References
- Heit JA. Venous thromboembolism epidemiology: implications for prevention and management. Semin Thromb Hemost 2002;28 Suppl 2:3-13
- Greenfield LJ, Michna BA. Twelve-year clinical experience with the Greenfield vena caval filter. Surgery 1988;104:706-712
- Pais SO, Tobin KD, Austin CB, Queral L. Percutaneous insertion of the Greenfield inferior vena cava filter: experience with ninety-six patients. J Vasc Surg 1988;8:460-464
- Becker DM, Philbrick JT, Selby JB. Inferior vena cava filters. Indications, safety, effectiveness. Arch Intern Med 1992;152:1985-1994 https://doi.org/10.1001/archinte.1992.00400220023005
- Liu WC, Do YS, Choo SW, Kim DI, Kim YW, Kim DK, et al. The mid-term efficacy and safety of a permanent nitinol IVC filter (TrapEase). Korean J Radiol 2005;6:110-116 https://doi.org/10.3348/kjr.2005.6.2.110
- Kinney TB. Update on inferior vena cava filters. J Vasc Interv Radiol 2003;14:425-440 https://doi.org/10.1097/01.RVI.0000064860.87207.77
- Berczi V, Bottomley JR, Thomas SM, Taneja S, Gaines PA, Cleveland TJ. Long-term retrievability of IVC filters: should we abandon permanent devices? Cardiovasc Intervent Radiol 2007;30:820-827 https://doi.org/10.1007/s00270-007-9153-z
- PREPIC Study Group. Eight-year follow-up of patients with permanent vena cava filters in the prevention of pulmonary embolism: the PREPIC (Prevention du Risque d'Embolie Pulmonaire par Interruption Cave) randomized study. Circulation 2005;112:416-422 https://doi.org/10.1161/CIRCULATIONAHA.104.512834
- Looby S, Given MF, Geoghegan T, McErlean A, Lee MJ. Gunther Tulip retrievable inferior vena caval filters: indications, efficacy, retrieval, and complications. Cardiovasc Intervent Radiol 2007;30:59-65 https://doi.org/10.1007/s00270-006-0093-9
- Wicky S, Doenz F, Meuwly JY, Portier F, Schnyder P, Denys A. Clinical experience with retrievable Günther Tulip vena cava filters. J Endovasc Ther 2003;10:994-1000 https://doi.org/10.1583/1545-1550(2003)010<0994:CEWRGT>2.0.CO;2
- Rosenthal D, Wellons ED, Hancock SM, Burkett AB. Retrievability of the Günther Tulip vena cava filter after dwell times longer than 180 days in patients with multiple trauma. J Endovasc Ther 2007;14:406-410 https://doi.org/10.1583/06-2045.1
- Hoppe H, Nutting CW, Smouse HR, Vesely TM, Pohl C, Bettmann MA, et al. Gunther Tulip filter retrievability multicenter study including CT follow-up: final report. J Vasc Interv Radiol 2006;17:1017-1023 https://doi.org/10.1097/01.RVI.90000223689.49091.76
- Lopera JE, Araki JU, Kirsch D, Qian Z, Brazzini A, Gonzalez A, et al. A modified technique to minimize filter tilting during deployment of the Günther Tulip filter: in vitro study. J Vasc Interv Radiol 2005;16:1539-1544 https://doi.org/10.1097/01.RVI.0000177969.33404.16
- Van Ha TG, Vinokur O, Lorenz J, Regalado S, Zangan S, Piano G, et al. Techniques used for difficult retrievals of the Günther Tulip inferior vena cava filter: experience in 32 patients. J Vasc Interv Radiol 2009;20:92-99 https://doi.org/10.1016/j.jvir.2008.10.007
- Joels CS, Sing RF, Heniford BT. Complications of inferior vena cava filters. Am Surg 2003;69:654-659
- Kinney TB, Rose SC. Regarding "Limb asymmetry in titanium Greenfield filters: clinically significant?". J Vasc Surg 1998;27:1193-1194
- Neuerburg J, Günther RW, Rassmussen E, Vorwerk D, Tonn K, Handt S, et al. New retrievable percutaneous vena cava filter: experimental in vitro and in vivo evaluation. Cardiovasc Intervent Radiol 1993;16:224-229 https://doi.org/10.1007/BF02602965
- Terhaar OA, Lyon SM, Given MF, Foster AE, Mc Grath F, Lee MJ. Extended interval for retrieval of Günther Tulip filters. J Vasc Interv Radiol 2004;15:1257-1262 https://doi.org/10.1097/01.RVI.0000134497.50590.E2
- Sag AA, Stavas JM, Burke CT, Dixon RG, Marquess JS, Mauro MA. Analysis of tilt of the Gunther Tulip filter. J Vasc Interv Radiol 2008;19:669-676 https://doi.org/10.1016/j.jvir.2008.01.020
- Seo TS, Cha IH, Park CM, Kim KA, Lee CH, Choi JW, et al. Detection and correction of anterior or posterior tilting of the Günther-Tulip filter in the inferior vena cava and correction by repositioning: a phantom study and preliminary clinical experiences. J Vasc Interv Radiol 2007;18:427-436 https://doi.org/10.1016/j.jvir.2007.01.003
Cited by
- Introducer curving technique to reduce tilting of transfemoral Günther Tulip IVC filter: in vitro study vol.53, pp.7, 2012, https://doi.org/10.1258/ar.2012.110722
- Medical literature, vena cava filters and evidence of efficacy : A descriptive review vol.111, pp.4, 2012, https://doi.org/10.1160/th13-07-0601
- Filter tilting and retrievability of the Celect and Denali inferior vena cava filters using propensity score-matching analysis vol.5, pp.None, 2012, https://doi.org/10.1016/j.ejro.2018.09.001
- Over-the-wire deployment techniques of option elite inferior vena cava filter: 3D printing vena cava phantom study vol.7, pp.None, 2012, https://doi.org/10.1016/j.ejro.2020.100227