DOI QR코드

DOI QR Code

A Study on Estimation of Coverage Area Per Elevator for High-rise Office Buildings

초고층 업무시설의 엘리베이터 대당 서비스면적 산출에 관한 연구

  • 최재필 (서울대학교 건축학과) ;
  • 강준경 (서울대학교 대학원 건축학과) ;
  • 김도영 (서울대학교 대학원 건축학과) ;
  • 정은석 (서울대학교 대학원 건축학과) ;
  • 이정원 (충남대학교 건축학과)
  • Received : 2012.07.31
  • Published : 2012.10.25

Abstract

Elevator planning for high-rise office buildings is one of the most significant planning elements considering that it directly affects users' convenience and area efficiency. When establishing elevator plans for high-rise office buildings, decisions for vertical zoning should be made. Determining the amount of coverage area per elevator is relevant to deciding the number of floors per zone. Therefore, the purpose of this study is to determine the range of area that one elevator can cover so that elevator plan can be established during the initial planning stage for high rise office buildings. This research is based on quantitative methods using proven calculation and the result can be used as a guideline for elevator planning.

Keywords

Acknowledgement

Supported by : 국토해양부

References

  1. K.J. Butcher, J. Wilson, CIBSE Guide D, Chartered Institution of Building Services Engineers in London, 1993
  2. George R. Strakosch, The Vertical Transportation Handbook, Wiley, 1988
  3. 조지 스트라코시 저, 한국엘리베이터협회 번역, 엘리베이터 및 에스컬레이터, 한국엘리베이터 협회, 1993
  4. 건설교통부, "초대형 고층 건물의 건축계획, 구조, 설비 및 시공기술 개발", 2001
  5. 최재필, 이정원, 강준경, 김도영, 정은석, 초고층 업무시설의 엘리베이터 최적 수직조닝방식 도출에 관한 연구, 대한건축학회논문집 계획계, 27(12), 181-188
  6. Ove Arup & Partners Ltd, Parc1: Detailed Design-Vertical Transportation Strategy Report