DOI QR코드

DOI QR Code

Design tables and charts for uniform and non-uniform tuned liquid column dampers in harmonic pitching motion

  • Wu, Jong-Cheng (Department of Civil Engineering, Tamkang University) ;
  • Wang, Yen-Po (Department of Civil Engineering, National Chiao Tung University) ;
  • Chen, Yi-Hsuan (Department of Civil Engineering, National Chiao Tung University)
  • Received : 2011.01.31
  • Accepted : 2012.02.02
  • Published : 2012.02.25

Abstract

In the first part of the paper, the optimal design parameters for tuned liquid column dampers (TLCD) in harmonic pitching motion were investigated. The configurations in design tables include uniform and non-uniform TLCDs with cross-sectional ratios of 0.3, 0.6, 1, 2 and 3 for the design in different situations. A closed-form solution of the structural response was used for performing numerical optimization. The results from optimization indicate that the optimal structural response always occurs when the two resonant peaks along the frequency axis are equal. The optimal frequency tuning ratio, optimal head loss coefficient, the corresponding response and other useful quantities are constructed in design tables as a guideline for practitioners. As the value of the head loss coefficient is only available through experiments, in the second part of the paper, the prediction of head loss coefficients in the form of a design chart are proposed based on a series of large scale tests in pitching base motions, aiming to ease the predicament of lacking the information of head loss for those who wishes to make designs without going through experimentation. A large extent of TLCDs with cross-sectional ratios of 0.3, 0.6, 1, 2 and 3 and orifice blocking ratios ranging from 0%, 20%, 40%, 60% to 80% were inspected by means of a closed-form solution under harmonic base motion for identification. For the convenience of practical use, the corresponding empirical formulas for predicting head loss coefficients of TLCDs in relation to the cross-sectional ratio and the orifice blocking ratio were also proposed. For supplemental information to horizontal base motion, the relation of head loss values versus blocking ratios and the corresponding empirical formulas were also presented in the end.

Keywords

Acknowledgement

Supported by : National Science Council of Taiwan

References

  1. Balendra, T., Wang, C.M. and Cheong, H.F. (1995), "Effectiveness of tuned liquid column dampers for vibration control of towers", Eng. Struct., 17(9), 668-675. https://doi.org/10.1016/0141-0296(95)00036-7
  2. Balendra, T., Wang, C.M. and Rakesh, G. (1999a), "Effectiveness of TLCD on various structural systems", Eng. Struct., 21(4), 291-305. https://doi.org/10.1016/S0141-0296(97)00156-9
  3. Balendra, T., Wang, C.M. and Rakesh, G. (1999b), "Vibration control of various types of buildings using TLCD", J. Wind Eng. Ind. Aerod., 83(1-3), 197-208. https://doi.org/10.1016/S0167-6105(99)00072-0
  4. Chakraborty, S. and Debbarma, R. (2011), "Stochastic earthquake response control of structures by liquid column vibration absorber with uncertain bounded system parameters", Struct. Saf., 33(2), 136-144 https://doi.org/10.1016/j.strusafe.2011.01.001
  5. Chang, C.C. and Hsu, C.T. (1998), "Control performance of liquid column vibration absorbers", Eng. Struct., 20(7), 580-586. https://doi.org/10.1016/S0141-0296(97)00062-X
  6. Chang, C.C. (1999), "Mass dampers and their optimal designs for building vibration control", Eng. Struct., 21(5), 454-463. https://doi.org/10.1016/S0141-0296(97)00213-7
  7. Chang, C. H. (2011), "Computational fluid dynamics simulation for tuned liquid column dampers in horizontal motion", Wind Struct., 14(5), 435-447. https://doi.org/10.12989/was.2011.14.5.435
  8. Debbarma, R., Chakraborty, S. and Kumar, G.S. (2011), "Optimum design of tuned liquid column dampers under stochastic earthquake load considering uncertain bounded system parameters", Int. J. Mech. Sci., 52(10), 1385- 1393.
  9. Den Hartog, J.P. (1956), Mechanical Vibrations, 4th Ed., McGraw-Hill, NY.
  10. Gao, H., Kwok, K.C.S. and Samali, B. (1997), "Optimization of tuned liquid column damper", Eng. Struct., 19(6), 476-86. https://doi.org/10.1016/S0141-0296(96)00099-5
  11. Heo, J. S., Lee, S.K., Park, E., Lee, S.H., Min, K.W., Kim, H., Jo, J. and Cho, B.H. (2009) "Performance test of a tuned mass damper for reducing bidirectional response of building structures", Struct. Des. Tall Spec., 18(7), 789-805. https://doi.org/10.1002/tal.486
  12. Hitchcock, P.A., Kwok, K.C.S. and Watkins, R.D. (1997), "Characteristics of liquid column vibration absorbers (LCVA) - I, II", Eng. Struct., 19, 126-44. https://doi.org/10.1016/S0141-0296(96)00042-9
  13. Li, S. K., Min, K.W. and Lee, H. R. (2011), "Parameter identification of new bidirectional tuned liquid column and sloshing dampers", J. Sound Vib., 330(7), 1312-1327. https://doi.org/10.1016/j.jsv.2010.10.016
  14. Sakai, F., Takaeda, S. and Tamaki, T. (1989), "Tuned liquid column damper-new type device for suppression of building vibration", Proceedings of the International Conference on High-rise Building, Nanjing. China.
  15. Shum, K.M. and Xu, Y.L. (2002), "Multiple-tuned liquid column dampers for torsional vibration control of structures: experimental investigation", Earthq. Eng. Struct. D., 31, 977-991. https://doi.org/10.1002/eqe.133
  16. Skelton, R.E. (1988), Dynamic systems control: Linear systems analysis and synthesis, Wiley, NY.
  17. Taflanidis, A.A., Angelides, D.C. and Manos, G.C. (2005), "Optimal design and performance of liquid column mass dampers for rotational vibration control of structures under white noise excitation", Eng. Struct., 27(4), 524-534. https://doi.org/10.1016/j.engstruct.2004.11.011
  18. Won, A., Pires, J.A. and Haroun, M.A. (1997), "Performance assessment of tuned liquid column dampers under random seismic loading", Int. J. Nonlinear Mech., 32(4), 745-758. https://doi.org/10.1016/S0020-7462(96)00118-7
  19. Wu, J.C., Shih, M.H., Lin, Y.Y. and Shen, Y.C. (2005), "Design guidelines for tuned liquid column damper for structures responding to wind", Eng. Struct., 27(13), 1893-1905. https://doi.org/10.1016/j.engstruct.2005.05.009
  20. Wu, J.C., Wang, Y.P., Lee, C.L., Liao, P.H. and Chen, Y.H. (2008), "Wind-induced interaction of a non-uniform tuned liquid column damper and a structure in pitching motion", Eng. Struct., 30(12), 3555-3565. https://doi.org/10.1016/j.engstruct.2008.05.029
  21. Wu, J.C., Chang, C.H. and Lin, Y.Y. (2009), "Optimal designs for non-uniform tuned liquid column dampers in horizontal motion", J. Sound Vib., 326(1-2), 104-122. https://doi.org/10.1016/j.jsv.2009.04.027
  22. Xu, Y.L., Samali, B. and Kwok, K.C.S. (1992), "Control of along-wind response of structures by mass and liquid dampers", J. Eng. Mech.- ASCE , 118(1), 20-39. https://doi.org/10.1061/(ASCE)0733-9399(1992)118:1(20)
  23. Xu, Y.L. and Shum, K.M. (2003), "Multiple-tuned liquid column dampers for torsional vibration control of structures: theoretical investigation", Earthq. Eng. Struct. D., 32(2), 309-328. https://doi.org/10.1002/eqe.227
  24. Xue, S.D., Ko, J.M. and Xu, Y.L. (2000a), "Tuned liquid column damper for suppressing pitching motion of structures", Eng. Struct., 23(11), 1538-1551.
  25. Xue, S.D., Ko, J.M. and Xu, Y.L. (2000b), "Optimum parameters of tuned liquid column damper for suppressing pitching vibration of an undamped structure", J. Sound Vib., 235(4), 639-653. https://doi.org/10.1006/jsvi.2000.2947
  26. Yalla, S. and Kareem, A. (2000), "Optimum absorber parameters for tuned liquid column dampers", J. Struct. Eng - ASCE, 126(8), 906-915. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:8(906)

Cited by

  1. Innovative modeling of tuned liquid column damper controlled structures vol.18, pp.1, 2016, https://doi.org/10.12989/sss.2016.18.1.117
  2. Experimental Study on Variation Rules of Damping with Influential Factors of Tuned Liquid Column Damper vol.2017, 2017, https://doi.org/10.1155/2017/6209205
  3. Tuned liquid column damper for suppressing pitching motion of a floating rectangular box structure vol.24, pp.11, 2017, https://doi.org/10.1002/stc.2014
  4. Effects of TLCD with maneuverable flaps on vibration control of a SDOF structure vol.52, pp.6, 2017, https://doi.org/10.1007/s11012-016-0473-4
  5. A New Energy-Absorbing Device for Motion Suppression in Deep-Sea Floating Platforms vol.8, pp.12, 2015, https://doi.org/10.3390/en8010111
  6. Vibration Mitigation of Structures through TLCD with Embedded Baffles vol.41, pp.2, 2017, https://doi.org/10.1007/s40799-016-0163-0
  7. Optimum LCVA for suppressing harmonic vibration of damped structures vol.20, pp.4, 2012, https://doi.org/10.12989/sss.2017.20.4.461
  8. Experimental comparison of nonlinear damping performance of toroidal and conventional tuned liquid column dampers vol.104, pp.4, 2012, https://doi.org/10.1007/s11071-021-06552-7
  9. Optimized parameters of toroidal tuned liquid column dampers for multidirectional pitching vibration mitigation of structures vol.64, pp.6, 2012, https://doi.org/10.1007/s00158-021-03015-w