Abstract
This research is to propose the reinforcing method and design code for the lateral behaviors of the abutment displacement induced from the rainfall infiltration on high landfill slope. First, to make the proper numerical analysis, in-situ soil (weathered granite soil) was taken, and the variance of strength parameters according to water content variance was examined by undrained direct shear test, furthermore, other soil parameters were calculated from the standard penetration test such as elastic modulus and Poisson's ratio etc,. Those parameters were used to calculate the lateral behavior of abutment by finite element method and the member force of pile in high landfill slope according to rainfall infiltration . From the results, the shoe displacement on abutment was calculated as 8.98cm, which is 3 times bigger than the allowable displacement, 3cm. To reinforce it, several reinforcing methods were selected and analyzed such as reinforced retaining wall, soil surcharge, pile reinforcing (5m enlargement, 3-line arrangement, 5m enlargement and 3-line arrangement). In case of 5m enlarged and 3-line arrangement piles, the lateral behavior of shoe showed lower value(2.26 cm) than allowable displacement.
본 연구에서는 고성토사면 위에 시공된 교대가 강우 침투로 측방유동이 발생되었을 경우 이로 인한 교대의 상대변위를 파악하고 적절한 보강대책 및 설계기준을 제안하고자 한다. 먼저 성토사면의 정확한 수치해석을 위해 현장의 성토재인 화강풍화토를 채취하여 비배수 직접전단시험을 통해 함수비(포화도)변화에 따른 강도정수의 변화를 파악하고 표준관입시험 결과를 토대로 탄성계수와 포아송비 등의 지반정수를 산정하였다. 이후 유한요소법을 이용하여 강우 시 교대 교좌부의 측방유동, 말뚝기초의 부재력을 산정하였다. 산정 결과, 교대 교좌부의 측방변위는 8.98cm로 허용변위량 3.0cm보다 약 3배 정도 크게 산정되었다. 측방유동의 보강대책으로 보강토옹벽, 압성토, 말뚝 기초 자체보강(길이 5m 연장보강, 3열 보강, 3열 5m 연장보강) 등에 대해 검토하였다. 그 결과, 말뚝기초를 보강 (3열 5m 연장보강) 하였을 경우 측방유동으로 인한 교대 교좌부의 상대변위는 2.26cm로 허용변위량보다 적었다.