Effect of Temperature and Bake-out on Formaldehyde Emission from UF Bonded Wood Composites

  • Lee, Young-Kyu (Indoor Air Quality Analysis Center, National Instrumentation Center for Environmental Management, Seoul National University) ;
  • Kim, Hyun-Joong (Laboratory of Adhesion and Bio-Composites, Program in Environmental Materials Science, Seoul National University)
  • 투고 : 2012.01.30
  • 심사 : 2012.03.20
  • 발행 : 2012.03.25

초록

This study analysis the effect of various temperatures (20, 35 and $50^{\circ}C$) on the formaldehyde emission from wood composites, which were particleboard (PB), medium density fiberboard (MDF), high density fiberboard (HDF) and laminated HDF (L-HDF) by Japanese desiccator method. Also, to reduce formaldehyde emission by wood composites, it has been suggested that undergo a bake-out conditions. On average, the level of formaldehyde emission increased many times with a $15^{\circ}C$ increase in temperature from 20 to $35^{\circ}C$ for PB, MDF, HDF and L-HDF, respectively. Formaldehyde emissions from wood composites could be expected to increase with increasing ambient temperature. At $35$ for 28 days bake-out treatment of boards, the free formaldehyde emission reduced 67.8% (PB), 40.1% (MDF), 37.8% (HDF), and 35.2% (L-HDF). On the other hand, after the bake-out at $50^{\circ}C$ for 28 days, the formaldehyde concentration decreased by 88.2, 66.9, 62.2 and 59.3% of the concentration before the bake-out for PB, MDF, HDF and L-HDF, respectively. An interesting of the bake-out treatment at $50^{\circ}C$ after 14 days, formaldehyde emission grade of PB & MDF down $E_2$ to $E_1$, and HDF & L-HDF down $E_1$ to $E_0$.

키워드

참고문헌

  1. Van Der Wal, J. F., A. W. Hoogeveen, and P. Wouda. 1997. Indoor Air 7: 215-221. https://doi.org/10.1111/j.1600-0668.1997.t01-1-00007.x
  2. Park, B. I., H. T. Seok, and K.-W. Kim. 1995. Air Conditioning and Refrigeration Engineering 24(6): 613-627.
  3. Song, G.-S. 2005. Energy and Buildings 37: 65 -75 (2005). https://doi.org/10.1016/j.enbuild.2004.05.005
  4. Tuomainen, M., A. L. Pasanen, A. Tuomainen, J. Liesivuori, and P. Juvonen. 2001. Atmospheric Environment 35: 305-313. https://doi.org/10.1016/S1352-2310(00)00157-6
  5. Girman, J. R., L. E. Alevantis, G. C. Kulasingam, M. X. Petreas, and L. M. Webber. 1989. Environment International 15: 449-453. https://doi.org/10.1016/0160-4120(89)90061-5
  6. Japanese Industrial Standard. 2001. JIS A 1460, Building boards determination of formaldehyde emission desiccator method, Japanese Industrial Standards Association.
  7. Evaluation of VOC emissions from building products. 1997. Solid Flooring materials European Collaborative Action Indoor Air Quality & Its Impact on Man, Report No. 18, European Commission Joint Research Institute Environmental Institute.
  8. Rybicky, J., J. Horst, and S. M. Kambanis. 1983. Forest Products Journal 33(9): 50-54.
  9. Wolcott, M. P., F. A. Kamke, and D. A Dillard. 1990. Wood and Fiber Science 22(4): 345-361.
  10. Sollinger, S., K. Levsen, and G. Wunsch, 1993. Atmospheric Environment 27B: 183-192.
  11. Lee, Y. K. and H.-J. Kim. 2012. Building and Environment 53: 95-99. https://doi.org/10.1016/j.buildenv.2011.10.016
  12. Girman, J., L. Alevantis, G. Kulasingam, M. Petreas, and L. Webber. 1987. in Proceeding of the Fourth International Conference on Indoor Air Quality and Climate, Vol. 1. Institute for Water, Soil, and Air Hygiene, pp.22-26, Berlin, Germany.
  13. Girman, J. R. 1987. In Proceeding of Problem Build- ings: Building-Associated Illness and the Sick Building Syndrome. Hanley & Belfus, Inc., pp. 695-712, Philadelphia, USA.
  14. Follin, T. 1997. In Proceedings of Healthy Buildings/IAQ'97, Vol. 3, Healthy Buildings/ IAQ'97, pp. 353-356. Washington, USA.
  15. Bayer, C. W. 1990. In Proceedings of the Fifth International Conference on Indoor Air Quality and Climate, Vol. 3. Canada Mortgage and Housing Corporation, pp. 581-586 Ottawa.
  16. Bayer, C. W. 1991. In Proceeding of Indoor Air Pollution: Radon, Bioaerosols, and VOCs. Lewis Publishers, Inc., pp. 101-113, Michigan, USA.
  17. Offerman, F. J., S. A. Loiselle, G. Ander, and H. Lau. 1993. In Proceedings of the ASHRAE Conference IAQ'93. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Philadelphia, USA.
  18. Levin, H. 1989. In Proceeding of Problem Buildings: Building-Associated Illness and the Sick Building Syndrome. Hanley & Belfus, Inc., pp. 667-669, Philadelphia, USA.