The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography

유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화

  • Lee, Da-Young (Department of Nuclear Medicine in Yonsei University Health System) ;
  • Nam-Koong, Hyuk (Department of Nuclear Medicine in Yonsei University Health System) ;
  • Cho, Seok-Won (Department of Nuclear Medicine in Yonsei University Health System) ;
  • Oh, Shin-Hyun (Department of Nuclear Medicine in Yonsei University Health System) ;
  • Im, Han-Sang (Department of Nuclear Medicine in Yonsei University Health System) ;
  • Kim, Jae-Sam (Department of Nuclear Medicine in Yonsei University Health System) ;
  • Lee, Chang-Ho (Department of Nuclear Medicine in Yonsei University Health System) ;
  • Park, Hoon-Hee (Department of Radiology in Shin-Gu University at Seongnam)
  • 이다영 (연세의료원 세브란스병원 핵의학과) ;
  • 남궁혁 (연세의료원 세브란스병원 핵의학과) ;
  • 조석원 (연세의료원 세브란스병원 핵의학과) ;
  • 오신현 (연세의료원 세브란스병원 핵의학과) ;
  • 임한상 (연세의료원 세브란스병원 핵의학과) ;
  • 김재삼 (연세의료원 세브란스병원 핵의학과) ;
  • 이창호 (연세의료원 세브란스병원 핵의학과) ;
  • 박훈희 (신구대학교 방사선과)
  • Received : 2012.06.25
  • Accepted : 2012.10.02
  • Published : 2012.10.27

Abstract

Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

유방암 환자의 감시림프절 생검을 위하여 현재 방사성동위원소와 blue dye를 이용한 감시림프절 매핑(Mapping)이 선행되고 있다. 현재 모든 환자에 대하여 일괄적인 검사방법이 적용되므로 환자의 유방의 크기나 비만도와 같은 특성이 고려되지 않아 림프절의 흐름이 느린 환자의 경우, 림프절을 충분히 형성하지 못한 채 검사가 종료되는 경우가 종종 발생한다. 본 연구에서는 환자의 신체적 특성인 체질량지수와 유방의 크기에 따른 림프액의 속도차이를 관찰하였다. 이를 통해 방사성동위원소를 이용한 유방의 감시림프절 신티그래피 에서 환자의 특성을 고려한 최적의 검사시간을 도출하는데 목적을 두었다. 본 연구는 2011년 10월부터 2011년 12월까지 수술직전 유방의 감시림프절 신티그래피를 시행한 100명(여성 100명, 평균연령 $50.34{\pm}10.26$)를 대상으로 하였다. 장비는 감마카메라 Forte (Philips Medical Systems, Nederland B.V.)를 사용하였으며, 방사성의약품은 $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml를 피내주사하였다. 먼저 80명의 환자를 대상으로 기존의 5분 검사방법대신 충분히 림프절을 형성할 때까지 시간의 제한 없이 영상을 획득하였다. 이를 통해 환자의 유방크기와 체질량지수 별 그룹을 나누어 평균 검사시간을 구하였다. 이 결과를 바탕으로 검사시간을 변화시킨 변형 유방 림프신티그래피를 20명의 환자에게 시행하여 유용성을 확인하였다. 80명의 대상 중 유방의 크기에 따른 평균 검사시간은 A그룹 2.48분, B그룹 7.69분, C그룹 10.43분이었다. 80명의 대상 중 체질량지수에 따른 평균 검사시간은 저 체중 1.35분, 표준 2.56분, 과 체중 5.62분, 비만 15분이었다. 앞서 얻어진 정보를 바탕으로 각 그룹별 적절한 검사시간을 적용하여 검사를 시행하였다. 결과는 20명 중 성공평가를 받은 경우는 17회 실패평가를 받은 경우는 3회로 총 85% 성공률을 나타내었다. 유방의 크기와 체질량지수에 따른 총 검사 시간은 체질량지수가 높을수록, 유방의 크기가 클수록 증가하였으며, 얻어진 정보를 바탕으로 기존 검사방법에서 검사시간만을 변화시킨 변형 유방 림프신티그래피를 적용하였을 때 대부분의 경우 검사시간 내 림프절을 형성할 수 있었다. 이를 통해 모든 환자에게 일괄적으로 적용하던 검사방법보다 개인의 신체적 특성을 고려한 적절한 검사시간을 각각 다르게 적용하였을 때 검사에서 높은 성공률을 보임을 알 수 있었다.

Keywords