Acknowledgement
Supported by : 한국연구재단
References
- Pall A S and Marsh C.: Seismic Response of Friction Damped Braced Frames, Journal of Structural Division, ASCE, Vol.108, No.ST6, pp.1313-1323, 1982
- Gregorian, C.E. et al.: Slotted Bolted Connection Energy Dissipaters, Earthquake Spectra, Vol.9, FD-3, pp.491-504, 1993
- Soon T T and Spencer Jr B F: Supplemental Energy Dissipation:State-of-the-Art and State-of-the-Practice, Engineering Structure, Vol.24, FD-3, pp.243-259, 2002 https://doi.org/10.1016/S0141-0296(01)00092-X
- ATC, Seismic evaluation and retrofit of concrete buildings, ATC-40 Report, Applied Technology Council, Redwood City, California, 1996.
- FEMA, NEHRP Guidelines for the seismic rehabilitation of buildings, Report No. FEMA-273, Federal Emergency Management Agency, Washington, D.C., 1997.
- Mualla, I.H., Belev, B., Performance of steel frames with a new friction damper device under earthquake excitation, Engineering Structures, Vol. 24, 2002, pp.365-371. https://doi.org/10.1016/S0141-0296(01)00102-X
- Pall AS, Marsh C. Response of friction damped braced frames. J Struct Div ASCE 1982 108: 1313- 1323.
- Aiken I, Kelly S. Earthquake simulator testing and analytical studies of two energy absorbing systems for multi-storey structures. Report No. UCB/EERC-90/03, EERC, Berkeley, 1990.
- Constantinou MC, Reinhorn AM, Mokha AS, Watson R. Displacement control device for base isolated bridges. Earthquake Spectra, EERI 1991, 7(2):179-200. https://doi.org/10.1193/1.1585625
- Fitzgerald TF, Anagnos T, Goodson M, Zsutty T. Slotted bolted connections in a seismic design of concentrically braced connections. Earthquake Spectra, EERI 1989;5(2):383-091. https://doi.org/10.1193/1.1585528
- Grigorian CE, Popov EP., Slotted bolted connection energy dissipaters. Earthquake Spectra, EERI 1993;9(3):491-504. https://doi.org/10.1193/1.1585726
- Nims DK, Richter PJ, Bachman RE. The use of the energy dissipation restraint for seismic hazard mitigation. Earthquake Spectra, EERI 1993, 9(3):467- 487. https://doi.org/10.1193/1.1585725
- Mualla, I.H., Belev, B., Performance of steel frames with a new friction damper device under earthquake excitation, Engineering Structures, Vol. 24, 2002, pp.365-371. https://doi.org/10.1016/S0141-0296(01)00102-X
- 若林信宏,大亦絢一郎, 齋藤宏和 : 漸硬形抵抗力特性を有する 摩擦ダンパの研究, 日本機械學會論文集 (C編), Vol.73, No.732, pp.15-22, 2007.8
- 신용우, 이상권, 원형 마찰 감쇠기 특성의 심험식 개발, 한국소음진동공학회논문집, 제21권 제6호, pp. 491-498, 2011
- 노지은, 이상현, 건축구조물의 내진보강을 위한 회전형 마찰 감쇠기의 성능실험, 대한건축학회논문집 구조계, 제27권, 제 12호(통권278호), 2011. 12
- 寺井雅和, 佐藤孝典, 吉岡智和, 南宏一 : アルミを挟んだ風地 震ハイブリッド摩擦ダンパー に關 する研究, 日本建築學會構造系論文集, No.633, pp.2037-2044, 2008.11
- WU Bin, ZHANG Ji-gang and OU Jin-ping: The Analysis and Comparison of Seismic Performance of Structures with Three Types of Dampers, World Earthquake Engineering, Vol.20, FD-1, pp.21-26, 2004
- 深澤協三,長谷川豊,棚橋禎之,三好正和ほか : 摩擦ダンパー CFDを用いた戸建て住宅制震構法の開発, 日本建築學會技術 報告集, Vol.13, FD-26, pp.551-556, 2007.12
- 笠口井和彦, 和田章, 坂田弘安ほか : 變位依存ダンパー をもつ 木質架構の振動台実験, 日本建築學會構造系論文集, No.594, pp.101-110, 2005.8
- 横内基, 北嶋圭 二, 中西三和, 安達洋, 青山博之 : 摩擦ダン パー を用いて制震補強された既存RC造建物の地震応答性状に 關 する研究, 日本建築學會構造系論文集, No . 628, pp.947-955, 2008.6
- Ou Jinping and Yang Yang: Piezoelectric-T Shape Variable Friction Damper and Its Performance Tests and Analysis, Earthquake Engineering and Engineering Vibration(China), Vol.23, No.4, pp.171-177, 2003
- Wang Wei and Li Qingxiang: An Experimental Study On Electromagnet Friction Energy Dissipation Device in Passive Structureal Control, China Civil Engineering Journal, Vol.37, FD-12, pp.17-22, 2004
- 佐野剛志, 鈴井康正, 日野泰成, 高橋泰彦 : 高力ボハルト摩擦接合滑りダンパー (ブレー キダンパー ) の開発, 大林組技術研究所報, No.62, pp.13-20, 2000 B-2, pp.539-540, 2008.9
- 張蓬勃, 崔宰赫, 藤永隆, 孫玉平 : 耐力可変摩擦ダンパー 基本 性能 に關する研究, 鋼構I造論文集, Vol.16, No.63, pp.79-86, 2009.9
- 張蓬勃, 孫玉平, 藤永隆, 崔宰赫 : 肌隙を有するせん断型摩擦 ダンパー のすべり耐力に關する研究, 鋼構造論文集, Vol.16, No.64, pp.41-48, 2009.12
- 佐野剛志, 鈴井康正, 日野泰成, 高橋泰彦 : 高力ボ{ルト摩擦 接合滑りダンパー (ブレー キダンパー) の開発(その大林組 技術研 究所報, No.70, pp.1-6, 2006
- JMES, Document for promotion of seismic upgrading of the existing school buildings and facilities, Document, Ministry of Education and Science, Japan, Mar.,2005
- Pengbo ZHANG, Kosuke MUNAMA,Ryoichi TAKISHIT A,Jae-hyouk CHOI, Kenichi OHI, Sub- structure PseudodNnamic Test on linked Structure System with Low Niel d Point Steel Damper, Journal of Construction Steel, Vol.14, No.363-370, Nov., 2006
- Kouichi IWANAMI,Kouhei SUZUKI and Kazuto SETO, Vibration Control Method of Parallel Structures Connected to Each Other With Damper and Spring, Vol.59, No.566, 2975-2980, 1993
- Mitsuru KAGENAMA,Nuzuru NASUI and Kazuto SATO, THE PRINCIPAL SOLUTIONS OF CONNECTING SPRIN G AND DAMPER FOR OPTIMUM VIBRATION CONTR OL UNDER SEVERAL CRITERIA. J.struct.Constr.Eng.,AI J, No.529, 97-104, Mar.,2000
- C.E.Grigorian,T.S.Nang,and E.P.Popov,M.EERI, Slotted Bolted Connection EnergN Dissipaters, Earthquake Spectra,Vol.9,No.3,1993
- Tomokazu NOSHIOKA, STUDIES OF BOLTED FRICTIO NAL-SLIPPAGE CONNECTIOE Part1 Experiments of fric tional-slippage connection using aluminum alloy sliding pl ates, J.struct.Constr.Eng.,AIJ,No.573,217-222,Nov.,2003
- Garcia D.L, and Soong T.T, Effciency of a simple approach to damper allocation in MDOF structures, Journal of Structures Control, Vol.9,No1, pp.19-30, 2002 https://doi.org/10.1002/stc.3
- Chopra A.K, Dynamics of Structures TheorN and Applicat ions to Earthquake Engineering, Prentice Hall, 1995