Effect of ground motion characteristics on the pure friction isolation system

  • Nanda, Radhikesh P. (Department of Civil Engineering, NIT Durgapur) ;
  • Shrikhande, Manish (Department of Earthquake Engineering, IIT Roorkee) ;
  • Agarwal, Pankaj (Department of Earthquake Engineering, IIT Roorkee)
  • 투고 : 2011.09.09
  • 심사 : 2011.12.04
  • 발행 : 2012.04.25

초록

The performance of pure friction isolation system with respect to the frequency bandwidth of excitation and the predominant frequency is investigated. A set of earthquake ground motions (artificial as well as recorded [with different combinations of magnitude-distance and local site geology]) is considered for investigating effectiveness of pure friction isolators. The results indicate the performance of pure friction base isolated system does not only depend upon coefficient of friction and mass ratio but the stick-slip behaviour depends upon the frequency content of the excitation as well. Slippage prevails if the excitation frequency lies in a suitable frequency range. This range widens with increasing mass ratio. For larger mass ratios, the sliding effect is more pronounced and the maximum acceleration response is further reduced in the neighbourhood of frequency ratio (${\omega}/{\omega}_n$) of unity. The pure friction isolation system is effective in the case of broadband excitations only and that too, in the acceleration sensitive range of periods. The pure friction system is not effective for protection against narrow band motions for which the system response is quasi-periodic.

키워드

참고문헌

  1. Ahmad, S., Ghani, F. and Adil, R. (2009), "Seismic friction base isolation performance using demolished waste in masonry housing", Constr. Build. Mater., 23(1), 146-152. https://doi.org/10.1016/j.conbuildmat.2008.01.012
  2. Ariga, T., Kanno, Y. and Takewaki, I. (2006), "Resonant behavior of base-isolated high-rise buildings under long-period ground motions", Struct. Des. Tall Spec., 15(3), 325-338 https://doi.org/10.1002/tal.298
  3. Christopoulos, C. and Filiatrault, A. (2006), Principle of passive supplemental damping and seismic isolation, IUSS Press, University of Pavia, Italy.
  4. Hanson, R.D. and Soong, T.T. (2001), Seismic design with supplemental energy dissipation devices, EERI, Oakland, CA.
  5. Indian Standard: 1893 (Part 1) (2002), Criteria for earthquake resistant design of buildings, BIS, New Delhi.
  6. Jangid, R.S. (1996), "Seismic response of sliding structures to bi-directional earthquake excitation", Earthq. Eng. Struct. D., 25(11), 1301-1306. https://doi.org/10.1002/(SICI)1096-9845(199611)25:11<1301::AID-EQE618>3.0.CO;2-3
  7. Jangid, R.S. (2005), "Computational numerical models for seismic response of structures isolated by sliding systems." Struct. Control Hlth. Monit., 12(1), 117-137. https://doi.org/10.1002/stc.59
  8. Kramer, S.L. (2004), Geotechnical earthquake engineering, Pearson Education Pvt. Ltd., Delhi.
  9. Masashi, I., Matsui, K. and Kosaka, I. (1992), "Analytical expressions for three different modes in harmonic motion of sliding structures", Earthq. Eng. Struct. D., 21(9), 757-769. https://doi.org/10.1002/eqe.4290210902
  10. Moler, C.B. (2004), Numerical Computing with MATLAB, SIAM, Philadelphia.
  11. Mostaghel, N. and Tanbakuchi, J. (1983), "Response of sliding structure to earthquake support motion", Earthq. Eng. Struct. D., 11(6), 729-748. https://doi.org/10.1002/eqe.4290110603
  12. Mostaghel, N., Hejazi, M. and Tanbakuchi, J. (1983), "Response of sliding structures to harmonic support motion", Earthq. Eng. Struct. D., 11(3), 355-366. https://doi.org/10.1002/eqe.4290110305
  13. Moustafa, A., Ueno, K. and Takewaki, I. (2010), "Critical earthquake loads for SDOF inelastic structures considering evolution of seismic waves", Earthq. Struct., 1(2), 147-162. https://doi.org/10.12989/eas.2010.1.2.147
  14. Naeim, F. and Kelly, J.M. (1999), Design of seismic isolated structures, John Wiley & Sons, New York.
  15. Nanda, R.P., Agarwal, P. and Shrikhande, M. (2010), "Frictional base isolation by geotextiles for brick masonry buildings", Geosynth. Int., 17(1), 48-55. https://doi.org/10.1680/gein.2010.17.1.48
  16. Nanda, R.P., Agarwal, P. and Shrikhande, M. (2011), "Base isolation by geosynthetic for brick masonry buildings", J. Vib. Control., 21 Sept. 2011, DOI: 10.1177/1077546311412411.
  17. Nikolic-Brzev, S. (1993), "Seismic protection of multi-storey brick buildings by seismic isolation technique", Ph.D Thesis, Department of Earthquake Engineering, University of Roorkee, Roorkee, India.
  18. Oliveto, N.D., Scalia, G. and Oliveto, G. (2008), "Dynamic identification of structural system with viscous and friction damping", J. Sound Vib., 318(4-5), 911-926. https://doi.org/10.1016/j.jsv.2008.04.026
  19. Ozbulut, O.E. and Hurlebaus, S. (2010), "Evaluation of the performance of a sliding-type base isolation system with a NiTi shape memory alloy device considering temperature effects", Eng. Struct., 32(1), 238-249. https://doi.org/10.1016/j.engstruct.2009.09.010
  20. Qamaruddin, M. and Ahmad, S. (2007), "Seismic response of pure-friction base isolation masonry building with restricted base sliding", J. Eng. Res., 4(1), 82-94. https://doi.org/10.24200/tjer.vol4iss1pp82-94
  21. Shakib, H. and Fuladgar, A. (2003), "Effect of vertical component of earthquake on the response of pure-friction base-isolated asymmetric buildings", Eng. Struct., 25(14), 1841-1850. https://doi.org/10.1016/j.engstruct.2003.08.008
  22. Soong, T.T. and Dargush, G.F. (1997), Passive energy dissipation systems in structural engineering, John Wiley & Sons, Chichester.
  23. Takewaki, I. (2001), "A new method for nonstationary random critical excitation", Earthq. Eng. Struct. D., 30(4), 519-535. https://doi.org/10.1002/eqe.21
  24. Takewaki, I. (2007), Critical Excitation Methods in Earthquake Engineering, Elsevier, UK.
  25. Takewaki, I. (2008), "Robustness of base-isolated high-rise buildings under code-specified ground motions", Struct. Des. Tall Spec., 17(2), 257-271. https://doi.org/10.1002/tal.350
  26. Takewaki, I. (2009), Building control with passive dampers: -optimal performance-based design for earthquakes, John Wiley & Sons Ltd. (Asia).
  27. Tsopelas, P., Constantinou, M.C., Kim, Y.S. and Okamoto, S. (1996), "Experimental study of FPS system in bridge seismic isolation", Earthq. Eng. Struct. D., 25(1), 65-78. https://doi.org/10.1002/(SICI)1096-9845(199601)25:1<65::AID-EQE536>3.0.CO;2-A
  28. Vanmarcke, E.H. (1976), Structural response to earthquakes., Eds. C. Lomnitz and E. Rosenblueth, Seismic Risk and Engineering Decisions, Elsevier, Amsterdam.
  29. Westermo, B. and Udwadia, F. (1983), "Periodic response of a sliding oscillator system to harmonic excitation", Earthq. Eng. Struct. D., 11(1), 135-146. https://doi.org/10.1002/eqe.4290110111

피인용 문헌

  1. New experimental system for base-isolated structures with various dampers and limit aspect ratio vol.5, pp.4, 2013, https://doi.org/10.12989/eas.2013.5.4.461
  2. Geosynthetic Liner as Foundation Isolation for Seismic Protection vol.3, pp.3, 2017, https://doi.org/10.1007/s40891-017-0098-2
  3. Low-Cost Base-Isolation System for Seismic Protection of Rural Buildings vol.21, pp.1, 2016, https://doi.org/10.1061/(ASCE)SC.1943-5576.0000254
  4. Shake Table Study on the Efficiency of Seismic Base Isolation Using Natural Stone Pebbles vol.2018, pp.None, 2012, https://doi.org/10.1155/2018/1012527
  5. Geotechnical Seismic Isolation System Based on Sliding Mechanism Using Stone Pebble Layer: Shake-Table Experiments vol.2019, pp.None, 2019, https://doi.org/10.1155/2019/9346232
  6. Assessment of Geotechnical Seismic Isolation (GSI) as a Mitigation Technique for Seismic Hazard Events vol.10, pp.6, 2020, https://doi.org/10.3390/geosciences10060222
  7. Foundation size effect on the efficiency of seismic base isolation using a layer of stone pebbles vol.19, pp.2, 2020, https://doi.org/10.12989/eas.2020.19.2.103