DOI QR코드

DOI QR Code

The study on the dimensional stability of digitized dental stone replicas according to difference color of gypsum materials

치과용 모형재 색상에 따른 디지털 모형의 체적 안정성 연구

  • Choi, Seog-Soon (Dept. of Dental Technology, Shingu University) ;
  • Kim, Ki-Baek (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University) ;
  • Lee, Gyeong-Tak (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University) ;
  • Jeon, Jin-Hun (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University) ;
  • Kim, Jae-Hong (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University)
  • 최석순 (신구대학교 치기공과) ;
  • 김기백 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 이경탁 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 전진훈 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김재홍 (고려대학교 대학원 보건과학과 치의기공전공)
  • Received : 2012.09.14
  • Accepted : 2012.12.24
  • Published : 2012.12.30

Abstract

Purpose: The aim of study was to compare the dimensional stability of digitized dental stone replica using different color of gypsum materials using a white light scanner with three-dimensional software. Methods: A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Several type IV stones(white, yellow, green) were used for 30 stone casts(10 casts each) duplicated a master model of mandible. The master model and the replicas were digitized with the non-contacting white light scanner to create 3-dimensional digital models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK) 3D graphic software. One-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}$=0.05). Results: There were considerable differences in mean values between gypsum materials within each color(white, yellow, green), and this difference was statistically significant, p=0.001. Conclusion: Digitization of dental materials on optical scanner was affected by color. Three different color of gypsum materials showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

Keywords

References

  1. Alcan T, Ceylanoglu C, Baysal B. The relationship between digital model accuracy and timedependent deformation of alginate impressions. Angle Orthod, 79(1), 30-36, 2009. https://doi.org/10.2319/100307-475.1
  2. Anusavice KJ. Phillip's science of dental material. 10th ed. Philadelphia. WB Saunders. 1996.
  3. Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J,204(9), 505-511, 2008. https://doi.org/10.1038/sj.bdj.2008.350
  4. Creed B, Chung HK, Jeryl DE, James JX, Lee A. Comparison of the accuracy of linear measurement obtained from cone beam computerized tomography images and digital models. Semin Orthod, 17(2), 49-56, 2011. https://doi.org/10.1053/j.sodo.2010.08.010
  5. Delong R, Pintado MR, Ko CC, Hodges JS, Douglas WH. Factors influencing optical 3D scanning of vinyl polysiloxane impression materials. J Prosth, 10(2), 78-85, 2001. https://doi.org/10.1111/j.1532-849X.2001.00078.x
  6. Delong R, Heinzen M, Hodges JS, Ko CC, Douglas WH. Accuracy of a system for creating 3D computer models of dental arches. J Dent Res, 90(1), 434-440, 2003.
  7. Duke PD, Moore BK, Haug SP, Andres CJ. Study of the physical properties of type IV gypsum, resin-containing and epoxy die materials. J Prosthet Dent, 83(4), 466-473, 2000. https://doi.org/10.1016/S0022-3913(00)70043-6
  8. Finger W, Ohsawa M. Effect of mixing ratio on properties of elastomeric dental impression materials. Dent Mater, 2(4), 183-186, 1986. https://doi.org/10.1016/S0109-5641(86)80033-1
  9. Gerrow JD, Schneider RL. A comparison of the compatibility of elastomeric impression materials, type IV dental stones, and liquid media. J Prothet Dent, 57(3), 292-298, 1987. https://doi.org/10.1016/0022-3913(87)90300-3
  10. Linke BA, Nicholls JI, Faucher RR. Distortion analysis of stone casts made from impression materials. J Prothet Dent, 54(6), 794-802, 1985. https://doi.org/10.1016/0022-3913(85)90473-1
  11. Luthardt RG, Walter MH, Weber A, Koch R, Rudolph H. Clinical parameters influencing the accuracy of 1- and 2- stage impressions: a randomized controlled trial. Int J Prosthodont, 21(4), 322-327, 2008.
  12. Millstein PL. Determining the accuracy of gypsum casts made from Type IV dental stone. J Oral Rehabil, 19(3), 239-243, 1992. https://doi.org/10.1111/j.1365-2842.1992.tb01098.x
  13. Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y. A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J, 28(1), 44-56, 2009. https://doi.org/10.4012/dmj.28.44
  14. Raberin M, Laumon B, Martin J, Brunner F. Dimensions and form of dental arches in subjects with normal occlusions. Am J Orthod Dentofac Orthop, 104(1), 67-72, 1993. https://doi.org/10.1016/0889-5406(93)70029-N
  15. Rekow ED. High-technology innovations and limitations for restorative dentistry. Dent Clin North Am, 37(2), 513-524, 1993.
  16. Rodriguez JM, Curtis RV, Bartlett DW. Surface roughness of impression materials and dental stones scanned by non-contacting laser profilometry. Dent Mater, 25(4), 500-505, 2009. https://doi.org/10.1016/j.dental.2008.10.003
  17. Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ. Comparison of measurements made on digital and plster models. Am J Orthod Dentofac Orthop, 124(1), 101-105, 2003. https://doi.org/10.1016/S0889-5406(03)00152-5
  18. Zilberman O, Huggare JA, Parikakis KA. Evaluation of the validity of tooth size and arch width measurements using conventional and threedimensional virtual orthodontic models. Angle Orthod, 73(3), 301-306, 2003.

Cited by

  1. 구강 내 스캐닝 방법에 의해 제작된 폴리우레탄 모형의 정확도 평가 vol.36, pp.2, 2014, https://doi.org/10.14347/kadt.2014.36.2.91