Abstract

This study conducted infrared (IR) thermography tests using pipe and plate specimens with artificial wall-thinning defects to find an optimal condition for IR thermography test on the wall-thinned nuclear piping components. In the experiment halogen lamp was used to heat the specimens. The distance between the specimen and the lamp and the intensity of halogen lamp were regarded as experimental parameter. When the distance was set to 1~2 m and the lamp intensity was above 60 % of full power, a single scanning of IR thermography detected all artificial wall-thinning defects, whose minimum dimension was $2{\Theta}=90^{\circ}$, d/t=0.5, and $L/D_o=0.25$, within the pipe of 500 mm in length. Regardless of the distance between the specimen and the lamp, the image of wall-thinning defect in IR thermography became distinctive as the intensity of halogen lamp increased. The detectability of IR thermography was similar for both plate and pipe specimens, but the optimal test condition for IR thermography depended on the type of specimen.

본 논문에서는 적외선 열화상 기법을 원전 배관에 적용하여 감육결함을 검사하기 위한 시험 조건을 파악하기 위해서, 인공 결함이 가공된 배관 시편과 평판 시편을 이용하여 적외선 열화상 시험을 수행하였다. 시험에는 할로겐램프를 사용하여 시편을 가열하였으며, 램프의 출력과 시편과 램프의 거리를 변수로 실험을 수행하였다. 시험 결과 시편과 램프의 거리가 1~2 m 이고 램프의 출력이 정격출력의 60 % 이상일 때, 적외선 열화상 기법은 1회 촬영으로 최소한 500 mm 범위 내에 존재하는 원주방향 폭이 $2{\Theta}=90^{\circ}$이고 깊이와 길이가 각각 d/t=0.5와 $L/D_o=0.25$인 배관내 인공 감육 결함들을 검출하였다. 평판 시편과 배관 시편에서 시편과 램프의 거리에 관계없이 램프 출력이 높을수록 결함에 대한 이미지가 선명하였다. 평판 시편과 배관 시편에서 적외선 열화상 방법의 결함 검출 능력은 유사하지만, 최적의 시험 조건은 시편에 따라 다르게 나타났다.

Keywords

References

  1. F. Michel, H. Reck and H. Schulz, "Experience with piping in German NPPs with respect to ageing-related aspects," Nuclear Engineering and Design, Vol. 207, pp. 307-316 (2001) https://doi.org/10.1016/S0029-5493(01)00339-9
  2. Virginia Electric and Power Co., "Surry Unit 2 Reactor Trip and Feedwater Pipe Failure Report" (1989)
  3. Korea Hydro and Nuclear Power Co., "Management Program for Thinned Pipe in NPP Secondary System," Final Report - 00NJ12 (2003)
  4. S. H. Lee, T. R. Kim, S. C. Jeon and K. M. Hwang, "Thinned pipe management program of Korean NPPs," Transaction of SMiRT-17, Paper #O04-2, Prague, Czech Republic, Aug. 17-23 (2003)
  5. IAEA, "Development of Protocols for Corrosion and Deposits Evaluation in Pipes by Radiography," IAEA-TECDOC-1445 (2005)
  6. T. Knook, M. Persoz, S. Trevin, S. Friol, M. Moutrille and L. Dejoux, "Pipe wall thinning management at Electricite de France (EDF)," E-Journal of the Advanced Maintanance, Vol. 2, pp. 1-13 (2010)
  7. A. Vageswar, K. Balasubramanian, C. V. Krishnamurthy, T. Jayakumar and B. Raj, "Periscope infrared thermography for local wall thinning in tubes," NDT&E International, Vol. 42, pp. 275-282 (2009) https://doi.org/10.1016/j.ndteint.2008.11.008
  8. G. Shen and T. Li, "Infrared thermography for high-temperature pressure pipe," Insight, Vol. 49, pp. 151-153 (2007) https://doi.org/10.1784/insi.2007.49.3.151
  9. K. Kim, H. Chang, D. Hong, C. Park, S. Na, K. Kim and H. Jung, "Defect detection of the wall thinning pipe of the nuclear power plant using infrared thermography," Journal of the Korean Society for Nondestructive Testing, Vol. 30, No. 2, pp. 85-90 (2010)
  10. K. Kim, H. Jung, C. Pack, D. Kim, D. Jung and H. Chang, "A study on measuring the temperature and revising the result when measuring the temperature of NPP pipes using infrared thermography," Journal of the Korean Society for Nondestructive Testing, Vol. 29, No. 5, pp. 421-426 (2009)
  11. J. Park, M. Choi and W. Kim, "Shearing phase lock-in infrared thermography for defects evaluation of metallic materials specimens," Journal of the Korean Society for Nondestructive Testing, Vol. 30, No. 2, pp. 91-97 (2010)
  12. M. Choi, K. Kang, J. Park, W. Kim and K. Kim, "Defect sizing and location by lock-in photo-infrared thermography," Journal of the Korean Society for Nondestructive Testing, Vol. 27, No. 4, pp. 321-327 (2007)

Cited by

  1. Application Defects Detection in the Small-Bore Pipe Using Infrared Thermography Technique vol.33, pp.1, 2013, https://doi.org/10.7779/JKSNT.2013.33.1.34