Abstract
In this study, $CO_2$ adsorbent was developed for removing low concentration of $CO_2$ in multiple-use facilities. The efficiency of the adsorbent which was improved selective $CO_2$ adsorption capabilities was evaluated. The pellet type adsorbent was modified from a commercial zeolite with mixing LiOH, binder, additives, and $H_2O$. Column tests showed over 90 % of $CO_2$ was adsorbed within 400min. Chamber tests including batch and continuous types were performed for evaluating the adsorbent module. By batch tests, it was evaluated that about 92% of $CO_2$ was removed within 30 min. By continuous tests, 70% of $CO_2$ was removed within 30 min. It was analyzed that over 2,500 ppm of $CO_2$ was continuously removed as shown chamber tests. The reproducibility tests repeatedly performed for 15 days shows that over 1,000 ppm of $CO_2$ was continuously removed. Adsorption capacity of the developed adsorbent was 5.0mmol $CO_2/g$ adsorbent which was analyzed by TGA. It was estimated that the modified adsorbent was applicable to low $CO_2$ concentration and low temperature of indoor environment.
본 논문은 다양한 시설내에 적은 농도의 $CO_2$ 제거를 위한 선택적 $CO_2$ 흡수능력을 향상시킨 흡착제의 효율평가에 관한 것이다. 직경 4mm의 구형 흡착제는 시판용 제올라이트에 첨가제, 물, 바인더, LiOH를 섞어 제조하였다. 칼럼테스트에서 400분 이내에 90% 이상의 $CO_2$흡착효율을 나타내었고, 흡착필터모듈 흡착능력을 평가하기 위해 회분식과 연속식타입의 챔버테스트가 시행되었다. 회분식테스트에서 30분 이내에 약 92%의 $CO_2$가 제거되는 것을 확인하였다. 연속식테스트에서 30분 이내 70%의 $CO_2$가 제거효율을 보였으며, 2,500ppm 이상의 $CO_2$가 제거되는 것을 확인하였다. 재현성테스트를 수차례 수행한 결과 15일동안 1,000ppm 이상의 $CO_2$가 연속적으로 제거됨을 보였다. TGA 분석법을 이용한 흡착량 분석에서 흡착제 g당 5.0mmol의 $CO_2$를 흡착하는 것으로 나타났다. 본 연구에서 개발된 흡착제는 상온에서 저농도 $CO_2$ 실내환경에 적용가능한 것으로 판단된다.