DOI QR코드

DOI QR Code

Study on the Performance Characteristics of the Thermosyphon Used for the Vehicle Operated at Low Temperature Conditions

저온작동 조건에서 자동차용 써모사이폰의 성능특성에 관한 연구

  • 임택규 (자동차 부품 연구원 열제어시스템 연구센터) ;
  • 이호성 (자동차 부품 연구원 열제어시스템 연구센터) ;
  • 원종필 (자동차 부품 연구원 열제어시스템 연구센터) ;
  • 조중원 (자동차 부품 연구원 열제어시스템 연구센터) ;
  • 이무연 (자동차 부품 연구원 열제어시스템 연구센터)
  • Received : 2011.12.27
  • Accepted : 2012.02.10
  • Published : 2012.02.29

Abstract

The objective of this study is to investigate low temperature performance characteristics of the thermosyphon with/without wick. Thermosyphons using water as the working fluid are tested with variations of wick, charge amount of the working fluid, outdoor temperature, and heat load for the evaporator section at a low temperature. As a result, the heat transfer of thermosyphon was optimized at the charge amount of 40% and increased with the rise of the outdoor temperatures.

본 연구의 목적은 심지구조 유무에 따른 자동차에 적용된 써모사이폰의 저온 작동영역에서의 성능 특성을 고찰하는 것이다. 이를 위하여 작동유체로 물을 사용하는 써모사이폰을 제작하였고, 작동유체의 충진량, 심지 적용 유무, 외기온도 변화 그리고 증발부에 열부량 변화에 따른 성능 특성을 파악하였다, 결과적으로 작동유체의 충진량 40%에서 최적의 열전달 성능을 나타내고, 외기온도 증가에 따라 써모사이폰의 열전달 성능이 증가하였다.

Keywords

References

  1. C. W. Cho, M. Y. Lee, H. S. Lee, J. H. Mo, S. T. Oh, J. P. Won, "Heating Performance Characteristics of a Coolant Source Heat Pump using Wasted Heat of Electric Devices for an Electric Bus", Int. J. Automotive Technology, In Review, 2011.
  2. M. Y. Lee, C. W. Cho, H. S. Lee, D. Y. Lee, Y. C. Park, J. P. Won, "Performance Characteristics of a Simultaneous Hybrid Heat Pump using Coolant and Air Sources for an Electric Bus", Int. J. of Refrigeration, In Review, 2011.
  3. M. Y. Lee, J. P. Won, D. Y. Lee, C. W. Cho, "Study on the Performance Characteristics of the Roof Mounted Electrical Air Conditioning System Using Inverter Scroll Compressor", Journal of the KAIS, Vol. 12, No. 10, pp. 4308-4313, 2011. https://doi.org/10.5762/KAIS.2011.12.10.4308
  4. H. S. Lee, J. P. Won, C. W. Cho, M. Y. Lee, Y. C. Jung, H. B. Jeon, Y. C. Kim, "A Study on the Performance Characteristic of CO2 Mobile Air Conditioning Bench Tests with the Variation of Driving Conditions on the Road", Proceeding of KSAE 2011, 2011.
  5. S. E. Hong, "A study on the characteristics of a frozen start up for a variable conductance heat pipe", Proceeding of the SAREK 2006 Summer Annual Conference, pp. 339-345, 2006.
  6. B. K. Park, G. O. Kim, M. G. Kim, "Analysis of transient thermal characteristics in a gas-loaded heat pipe", Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 13, No. 6, pp. 514-524, 2001.

Cited by

  1. Experimental Study on Heat Transfer Characteristics of Thermosyphon Using Nanofluids vol.36, pp.11, 2012, https://doi.org/10.3795/KSME-B.2012.36.11.1073