Arthroscopic Diagnosis of Polyethylene Wear of Meniscal Bearing in Unicompartmental Knee Arthroplasty - A Case Report -

인공 슬관절 단일구획 치환술 후 폴리에틸렌 마모의 관절경적 진단 - 증례 보고 -

  • Kang, Kyu-Bok (Department of Orthopedic Surgery, Seoul Veterans Hospital) ;
  • Yoon, Jung-Ro (Department of Orthopedic Surgery, Seoul Veterans Hospital) ;
  • Park, Sung-Chul (Department of Orthopedic Surgery, Seoul Veterans Hospital) ;
  • Song, Seungyeop (Department of Orthopedic Surgery, Seoul Veterans Hospital) ;
  • Yang, Jae-Hyuk (Department of Orthopedic Surgery, Seoul Veterans Hospital)
  • 강규복 (서울보훈병원 정형외과) ;
  • 윤정로 (서울보훈병원 정형외과) ;
  • 박성철 (서울보훈병원 정형외과) ;
  • 송승엽 (서울보훈병원 정형외과) ;
  • 양재혁 (서울보훈병원 정형외과)
  • Received : 2012.07.10
  • Accepted : 2012.08.14
  • Published : 2012.08.31

Abstract

The role of arthroscopy for the diagnosis of polyethylene wear after total knee arthroplasty has been reported previously. In this report, we demonstrate a case of wear of meniscal bearing in unicompartmental knee arthroplasty (UKA) and recurrent meniscal bearing subluxation which was diagnosed by arthroscopy. Arthroscopic examination has its role in diagnosing the wear and subluxation of polyethylene bearing after UKA.

인공 슬관절 전치환술 후 발생한 폴리에틸렌 마모를 관절경을 통한 진단은 이전에 보고된 바 있다. 이번 논문에서 저자들은 인공 슬관절 단일구획 치환술 후 발생된 폴리에틸렌 마모와 재발성 아탈구를 관절경을 통해 진단하여 폴리에틸렌의 교환만으로 치료된 증례에 대해 보고하는 바이다. 인공 슬관절 단일구획 치환술 후 발생된 폴리에틸렌 마모와 탈구의 진단에 관절내시경이 도움이 되며 문제의 원인, 진단 및 치료 방침을 정하는데 유용한 것으로 사료된다.

Keywords