Abstract
Compression splices are required for all compression members in almost all of the floors in high-rise buildings. Therefore, a clear understanding of the behavior of compression splices can provide a rational design of compression splices. Tests of compression splices with bearing only and bond only cases were conducted to investigate the component resistance characteristics of compression splices. Test results showed that the circumferential tensile stresses induced by bearing and bond overlapped at the end of the splice length deterred bond and bearing splices from developing target splicing strength when both normal bond and bearing splices were used. In particular, the bearing strength was more significantly reduced than the bond strength since the bearing relied on the limited area near the end of the splice length. However, the strength of the normal splice was always higher than the strength of the bond only or the bearing only case. Consequently, the study results showed that splice strength in compression cannot be improved by means of removing bond or bearing. In addition, the bond strength in bond only splices was nearly same as the bond strength in tension splices and the strength increase of compression splice is attributed to end bearing only characteristic.
철근 압축이음은 초고층 건축물의 수직 부재에서 거의 모든 층에서 발생되므로, 압축이음 거동에 대한 명확한 이해는 합리적인 이음부 설계에 필수 요소가 된다. 이 연구에서는 압축을 받는 철근이음의 인자별 특성을 분석하기 위해, 부착 또는 지압만 존재하는 압축이음 실험을 수행하였다. 실험 결과 부착과 지압이 함께 존재하는 일반이음에서는 부착과 지압의 상호 간섭으로 각각의 고유 강도가 100% 발현되지는 않았다. 특히 지압은 국부적인 영역에서 발현되므로 중첩으로 인한 감소량이 부착에 비해 컸다. 부착과 지압이 함께 존재하는 일반이음은 부착이음과 지압이음에 비해 동일하중에서 콘크리트와 철근의 상대변위를 줄일 수 있다. 이음 파괴는 콘크리트와 철근 사이의 과도한 상대변위로 인해 발생되므로 일반이음의 강도가 부착이음과 지압이음에 비해 항상 높아진다. 따라서 부착 또는 지압을 제거함으로써 압축이음강도를 향상시킬 수는 없다. 또한 부착이음에서 순수 부착강도는 인장이음의 부착강도와 거의 유사하게 나타났으므로, 압축이음강도가 인장이음강도보다 큰 것은 지압의 영향임을 알 수 있다.