참고문헌
- Arand M, Hartwig E, Kinzl L, Gebhard F : Spinal navigation in tumor surgery of the thoracic spine : first clinical results. Clin Orthop Relat Res : 211-218, 2002
- Arand M, Schempf M, Hebold D, Teller S, Kinzl L, Gebhard F : [Precision of navigation-assisted surgery of the thoracic and lumbar spine]. Unfallchirurg 106 : 899-906, 2003
- Austin MS, Vaccaro AR, Brislin B, Nachwalter R, Hilibrand AS, Albert TJ : Image-guided spine surgery : a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Spine (Phila Pa 1976) 27 : 2503-2508, 2002 https://doi.org/10.1097/00007632-200211150-00015
- Bolger C, Wigfield C : Image-guided surgery : applications to the cervical and thoracic spine and a review of the first 120 procedures. J Neurosurg 92 : 175-180, 2000
- Choi WW, Green BA, Levi AD : Computer-assisted fluoroscopic targeting system for pedicle screw insertion. Neurosurgery 47 : 872-878, 2000 https://doi.org/10.1097/00006123-200010000-00017
- Diffey BL : The risk of skin cancer from occupational exposure to ultraviolet radiation in hospitals. Phys Med Biol 33 : 1187-1193, 1988 https://doi.org/10.1088/0031-9155/33/10/007
- Foley KT, Smith MM : Image-guided spine surgery. Neurosurg Clin N Am 7 : 171-186, 1996
- Fu TS, Wong CB, Tsai TT, Liang YC, Chen LH, Chen WJ : Pedicle screw insertion : computed tomography versus fluoroscopic image guidance. Int Orthop 32 : 517-521, 2008 https://doi.org/10.1007/s00264-007-0358-1
- Gertzbein SD, Robbins SE : Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15 : 11-14, 1990 https://doi.org/10.1097/00007632-199001000-00004
- Grob D, Magerl F, McGowan DP : Spinal pedicle fixation : reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976) 15 : 251, 1990 https://doi.org/10.1097/00007632-199003000-00024
- Hallquist A, Hardell L, Degerman A, Wingren G, Boquist L : Medical diagnostic and therapeutic ionizing radiation and the risk for thyroid cancer : a case-control study. Eur J Cancer Prev 3 : 259-267, 1994 https://doi.org/10.1097/00008469-199403030-00004
- Hallquist A, Näsman A : Medical diagnostic X-ray radiation--an evaluation from medical records and dentist cards in a case-control study of thyroid cancer in the northern medical region of Sweden. Eur J Cancer Prev 10 : 147-152, 2001 https://doi.org/10.1097/00008469-200104000-00005
- Jaiswal A, Shetty AP, Rajasekaran S : Role of intraoperative Iso-C based navigation in challenging spine trauma. Indian J Orthop 41 : 312-317, 2007 https://doi.org/10.4103/0019-5413.36993
- Jones DP, Robertson PA, Lunt B, Jackson SA : Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine. Spine (Phila Pa 1976) 25 : 1538-1541, 2000 https://doi.org/10.1097/00007632-200006150-00013
- Kosmopoulos V, Schizas C : Pedicle screw placement accuracy : a metaanalysis. Spine (Phila Pa 1976) 32 : E111-E120, 2007 https://doi.org/10.1097/01.brs.0000254048.79024.8b
- Linet MS, Kim KP, Miller DL, Kleinerman RA, Simon SL, Berrington de Gonzalez A : Historical review of occupational exposures and cancer risks in medical radiation workers. Radiat Res 174 : 793-808, 2010 https://doi.org/10.1667/RR2014.1
- Magerl FP : Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res : 125-141, 1984
- Merloz P, Troccaz J, Vouaillat H, Vasile C, Tonetti J, Eid A, et al. : Fluoroscopy- based navigation system in spine surgery. Proc Inst Mech Eng H 221 : 813-820, 2007
- Mirza SK, Wiggins GC, Kuntz C 4th, York JE, Bellabarba C, Knonodi MA, et al. : Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance : a cadaver study. Spine (Phila Pa 1976) 28 : 402-413, 2003
- Nolte LP, Slomczykowski MA, Berlemann U, Strauss MJ, Hofstetter R, Schlenzka D, et al. : A new approach to computer-aided spine surgery : fluoroscopy-based surgical navigation. Eur Spine J 9 Suppl 1 : S78-S88, 2000 https://doi.org/10.1007/PL00010026
- Roessler K, Ungersboeck K, Dietrich W, Aichholzer M, Hittmeir K, Matula C, et al. : Frameless stereotactic guided neurosurgery : clinical experience with an infrared based pointer device navigation system. Acta Neurochir (Wien) 139 : 551-559, 1997 https://doi.org/10.1007/BF02750999
- Schonfeld SJ, Lee C, Berrington de González A : Medical exposure to radiation and thyroid cancer. Clin Oncol (R Coll Radiol) 23 : 244-250, 2011 https://doi.org/10.1016/j.clon.2011.01.159
- Silbermann J, Riese F, Allam Y, Reichert T, Koeppert H, Gutberlet M : Computer tomography assessment of pedicle screw placement in lumbar and sacral spine : comparison between free-hand and O-arm based navigation techniques. Eur Spine J 20 : 875-881, 2011 https://doi.org/10.1007/s00586-010-1683-4
- Simpson AK, Whang PG, Jonisch A, Haims A, Grauer JN : The radiation exposure associated with cervical and lumbar spine radiographs. J Spinal Disord Tech 21 : 409-412, 2008 https://doi.org/10.1097/BSD.0b013e3181568656
- Singer CM, Baraff LJ, Benedict SH, Weiss EL, Singer BD : Exposure of emergency medicine personnel to ionizing radiation during cervical spine radiography. Ann Emerg Med 18 : 822-825, 1989 https://doi.org/10.1016/S0196-0644(89)80204-5
- Tian NF, Xu HZ : Image-guided pedicle screw insertion accuracy : a meta-analysis. Int Orthop 33 : 895-903, 2009 https://doi.org/10.1007/s00264-009-0792-3
- Tjardes T, Shafizadeh S, Rixen D, Paffrath T, Bouillon B, Steinhausen ES, et al. : Image-guided spine surgery : state of the art and future directions. Eur Spine J 19 : 25-45, 2010 https://doi.org/10.1007/s00586-009-1091-9
- van de Kraats EB, van Walsum T, Kendrick L, Noordhoek NJ, Niessen WJ : Accuracy evaluation of direct navigation with an isocentric 3D rotational X-ray system. Med Image Anal 10 : 113-124, 2006 https://doi.org/10.1016/j.media.2005.04.012
- Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S : Spinal pedicle fixation : reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976) 13 : 1012-1018, 1988 https://doi.org/10.1097/00007632-198809000-00008
- Xu R, Ebraheim NA, Ou Y, Yeasting RA : Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique. Spine (Phila Pa 1976) 23 : 1065-1068, 1998 https://doi.org/10.1097/00007632-199805010-00021
- Yang YL, Zhou DS, He JL : Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for C1 Lateral Mass and C2 Pedicle Screw Placement for Atlantoaxial Instability. J Spinal Disord Tech, 2011 [Epub ahead of print]
피인용 문헌
- The accuracy of pedicle screw placement using intraoperative image guidance systems : A systematic review vol.20, pp.2, 2012, https://doi.org/10.3171/2013.11.spine13413
- A novel screw guiding method with a screw guide template system for posterior C-2 fixation : Clinical article vol.21, pp.2, 2012, https://doi.org/10.3171/2014.3.spine13730
- Accuracy of Pedicle Screw Insertion Using Fluoroscopy-Based Navigation-Assisted Surgery : Computed Tomography Postoperative Assessment in 96 Consecutive Patients vol.56, pp.1, 2012, https://doi.org/10.3340/jkns.2014.56.1.16
- Intraoperative image-guided spinal navigation: technical pitfalls and their avoidance vol.36, pp.3, 2014, https://doi.org/10.3171/2014.1.focus13516
- Instrumenting the small thoracic pedicle: the role of intraoperative computed tomography image-guided surgery vol.36, pp.3, 2012, https://doi.org/10.3171/2014.1.focus13527
- Position and complications of pedicle screw insertion with or without image-navigation techniques in the thoracolumbar spine: a meta-analysis of comparative studies vol.28, pp.3, 2012, https://doi.org/10.7555/jbr.28.20130159
- Combining C-arm CT with a new remote operated positioning and guidance system for guidance of minimally invasive spine interventions vol.7, pp.4, 2012, https://doi.org/10.1136/neurintsurg-2013-011034
- Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: a meta-analysis vol.39, pp.3, 2012, https://doi.org/10.1007/s10143-015-0679-2
- The Superiority of Intraoperative O-arm Navigation-assisted Surgery in Instrumenting Extremely Small Thoracic Pedicles of Adolescent Idiopathic Scoliosis : A Case-Control Study vol.95, pp.18, 2012, https://doi.org/10.1097/md.0000000000003581
- The Use of Intraoperative CT and Navigation for the Treatment of Spinal Deformity in Open and Minimally Invasive Surgery vol.42, pp.None, 2012, https://doi.org/10.1097/brs.0000000000002038
- Advantages and Disadvantages of Multi-axis Intraoperative Angiography Unit for Percutaneous Pedicle Screw Placement in the Lumbar Spine vol.57, pp.9, 2012, https://doi.org/10.2176/nmc.oa.2017-0059
- Comparison of intraoperative O-arm- and conventional fluoroscopy (C-arm)-assisted insertion of pedicle screws in the treatment of fracture of thoracic vertebrae vol.25, pp.1, 2012, https://doi.org/10.1177/2309499016684090
- Differences between Manufacturers of Computed Tomography–Based Computer-Assisted Surgery Systems Do Exist : A Systematic Literature Review vol.7, pp.1, 2017, https://doi.org/10.1055/s-0036-1583942
- POSTEROLATERAL, POSTERIOR AND MI-TRANSFORAMINAL LUMBAR INTERBODY FUSION: A STUDY OF 212 CASES vol.17, pp.1, 2012, https://doi.org/10.1590/s1808-185120181701175723
- Pedicle Screw Insertion Accuracy Using O-Arm, Robotic Guidance, or Freehand Technique: A Comparative Study vol.43, pp.6, 2018, https://doi.org/10.1097/brs.0000000000002449
- Time Demand and Radiation Dose in 3D-Fluoroscopy-based Navigation-assisted 3D-Fluoroscopy-controlled Pedicle Screw Instrumentations vol.43, pp.9, 2012, https://doi.org/10.1097/brs.0000000000002422
- Pedicle Screw Insertion: Is O-Arm–Based Navigation Superior to the Conventional Freehand Technique? A Systematic Review and Meta-Analysis vol.144, pp.None, 2020, https://doi.org/10.1016/j.wneu.2020.07.205
- Augmented reality navigation with intraoperative 3D imaging vs fluoroscopy-assisted free-hand surgery for spine fixation surgery: a matched-control study comparing accuracy vol.10, pp.None, 2012, https://doi.org/10.1038/s41598-020-57693-5
- Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures compared with open technique vol.65, pp.1, 2012, https://doi.org/10.23736/s0390-5616.18.04439-9
- Deep learning‐based X‐ray inpainting for improving spinal 2D‐3D registration vol.17, pp.2, 2021, https://doi.org/10.1002/rcs.2228