75, 799-801 (1993).
  13. V. Banchet, V. Fridrici, J. C. Abry and Ph. Kapsa, "Wear and friction characterization of materials for hip prosthesis," Wear, 263, 1066-1071 (2007).
  14. K. Y. Lee, "Effect of kinematic Motions and Contact Configurations on the Wear of UHMWPE," Journal of the KSTLE, 18(2), 143-146 (2002).
  15. C. R. Bragdon, D. O. O'Connor, J. D. Lowenstein, M. Jasty, W. D. Syniuta, "The importance of multi directional motion on the wear of polyethylene," Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 210, 157-165 (1996).
  16. A. C. Dunn, J. G. Steffens, D. L. Burris, S. A. Banks, W. G. Sawyer, "Spatial geometric effects on the friction coefficients of UHMWPe," Wear, 264, 648-653 (2008).
  17. A. Wang, "A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding," Wear, 248, 38-47 (2001).