Acknowledgement
Supported by : Korea Science and Engineering Foundation (KOSEF), Ministry of Land, Transport and Maritime Affairs
References
- Agrawal, A.K. and Yang, J.N. (1999), "Optimal placement of passive dampers on seismic and wind-excited buildings using combinatorial optimization", J. Intel. Mat. Syst. Str., 10(12), 997-1013. https://doi.org/10.1106/YV3B-TP5H-HWQ2-X1OK
- Chang, C.C. and Hsu, C.T. (1998), "Control performance of liquid column vibration absorbers", Eng. Struct., 20(7), 580-86. https://doi.org/10.1016/S0141-0296(97)00062-X
- Chang, C.C. and Qu, W.L. (1998), "Unified dynamic absorber design formulas for wind-indeuced vibration control of tall buildings", Struct. Des. Tall Spec., 7, 147-66.
- Colwell, S. and Basu, B. (2008), "Experimental and theoretical investigations of equivalent viscous damping of structures with TLCD for different fluids", J. Struct. Eng. - ASCE, 134(1), 154-163. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:1(154)
- Davenport, A.G. (1961), "The spectrum of horizontal gustiness near the ground in high winds", Q. J. Roy. Meteorol. Soc., 87(372), 194-211. https://doi.org/10.1002/qj.49708737208
- Davenport, A.G. (1964), "Note on the distribution of the largest value of a random function with application to gust loading", Proceedings of the Institution of Civil Engineers, London.
- Gao, H., Kwok, K.C.S. and Samali, B. (1997), "Optimization of tuned liquid column dampers", Eng. Struct., 19(6), 476-86. https://doi.org/10.1016/S0141-0296(96)00099-5
- Gao, H., Kwok, K.C.S. and Samali, B. (1999), "Characteristics of multiple tuned liquid column dampers in suppressing structural vibration", Eng. Struct., 21(4), 316-31. https://doi.org/10.1016/S0141-0296(97)00183-1
- Heo, J.S., Lee, S.K., Park, E., Lee, S.H., Min, K.W., Kim, H., Jo, J. and Cho, B.H. (2009), "Performance test of a tuned liquid mass damper for reducing bidirectional responses of building structures", Struct. Des. Tall Spec., 18(7), 789-805. https://doi.org/10.1002/tal.486
- Hitchcock, P.A., Kwok, K.C.S., Watkins, R.D. and Samali, B. (1997), "Characteristics of liquid column vibration absorbers (LCVA)-I", Eng. Struct., 19(2), 126-134. https://doi.org/10.1016/S0141-0296(96)00042-9
- Hitchcock, P.A., Kwok, K.C.S., Watkins, R.D. and Samali, B. (1997), "Characteristics of liquid column vibration absorbers (LCVA)-II", Eng. Struct., 19(2), 135-44. https://doi.org/10.1016/S0141-0296(96)00044-2
- Housner, G.W., Bergman, L.A., Caughey, T.K., Chassiakos, A.G., Claus, R.O., Masri, S.F., Skelton, R.E., Soong, T.T., Spencer, B.F. and Yao, T.P. (1997), "Structural control: past, present and future", J. Eng. Mech. - ASCE, 123(9), 897-971. https://doi.org/10.1061/(ASCE)0733-9399(1997)123:9(897)
- Kareem, A. and Kijewski, T. (1999), "Mitigation of motions of tall buildings with specific examples of recent applications", Wind Struct., 2(3), 201-51. https://doi.org/10.12989/was.1999.2.3.201
- Mazza, F. and Vulcano, A. (2007), "Control of the along-wind response of steel framed buildings by using viscoelastic or friction dampers", Wind Struct., 10(3), 233-247. https://doi.org/10.12989/was.2007.10.3.233
- Mazza, F. and Vulcano, A. (2011), "Control of the earthquake and wind dynamic response of steel-framed buildings by using additional braces and/or viscoelastic dampers", Earth. Eng. Struct. D., 40(2), 155-174. https://doi.org/10.1002/eqe.1012
- Min, K.W., Kim, H.S., Lee, S.H., Kim, H. and Ahn, A.K. (2005), "Performance evaluation of tuned liquid column dampers for response control of a 76-story benchmark building", Eng. Struct., 27(7), 1101-12. https://doi.org/10.1016/j.engstruct.2005.02.008
- Sakai, F., Takaeda, S. and Tamaki, T. (1989), "Tuned liquid column damper - new type device for suppression of building vibration", Proceedings of the Conference on High-Rise Building.
- Shum, K.M. (2009), "Closed form optimal solution of a tuned liquid column damper for suppressing harmonic vibration of structures", Eng. Struct., 31(1), 84-92. https://doi.org/10.1016/j.engstruct.2008.07.015
- Simiu, E. and Scanlan, R.H. (1996), Wind effects on structures: fundamentals and applications to design, 3rd Ed., Wiley-Interscience, USA.
- Solnes, J. (1997), Stochastic processes and random vibrations: theory and practice, John Wiley & Sons, Chichester, West Sussex, ENG.
- Soong, T.T. and Dargush, G.F. (1997), Passive energy dissipation systems in structural engineering, Joh Wiley & Sons, USA.
- Watkins, R.D. (1991), Tests on various arrangements of liquid column vibration absorbers, Research Report R639. School of Civil and Mining Engineering, University of Sydney.
- Wu, J.C., Shih, M.H., Lin, Y.Y. and Shen, Y.C. (2005), "Design guidelines for tuned liquid column damper for structures responding to wind", Eng. Struct., 27(13), 1893-1905. https://doi.org/10.1016/j.engstruct.2005.05.009
- Yalla, S.K. and Kareem, A. (2000), "Optimum absorber parameters for tuned liquid column dampers", J. Struct. Eng.- ASCE, 126(8), 906-15. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:8(906)
- Yang, J.N., Agrawal, A.K., Samali, B. and Wu, J.C. (2004), "Benchmark Problem for Response Control of Wind-Excited Tall Buildings", J. Eng. Mech.- ASCE, 130(4), 437-443. https://doi.org/10.1061/(ASCE)0733-9399(2004)130:4(437)
Cited by
- A design procedure of two-way liquid dampers for attenuation of wind-induced responses of tall buildings vol.129, 2014, https://doi.org/10.1016/j.jweia.2014.03.003
- Bidirectional wind response control of 76-story benchmark building using active mass damper with a rotating actuator vol.25, pp.10, 2018, https://doi.org/10.1002/stc.2216