DOI QR코드

DOI QR Code

Physical Activity Monitoring Using PVDF Film-Embedded Elastic Belt

PVDF 필름 내장 탄성벨트를 이용한 운동강도 모니터링

  • Ahn, Yu Jin (Department of Advanced Materials Engineering for Information & Electronics, College of Engineering, Kyung Hee University) ;
  • Kim, Kap Jin (Department of Advanced Materials Engineering for Information & Electronics, College of Engineering, Kyung Hee University)
  • 안유진 (경희대학교 공과대학 정보.전자 신소재공학과) ;
  • 김갑진 (경희대학교 공과대학 정보.전자 신소재공학과)
  • Received : 2012.10.23
  • Accepted : 2012.12.08
  • Published : 2012.12.31

Abstract

Pedometer, tri-axial accelerometer, and measuring system of $CO_2$ generated during metabolism have mainly been used to measure the quantity of motion and inhaling capacity while walking or running. However, these sensors are heavy, expensive, and uncomfortable to wear and difficult to check the work-out condition. In an attempt to overcome these limitations, a soft, flexible, and lightweight piezoelectric polymer-based sensor has been prepared. The PVDF film sensor with thin silver-paste layers in both sides was coated with silicon rubber to amplify stress by the external power such as tension and pressure. Thus, movement of thigh muscles was monitored and physical activity was predicted during walking and running, with an elastic belt embedded with the prepared PVDF film sensor, which was named as a physiological sensing belt (PSB), strapped on the thigh.

Keywords

Acknowledgement

Supported by : 한국연구재단(NRF), 지식경제부(MKE)

References

  1. J. Tan, Ed., "E-Health Care Information Systems: An Introduction for Students and Professionals", San Francisco, Jossey-Bass, 2005.
  2. 권성미, "공공부문의 u-Health 도입방안", 정보통신정책, 2006, 통권 407호, 19-45.
  3. Y. J. Ahn, S. Yoon, and K. J. Kim, “Preparation of Conductive Nanoweb through Electrospinning Followed by Electroless Silver-Plating and Its Application as Dry-Type Electrode for ECG Measurement”, Text Sci Eng, 2012, 49, 47-55. https://doi.org/10.12772/TSE.2012.49.1.047
  4. K. J. Kim, S. Yoon, and Y. J. Ahn, "Silver-plated Nanoweb and Dry-type Electrode Using There of", Korean Patent Application 10-2012-0014321(2012).
  5. J. R. Doud and J. M. Walsh, “Muscle Fatigue and Muscle Length Interaction: Effect on the EMG Frequency Components”, Electromyogr Clin Neurophysiol, 1995, 35(6), 331-339.
  6. L. A. Jones and I. W. Hunter, “The Relation of Muscle Force and EMG to Perceived Force in Human Finger Flexors”, Eur J Appl Physiol, 1982, 50, 125-131. https://doi.org/10.1007/BF00952251
  7. A. Erdemir, S. McLean, W. Herzog, and A. J. van den Bogert, "Model-based Estimation of Muscle Forces Exerted during Movements", Clinical Biomechanics, 2007, 22, 131-154. https://doi.org/10.1016/j.clinbiomech.2006.09.005
  8. M. C. Bisi, R. Stagni, H. Houdijk, and G. J. Gnudi, “An EMG-driven Model Applied for Predicting Metabolic Energy Consumption during Movement”, J Electromyogr Kinesiol, 2011, 21, 1074-1080. https://doi.org/10.1016/j.jelekin.2011.07.003
  9. Y. M. Chang, J. S. Lee, and K. J. Kim, “Heartbeat Monitoring Technique Based on Corona-poled PVDF Film Sensor for Smart Apparel Application”, Solid State Phenom, 2007, 124-126, 299-302. https://doi.org/10.4028/www.scientific.net/SSP.124-126.299
  10. K. J. Kim, S. Yoon, Y. M. Chang, and J. S. Lee, "Application of Uniaxially Stretched PVDF Piezoelectric Film for Medical Diagnosis", Proceedings of the 9th Asian Textile Conference, Taichung, Taiwan, 2007, p.98.
  11. Y. M. Chang, S. Yoon, and H. J. Kim, “A Novel Piezoelectric PVDF Film-based Physiological Sensing Belt for a Complementary Respiration and Heartbeat Monitoring System”, Integr Ferroelectr, 2009, 107, 53-68. https://doi.org/10.1080/10584580903324493
  12. K. J. Kim, H. J. Kim, Y. M. Chang, and S. Yoon, "Sensor Comprising a Material Which Generates an Electrical Signal in Response to Elongation", Korean Patent 10-1023446, (2011).
  13. K. J. Kim, S. Yoon, and Y. J. Ahn, "The Method of Manufacturing Piezoelectric Sensor Having Carbon Black", Korean Patent Application 10-2012-0114168(2012).
  14. Y. J. Ahn, S. Yoon, and K. J. Kim, "Respiration Monitoring Using an Electromagnetic Interference Shielding PVDF Film-Imbedded Elastic Belt", Text Sci Eng, 2012, 49, 392-401. https://doi.org/10.12772/TSE.2012.49.6.392
  15. W. Tharion, M. Yokota, M. Buller, J. DeLany, and R. Hoyt, “Total Energy Expenditure Estimated Using a Foot-contact Pedometer”, Med Sci Monit, 2004, 10, CR504-509.
  16. H. Vathsangam, B. A. Emken, E. T. Schroeder, D. Spruijt- Metz, and G. S. Sukhatme, "Energy Estimation of Treadmill Walking using On-body Accelerometers and Gyroscopes", 32nd Annual International Conference of the IEEE EMBS, Buenos Aires, Argentina, 2010, pp.6497-6501.
  17. K. Khalaj-Hedayati, A. Bosy-Westphal, M. J. Mller, and M. Dittmar, “Validation of the BIOPAC Indirect Calorimeter for Determining Resting Energy Expenditure in Healthy Freeliving Older People”, Nutrit Res, 2009, 29, 531-541. https://doi.org/10.1016/j.nutres.2009.08.001