Shorted Turn in the Flat Coil Actuator for Fast Initial Response

  • Hwang, Ki-Il (Department of Mechanical Engineering, Yeungnam Univertity) ;
  • Seo, Tae-Won (Department of Mechanical Engineering, Yeungnam Univertity) ;
  • Song, Bong-Sob (Department of Mechanical Engineering, Ajou University) ;
  • Kim, Jin-Ho (Department of Mechanical Engineering, Yeungnam Univertity)
  • Received : 2011.12.01
  • Accepted : 2012.02.15
  • Published : 2012.03.31

Abstract

This paper presents an analysis and experiment of the flat coil actuator with shorted turn. The flat coil actuator is widely used in high precision products because it has no friction between the moving coil and the guide. A shorted turn and a center pole are placed into the flat coil actuator in order to reduce the inductance of the coil and improve the initial response when the actuator is voltage-driven. Enhanced dynamic performance of the flat coil actuator with shorted turn was demonstrated by simulation and experiment.

Keywords

References

  1. M. Hiyane, Y. Inoue, and M. Kurusu, Fujitsu Scientific and Technical Journal, 2, 59 (1972).
  2. H. Shinno and H. Hashizume, CIRP Annals-Manufacturing 50, 243 (2001). https://doi.org/10.1016/S0007-8506(07)62114-3
  3. J. Arthur Wagner, IEEE Trans. Magn. 18, 1770 (1983). https://doi.org/10.1109/TMAG.1982.1062201
  4. Y. Hirano, J. Naruse, and R. Tsuchiyama, IEEE Trans. Magn. 25, 3073 (1989). https://doi.org/10.1109/20.34373
  5. C. Dong, IEEE Trans. Magn. 19, 1689 (1983). https://doi.org/10.1109/TMAG.1983.1062721
  6. T. S. Liu and C. W. Yeh, IEEE Mediterranean Electrotechnical Conference 1153 (2010).
  7. J. P. Wang, D. K. Lieu, W. L. Lorimer, and A. Hartman, IEEE Trans. Magn. 33, 4092 (1997). https://doi.org/10.1109/20.619673